Clinical Efficacy of Distal Tibial Hounsfield Unit for the Diagnosis of Osteoporosis in Ankle Fractures

Category: Trauma; Ankle Introduction/Purpose: Ankle fracture is one of the most common fractures over the age of 50 years. However, there is a lack of research on osteoporotic ankle fractures compared to other osteoporotic fractures. Recently, some studies have been published that Hounsfield Unit(HU...

Full description

Saved in:
Bibliographic Details
Published in:Foot & ankle orthopaedics 2023-12, Vol.8 (4)
Main Authors: Suh, Jae Wan, Kim, Mingyu, Choi, Sungjoon, Park, Hyun-Woo
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Category: Trauma; Ankle Introduction/Purpose: Ankle fracture is one of the most common fractures over the age of 50 years. However, there is a lack of research on osteoporotic ankle fractures compared to other osteoporotic fractures. Recently, some studies have been published that Hounsfield Unit(HU) measuring bone attenuation from CT scan is used for assessing the bone density of not only the hip and spine but also extremities such as the distal radius and proximal humerus. This study aims to evaluate the correlation between HU of distal tibia without ankle fracture and DEXA-BMD and determine the cut-off value of HU for osteoporosis diagnosis. Additionally, this study determines whether the HU of the distal tibia obtained from the preoperative CT scan of ankle fractures helps evaluate patients with osteoporotic ankle fractures. Methods: From June 2016 to August 2020, We retrospectively studied foot and ankle traumatic patients who are postmenopausal women or men over 50 years. They conducted a foot or ankle CT scan containing the axial images of the distal tibia and DEXA- BMD within three months. Patients with open fractures with severe displacement or arthritic change were excluded. The mean HU was obtained from two sequential axial images of the distal tibial metaphysis's largest region of interest (ROI), more than 1cm proximal to the tibial plafond. We divided the patients into Group A without ankle fractures and Group B with distal tibia or fibula fractures in the ankle. The correlation analysis was done between the distal tibial HU and DEXA-BMD. We obtained the cut-off value of the distal tibial HU for osteoporosis using receiver operating characteristic(ROC) curves and compared the results between the two groups. Results: Group A was 38 cases(mean age 69.9), and Group B was 59 (mean age 71.0). There were no statistical differences in patients' characteristics, the mean distal tibial HU, bone density, T-score, and rate of osteoporosis in BMD. All HU values in both groups showed excellent inter- and intra-observer reliability(All intraclass coefficients>0.9). Both groups had significant correlations between the distal tibial HU and DEXA-BMD, especially in the femur neck and L3 spine(r=0.706, 0.622, p< 0.001 in Group A, r=0.625,0.499, p< 0.001 in Group B). The cut-off value for osteoporosis of the distal tibial HU was 153.15(sensitivity 73.9%, specificity 86.7%; area under the curve(AUC) 0.841, 95% CI 0.716-0.965, p< 0.001) in Group A. The cut-off valu
ISSN:2473-0114
2473-0114
DOI:10.1177/2473011423S00131