Loading…

Fatigue Crack Propagation in an HSLA Steel (MF-80) in Air and in Salt Water

Fatigue crack propagation was studied in MF-80 HSLA steel in ambient room air and in 3.5 percent NaC1 salt water. Region-II fatigue crack growth rate (da/dN) data were obtained at two load ratios, R=0.10 and R = 0.67. da/dN values were found to be affected by both load ratio and environment, with th...

Full description

Saved in:
Bibliographic Details
Main Authors: Gill,S J, Crooker,T W
Format: Report
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Fatigue crack propagation was studied in MF-80 HSLA steel in ambient room air and in 3.5 percent NaC1 salt water. Region-II fatigue crack growth rate (da/dN) data were obtained at two load ratios, R=0.10 and R = 0.67. da/dN values were found to be affected by both load ratio and environment, with the greatest effect being caused by the combination of high load ratio and salt water environment. Overall, the results of this study suggest that MF-80 HSLA steel may have slightly less Region-II fatigue crack propagation resistance than other high-strength steels of comparable strength.