Loading…

An Arbitrary Waveform Wearable Neuro-stimulator System for Neurophysiology Research on Freely Behaving Animals

Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with...

Full description

Saved in:
Bibliographic Details
Published in:Journal of medical signals and sensors 2014-04, Vol.4 (2), p.94-102
Main Authors: Samani, Mohsen Mosayebi, Mahnam, Amin, Hosseini, Nasrin
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3778-8330a38ec9fe03b566006a3f91c5ff48ed09df26aed9a4bf412a843c02bb050d3
cites cdi_FETCH-LOGICAL-c3778-8330a38ec9fe03b566006a3f91c5ff48ed09df26aed9a4bf412a843c02bb050d3
container_end_page 102
container_issue 2
container_start_page 94
container_title Journal of medical signals and sensors
container_volume 4
creator Samani, Mohsen Mosayebi
Mahnam, Amin
Hosseini, Nasrin
description Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro-stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor-based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra-low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 μA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 μA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long-term experiments in the field of cognitive and neuroscience research.
doi_str_mv 10.4103/2228-7477.130198
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_f3b4be3bc1024a88b88dd9ecc7c3bc92</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_f3b4be3bc1024a88b88dd9ecc7c3bc92</doaj_id><sourcerecordid>1519257875</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3778-8330a38ec9fe03b566006a3f91c5ff48ed09df26aed9a4bf412a843c02bb050d3</originalsourceid><addsrcrecordid>eNpVUU1v1DAQjRCIVqV3TshHLin-SmxfkJaKQqUKJD7Uo2U7411XSbzYyUr593hJWbW-jPXmvTejeVX1luArTjD7QCmVteBCXBGGiZIvqvMT9PLJ_6y6zPkBl9c2mGD1ujqjXLSECXZejZsRbZINUzJpQffmAD6mAd2DScb2gL7BnGKdpzDMvZliQj-XPMGACmvt7XdLDrGP2wX9gFxkbofiiG4SQL-gT7AzhzBu0WYMg-nzm-qVLwUuH-tF9fvm86_rr_Xd9y-315u72jEhZC0Zw4ZJcMoDZrZp27K8YV4R13jPJXRYdZ62BjpluPWcUCM5c5haixvcsYvqdvXtonnQ-1SGp0VHE_Q_IKatNmkKrgftmeUWmHUEU26ktFJ2nQLnhCugosXr4-q1n-0AnYOxHKt_Zvq8M4ad3saDZkpxQUkxeP9okOKfGfKkh5Ad9L0ZIc5Zk4Yo2ggpmkLFK9WlmHMCfxpDsD6mro-x6mOsek29SN49Xe8k-J8x-wvaXqpR</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1519257875</pqid></control><display><type>article</type><title>An Arbitrary Waveform Wearable Neuro-stimulator System for Neurophysiology Research on Freely Behaving Animals</title><source>PubMed Central</source><creator>Samani, Mohsen Mosayebi ; Mahnam, Amin ; Hosseini, Nasrin</creator><creatorcontrib>Samani, Mohsen Mosayebi ; Mahnam, Amin ; Hosseini, Nasrin</creatorcontrib><description>Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro-stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor-based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra-low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 μA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 μA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long-term experiments in the field of cognitive and neuroscience research.</description><identifier>ISSN: 2228-7477</identifier><identifier>EISSN: 2228-7477</identifier><identifier>DOI: 10.4103/2228-7477.130198</identifier><identifier>PMID: 24761373</identifier><language>eng</language><publisher>India: Medknow Publications &amp; Media Pvt Ltd</publisher><subject>Electrical stimulation ; neurophysiology ; Original ; programmable current stimulator ; ultra-low power</subject><ispartof>Journal of medical signals and sensors, 2014-04, Vol.4 (2), p.94-102</ispartof><rights>Copyright: © Journal of Medical Signals and Sensors 2014</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3778-8330a38ec9fe03b566006a3f91c5ff48ed09df26aed9a4bf412a843c02bb050d3</citedby><cites>FETCH-LOGICAL-c3778-8330a38ec9fe03b566006a3f91c5ff48ed09df26aed9a4bf412a843c02bb050d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994721/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3994721/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24761373$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Samani, Mohsen Mosayebi</creatorcontrib><creatorcontrib>Mahnam, Amin</creatorcontrib><creatorcontrib>Hosseini, Nasrin</creatorcontrib><title>An Arbitrary Waveform Wearable Neuro-stimulator System for Neurophysiology Research on Freely Behaving Animals</title><title>Journal of medical signals and sensors</title><addtitle>J Med Signals Sens</addtitle><description>Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro-stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor-based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra-low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 μA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 μA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long-term experiments in the field of cognitive and neuroscience research.</description><subject>Electrical stimulation</subject><subject>neurophysiology</subject><subject>Original</subject><subject>programmable current stimulator</subject><subject>ultra-low power</subject><issn>2228-7477</issn><issn>2228-7477</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVUU1v1DAQjRCIVqV3TshHLin-SmxfkJaKQqUKJD7Uo2U7411XSbzYyUr593hJWbW-jPXmvTejeVX1luArTjD7QCmVteBCXBGGiZIvqvMT9PLJ_6y6zPkBl9c2mGD1ujqjXLSECXZejZsRbZINUzJpQffmAD6mAd2DScb2gL7BnGKdpzDMvZliQj-XPMGACmvt7XdLDrGP2wX9gFxkbofiiG4SQL-gT7AzhzBu0WYMg-nzm-qVLwUuH-tF9fvm86_rr_Xd9y-315u72jEhZC0Zw4ZJcMoDZrZp27K8YV4R13jPJXRYdZ62BjpluPWcUCM5c5haixvcsYvqdvXtonnQ-1SGp0VHE_Q_IKatNmkKrgftmeUWmHUEU26ktFJ2nQLnhCugosXr4-q1n-0AnYOxHKt_Zvq8M4ad3saDZkpxQUkxeP9okOKfGfKkh5Ad9L0ZIc5Zk4Yo2ggpmkLFK9WlmHMCfxpDsD6mro-x6mOsek29SN49Xe8k-J8x-wvaXqpR</recordid><startdate>20140401</startdate><enddate>20140401</enddate><creator>Samani, Mohsen Mosayebi</creator><creator>Mahnam, Amin</creator><creator>Hosseini, Nasrin</creator><general>Medknow Publications &amp; Media Pvt Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20140401</creationdate><title>An Arbitrary Waveform Wearable Neuro-stimulator System for Neurophysiology Research on Freely Behaving Animals</title><author>Samani, Mohsen Mosayebi ; Mahnam, Amin ; Hosseini, Nasrin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3778-8330a38ec9fe03b566006a3f91c5ff48ed09df26aed9a4bf412a843c02bb050d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Electrical stimulation</topic><topic>neurophysiology</topic><topic>Original</topic><topic>programmable current stimulator</topic><topic>ultra-low power</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Samani, Mohsen Mosayebi</creatorcontrib><creatorcontrib>Mahnam, Amin</creatorcontrib><creatorcontrib>Hosseini, Nasrin</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>Journal of medical signals and sensors</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Samani, Mohsen Mosayebi</au><au>Mahnam, Amin</au><au>Hosseini, Nasrin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An Arbitrary Waveform Wearable Neuro-stimulator System for Neurophysiology Research on Freely Behaving Animals</atitle><jtitle>Journal of medical signals and sensors</jtitle><addtitle>J Med Signals Sens</addtitle><date>2014-04-01</date><risdate>2014</risdate><volume>4</volume><issue>2</issue><spage>94</spage><epage>102</epage><pages>94-102</pages><issn>2228-7477</issn><eissn>2228-7477</eissn><abstract>Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro-stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor-based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra-low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 μA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 μA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long-term experiments in the field of cognitive and neuroscience research.</abstract><cop>India</cop><pub>Medknow Publications &amp; Media Pvt Ltd</pub><pmid>24761373</pmid><doi>10.4103/2228-7477.130198</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2228-7477
ispartof Journal of medical signals and sensors, 2014-04, Vol.4 (2), p.94-102
issn 2228-7477
2228-7477
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_f3b4be3bc1024a88b88dd9ecc7c3bc92
source PubMed Central
subjects Electrical stimulation
neurophysiology
Original
programmable current stimulator
ultra-low power
title An Arbitrary Waveform Wearable Neuro-stimulator System for Neurophysiology Research on Freely Behaving Animals
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T15%3A12%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20Arbitrary%20Waveform%20Wearable%20Neuro-stimulator%20System%20for%20Neurophysiology%20Research%20on%20Freely%20Behaving%20Animals&rft.jtitle=Journal%20of%20medical%20signals%20and%20sensors&rft.au=Samani,%20Mohsen%20Mosayebi&rft.date=2014-04-01&rft.volume=4&rft.issue=2&rft.spage=94&rft.epage=102&rft.pages=94-102&rft.issn=2228-7477&rft.eissn=2228-7477&rft_id=info:doi/10.4103/2228-7477.130198&rft_dat=%3Cproquest_doaj_%3E1519257875%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3778-8330a38ec9fe03b566006a3f91c5ff48ed09df26aed9a4bf412a843c02bb050d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1519257875&rft_id=info:pmid/24761373&rfr_iscdi=true