Fatigue Crack Propagation in an HSLA Steel (MF-80) in Air and in Salt Water
Fatigue crack propagation was studied in MF-80 HSLA steel in ambient room air and in 3.5 percent NaC1 salt water. Region-II fatigue crack growth rate (da/dN) data were obtained at two load ratios, R=0.10 and R = 0.67. da/dN values were found to be affected by both load ratio and environment, with th...
Saved in:
Main Authors: | , |
---|---|
Format: | Report |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Fatigue crack propagation was studied in MF-80 HSLA steel in ambient room air and in 3.5 percent NaC1 salt water. Region-II fatigue crack growth rate (da/dN) data were obtained at two load ratios, R=0.10 and R = 0.67. da/dN values were found to be affected by both load ratio and environment, with the greatest effect being caused by the combination of high load ratio and salt water environment. Overall, the results of this study suggest that MF-80 HSLA steel may have slightly less Region-II fatigue crack propagation resistance than other high-strength steels of comparable strength. |
---|