Residual Stress Changes in Fatigue. Volume 1. Residual Stress Measurements by X-Ray Diffraction in Notched Test Specimens
An experimental setup is described for performing stress measurements on notched test specimens under load using a TEC series 1600 x-ray diffraction system. Excellent results are being obtained for Ti-6Al-4V material, but measurements on 7475-t651 Al are complicated by a texturing problem. Also, som...
Saved in:
Main Authors: | , |
---|---|
Format: | Report |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | An experimental setup is described for performing stress measurements on notched test specimens under load using a TEC series 1600 x-ray diffraction system. Excellent results are being obtained for Ti-6Al-4V material, but measurements on 7475-t651 Al are complicated by a texturing problem. Also, some unusual effects are observed during plastic deformation which are not yet understood. The performance of the x-ray diffraction system is found to be quite good in general, but some minor problems are noted.
See also Volume 2, ADA208346. |
---|