Design, Develop, Fabricate, Test and Deliver a Protoflight Medium-To-High-Energy Electron Detector for Integration into a Small On-Board Diagnostic Sensors Package
An electron spectrometer has been designed to measure electron flux in the range of 3 to 30 MeV. A breadboard unit was designed and tested, using a solid state detector telescope for geometric factor definition and a Cerenkov radiator/PMT for energy measurement. The measured response to electrons wa...
Saved in:
Main Authors: | , , |
---|---|
Format: | Report |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | |
container_title | |
container_volume | |
creator | Belue, Jeffrey E Hanser, Frederick A Morel, Paul R |
description | An electron spectrometer has been designed to measure electron flux in the range of 3 to 30 MeV. A breadboard unit was designed and tested, using a solid state detector telescope for geometric factor definition and a Cerenkov radiator/PMT for energy measurement. The measured response to electrons was very broad, so the Cerenkov radiator was redesigned as a larger volume with larger PMTs to improve the energy resolution. The modified Cerenkov radiator/PMT assembly was tested, and a protoflight unit is being fabricated. The protoflight electron spectrometer was originally scheduled to be integrated to the Small Onboard Environmental Diagnostic Sensors (SOBEDS) Package, but this has been canceled. The protoflight is mostly complete, except for the spacecraft electrical interface design, which is on hold until a spacecraft interface is specified. |
format | report |
fullrecord | <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA416913</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA416913</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA4169133</originalsourceid><addsrcrecordid>eNqFjTFOA0EMRbehQMANKHyAnSIKQkqZsBuFAhEp20dm1zuxmNjIYyJxHi6Ki_QUlv_X8_--bX47qpylhY4uVPSrhS1-GI_o1MJA1QFlClj4QgYIe1PXuXA-ObzRxN_nNGjahU-9kOUf6AuNbioR8lBqMMe8ilM2dA7A4hpVhzOWAu-SNooWPxizaHUe4UBS1SrscfzETPfNzYyl0sN13zWP23542aUpjo-REPLjuls_LZ5Xi-XyH_wHTeJRLw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Design, Develop, Fabricate, Test and Deliver a Protoflight Medium-To-High-Energy Electron Detector for Integration into a Small On-Board Diagnostic Sensors Package</title><source>DTIC Technical Reports</source><creator>Belue, Jeffrey E ; Hanser, Frederick A ; Morel, Paul R</creator><creatorcontrib>Belue, Jeffrey E ; Hanser, Frederick A ; Morel, Paul R ; PANAMETRICS INC WALTHAM MA</creatorcontrib><description>An electron spectrometer has been designed to measure electron flux in the range of 3 to 30 MeV. A breadboard unit was designed and tested, using a solid state detector telescope for geometric factor definition and a Cerenkov radiator/PMT for energy measurement. The measured response to electrons was very broad, so the Cerenkov radiator was redesigned as a larger volume with larger PMTs to improve the energy resolution. The modified Cerenkov radiator/PMT assembly was tested, and a protoflight unit is being fabricated. The protoflight electron spectrometer was originally scheduled to be integrated to the Small Onboard Environmental Diagnostic Sensors (SOBEDS) Package, but this has been canceled. The protoflight is mostly complete, except for the spacecraft electrical interface design, which is on hold until a spacecraft interface is specified.</description><language>eng</language><subject>Atomic and Molecular Physics and Spectroscopy ; BREADBOARD MODELS ; CERENKOV RADIATION ; COSMIC RAYS ; DETECTORS ; ELECTRON FLUX ; ELECTRON SPECTROSCOPY ; ONBOARD ; SPACECRAFT ; SPECTROMETERS ; Unmanned Spacecraft ; WUAFRL2822GCPM</subject><creationdate>2003</creationdate><rights>APPROVED FOR PUBLIC RELEASE</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,780,885,27567,27568</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA416913$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Belue, Jeffrey E</creatorcontrib><creatorcontrib>Hanser, Frederick A</creatorcontrib><creatorcontrib>Morel, Paul R</creatorcontrib><creatorcontrib>PANAMETRICS INC WALTHAM MA</creatorcontrib><title>Design, Develop, Fabricate, Test and Deliver a Protoflight Medium-To-High-Energy Electron Detector for Integration into a Small On-Board Diagnostic Sensors Package</title><description>An electron spectrometer has been designed to measure electron flux in the range of 3 to 30 MeV. A breadboard unit was designed and tested, using a solid state detector telescope for geometric factor definition and a Cerenkov radiator/PMT for energy measurement. The measured response to electrons was very broad, so the Cerenkov radiator was redesigned as a larger volume with larger PMTs to improve the energy resolution. The modified Cerenkov radiator/PMT assembly was tested, and a protoflight unit is being fabricated. The protoflight electron spectrometer was originally scheduled to be integrated to the Small Onboard Environmental Diagnostic Sensors (SOBEDS) Package, but this has been canceled. The protoflight is mostly complete, except for the spacecraft electrical interface design, which is on hold until a spacecraft interface is specified.</description><subject>Atomic and Molecular Physics and Spectroscopy</subject><subject>BREADBOARD MODELS</subject><subject>CERENKOV RADIATION</subject><subject>COSMIC RAYS</subject><subject>DETECTORS</subject><subject>ELECTRON FLUX</subject><subject>ELECTRON SPECTROSCOPY</subject><subject>ONBOARD</subject><subject>SPACECRAFT</subject><subject>SPECTROMETERS</subject><subject>Unmanned Spacecraft</subject><subject>WUAFRL2822GCPM</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>2003</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNqFjTFOA0EMRbehQMANKHyAnSIKQkqZsBuFAhEp20dm1zuxmNjIYyJxHi6Ki_QUlv_X8_--bX47qpylhY4uVPSrhS1-GI_o1MJA1QFlClj4QgYIe1PXuXA-ObzRxN_nNGjahU-9kOUf6AuNbioR8lBqMMe8ilM2dA7A4hpVhzOWAu-SNooWPxizaHUe4UBS1SrscfzETPfNzYyl0sN13zWP23542aUpjo-REPLjuls_LZ5Xi-XyH_wHTeJRLw</recordid><startdate>20030418</startdate><enddate>20030418</enddate><creator>Belue, Jeffrey E</creator><creator>Hanser, Frederick A</creator><creator>Morel, Paul R</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>20030418</creationdate><title>Design, Develop, Fabricate, Test and Deliver a Protoflight Medium-To-High-Energy Electron Detector for Integration into a Small On-Board Diagnostic Sensors Package</title><author>Belue, Jeffrey E ; Hanser, Frederick A ; Morel, Paul R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA4169133</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Atomic and Molecular Physics and Spectroscopy</topic><topic>BREADBOARD MODELS</topic><topic>CERENKOV RADIATION</topic><topic>COSMIC RAYS</topic><topic>DETECTORS</topic><topic>ELECTRON FLUX</topic><topic>ELECTRON SPECTROSCOPY</topic><topic>ONBOARD</topic><topic>SPACECRAFT</topic><topic>SPECTROMETERS</topic><topic>Unmanned Spacecraft</topic><topic>WUAFRL2822GCPM</topic><toplevel>online_resources</toplevel><creatorcontrib>Belue, Jeffrey E</creatorcontrib><creatorcontrib>Hanser, Frederick A</creatorcontrib><creatorcontrib>Morel, Paul R</creatorcontrib><creatorcontrib>PANAMETRICS INC WALTHAM MA</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Belue, Jeffrey E</au><au>Hanser, Frederick A</au><au>Morel, Paul R</au><aucorp>PANAMETRICS INC WALTHAM MA</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Design, Develop, Fabricate, Test and Deliver a Protoflight Medium-To-High-Energy Electron Detector for Integration into a Small On-Board Diagnostic Sensors Package</btitle><date>2003-04-18</date><risdate>2003</risdate><abstract>An electron spectrometer has been designed to measure electron flux in the range of 3 to 30 MeV. A breadboard unit was designed and tested, using a solid state detector telescope for geometric factor definition and a Cerenkov radiator/PMT for energy measurement. The measured response to electrons was very broad, so the Cerenkov radiator was redesigned as a larger volume with larger PMTs to improve the energy resolution. The modified Cerenkov radiator/PMT assembly was tested, and a protoflight unit is being fabricated. The protoflight electron spectrometer was originally scheduled to be integrated to the Small Onboard Environmental Diagnostic Sensors (SOBEDS) Package, but this has been canceled. The protoflight is mostly complete, except for the spacecraft electrical interface design, which is on hold until a spacecraft interface is specified.</abstract><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | |
ispartof | |
issn | |
language | eng |
recordid | cdi_dtic_stinet_ADA416913 |
source | DTIC Technical Reports |
subjects | Atomic and Molecular Physics and Spectroscopy BREADBOARD MODELS CERENKOV RADIATION COSMIC RAYS DETECTORS ELECTRON FLUX ELECTRON SPECTROSCOPY ONBOARD SPACECRAFT SPECTROMETERS Unmanned Spacecraft WUAFRL2822GCPM |
title | Design, Develop, Fabricate, Test and Deliver a Protoflight Medium-To-High-Energy Electron Detector for Integration into a Small On-Board Diagnostic Sensors Package |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T00%3A41%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Design,%20Develop,%20Fabricate,%20Test%20and%20Deliver%20a%20Protoflight%20Medium-To-High-Energy%20Electron%20Detector%20for%20Integration%20into%20a%20Small%20On-Board%20Diagnostic%20Sensors%20Package&rft.au=Belue,%20Jeffrey%20E&rft.aucorp=PANAMETRICS%20INC%20WALTHAM%20MA&rft.date=2003-04-18&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA416913%3C/dtic_1RU%3E%3Cgrp_id%3Ecdi_FETCH-dtic_stinet_ADA4169133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |