Loading…

Cardiac index by thermodilution or transthoracic echocardiography in dogs at different hemodynamic states

Proper monitoring of cardiac index (CI) in critically ill patients requires accurate and minimally invasive methods. The aim of this study was to compare the CI values obtained by thermodilution or echocardiography using different methods in dogs in different hemodynamic states. Nine dogs weighing 1...

Full description

Saved in:
Bibliographic Details
Published in:Ciência rural 2016-11, Vol.46 (11), p.2049-2054
Main Authors: Gehrcke, Martielo Ivan, Cardoso, Helena Mondardo, Regalin, Doughlas, Silva, Gizelli da, Padilha, Vanessa Sasso, Moraes, Aury Nunes de, Oleskovicz, Nilson
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Proper monitoring of cardiac index (CI) in critically ill patients requires accurate and minimally invasive methods. The aim of this study was to compare the CI values obtained by thermodilution or echocardiography using different methods in dogs in different hemodynamic states. Nine dogs weighing 19.6±1.3kg were anesthetized with isoflurane at 1.4V% (Baseline) and subjected to mechanical ventilation (MV),a hypodynamic state (Hypo) with isoflurane at 3.5V% and hyperdynamic state (hyper) with dobutamine infusion at 5μgkg-1min-1. CI analysis was performed by thermodilution (TD) and using the modified Simpson's method, aortic velocity-time integral (A-VTI) method and pulmonary VTI (P-VTI) method. We performed Pearson's correlation and Bland-Altman analysis. The CI values (Lm-2min-1) of the animals in the Baseline, MV, Hypo and Hyper states were 4.3±1, 3.6±0.7, 2.9±0.66 and 6.1±2, for TD; 2.8±0.7, 2.4±0.3, 1.7±0.7 and 4.4±1.2, for Simpson's method; 3.4±0.9, 3.1±0.7, 2.6±3.4, 6.1±1.8 for A-VTI; and 3.6±0.8, 3.6±0.8, 2.7±0.6 and 6.2±1.5, for P-VTI. The CI values using Simpson's method were lower than those obtained by TD in all states, and it was observed a significant correlation in the Hypo (r=0.89) and Hyper (r=0.76) groups. In addition,the percent error in the Hypo group using Simpson's method was 26% relative to TD, which allowed for the identification of the different hemodynamic states. With respect to the other methods and states, there was no agreement or correlation between the methods and TD. We concluded that none of the tested echocardiography methods exhibited acceptable agreement with thermodilution at different hemodynamic states. RESUMO: A adequada monitoração do índice cardíaco (IC) em pacientes críticos requer métodos acurados e minimamente invasivos. O objetivo deste estudo foi comparar o IC obtido por termodiluição ou ecocardiografia em cães sob alterações hemodinâmicas. Utilizaram-se nove cães pesando 19,6±1,3kg, os quais foram anestesiados com isofluoranoa1,4V% (Basal) e submetidos à ventilação mecânica (VM) e estados hipodinâmico (Hipo) com isofluoranoa3,5V% e hiperdinâmico (Hiper), com dobutaminaa5µgkg-1min-1. O IC foi obtido por termodiluição (TD) e pelos métodos ecocardiográficos de Simpson modificado, e pela velocidade em tempo integral (VTI) nas valvas aórtica (VTI-A) e pulmonar (VTI-P). Realizou-se a análise de correlação de Pearson e de concordância de Bland-Altman. O IC (Lm-2min-1) nas fases Basal, VM, Hipo e Hiper foi de 4,3±1, 3
ISSN:1678-4596
0103-8478
1678-4596
DOI:10.1590/0103-8478cr20150352