Minimum Release of Tributyltin to Prevent Macrofouling

The minimum release of tri-and dibutyltin has been determined for both barnacles and hydrozoans. The test method involved perfusing a known flux of biocide through a polycarbonate membrane filter with the downstream surface of the membrane exposed to a natural population of fouling organisms. No min...

Full description

Saved in:
Bibliographic Details
Main Authors: Mihm, James W, Loeb, George I, Haslbeck, Elizabeth G
Format: Report
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The minimum release of tri-and dibutyltin has been determined for both barnacles and hydrozoans. The test method involved perfusing a known flux of biocide through a polycarbonate membrane filter with the downstream surface of the membrane exposed to a natural population of fouling organisms. No minimum release could be calculated for the dibutyltin because the flux rates were not high enough to achieve a zero fouling condition.