STUDY OF SELF-LEVELING PNEUMATIC VIBRATION ISOLATION, PHASE I

Dynamic response is determined for a single mount system by analysis and the use of an analog computer. Both step and sinusoidal inputs of base movement and force on the mass are considered. This air mount system consists only of the isolated mass, the air mount bags, a relatively small booster valv...

Full description

Saved in:
Bibliographic Details
Main Authors: DUCKWALD,C S, COLSTON,J R, BOOTHE,W A
Format: Report
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Dynamic response is determined for a single mount system by analysis and the use of an analog computer. Both step and sinusoidal inputs of base movement and force on the mass are considered. This air mount system consists only of the isolated mass, the air mount bags, a relatively small booster valve, a relatively small leveling valve, an air pressure supply, and the interconnecting piping. (Author)