Loading…
Air Temperature Shield Tests
Measurements were made with a group of sensors for 37 days at the end of a dock in Vineyard Sound. The sensors included: a thermistor in an R.M. Young aspirated air temperature radiation shield, a thermistor in an R.M. Young multiplate shield, wind speed and direction, and solar irradiance. For the...
Saved in:
Main Author: | |
---|---|
Format: | Report |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Measurements were made with a group of sensors for 37 days at the end of a dock in Vineyard Sound. The sensors included: a thermistor in an R.M. Young aspirated air temperature radiation shield, a thermistor in an R.M. Young multiplate shield, wind speed and direction, and solar irradiance. For the last eight days we also included a WHOI built cylindrical radiation shield. For wind speeds above 2 m/s, the multiplate shield had an RMS error relative to the aspirated shield of 0.2-0.3 C during day-light hours. Adding a correction linear in solar irradiance decreased the error by a factor of one third to one half. The cylindrical shield appears to have performed better than this but there was insufficient data to support this conclusion statistically.
Sponsored in part by Grant NSF-OCE82-11108. |
---|