Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings

Background To improve the long-term performance of hip prostheses, alternative bearings with metal-on-metal (MoM) and ceramic-on-ceramic (CoC) couples have been introduced. Although currently the results from the use of these bearings are in the midterm stage, there have been few comparative studies...

Full description

Saved in:
Bibliographic Details
Published in:Journal of bone and joint surgery. American volume 2012, Vol.94 (19), p.1756-1763
Main Authors: Milošev, Ingrid, PhD, Kovač, Simon, MD, Trebše, Rihard, MD, Levašič, Vesna, MD, Pišot, Venčeslav, MD
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1763
container_issue 19
container_start_page 1756
container_title Journal of bone and joint surgery. American volume
container_volume 94
creator Milošev, Ingrid, PhD
Kovač, Simon, MD
Trebše, Rihard, MD
Levašič, Vesna, MD
Pišot, Venčeslav, MD
description Background To improve the long-term performance of hip prostheses, alternative bearings with metal-on-metal (MoM) and ceramic-on-ceramic (CoC) couples have been introduced. Although currently the results from the use of these bearings are in the midterm stage, there have been few comparative studies of these different bearings. Methods From 2000 to 2002, 487 total hip replacements were performed with use of a BICON-PLUS acetabular cup and an SL-PLUS femoral stem (Plus Orthopedics, Rotkreuz, Switzerland, now Smith & Nephew Orthopaedics). The patients were divided into three groups according to the type of bearing that was used: an MoM group (sixty-nine prostheses), a metal-on-polyethylene (MoP) group (200 prostheses), and a CoC group (218 prostheses). Patient demographic data and data with regard to revision operations were evaluated from the hospital computer database. The mean follow-up period was 8.5 years (range, 6.9 to 10.5 years). Patient activity was assessed with use of the University of California at Los Angeles activity scale. Results The mean patient age was sixty years at the time of the index arthroplasty in the MoM and CoC groups, and seventy-one years in the MoP group. Based on a scale of ten, the mean postoperative activity level was six in the CoC group, five in the MoM group, and four in the MoP group. Survival at ten years with regard to revision for any reason was 0.984, 0.956, and 0.879 for the MoP, CoC, and MoM groups, respectively. When revision for any reason was considered as the end point, survival of the MoM bearings was significantly worse than that of the MoP bearings (p = 0.005). Survival at ten years with regard to revision for aseptic loosening was 0.995, 0.990, and 0.894 for the MoP, CoC, and MoM groups, respectively. When revision for aseptic loosening was considered as the end point, survival of the MoM group was significantly worse than that of either the MoP group (p = 0.001) or the CoC group (p = 0.003). Conclusions When comparing two groups of patients of similar mean age and mean activity level undergoing total hip arthroplasty with the use of alternative bearings, CoC bearings had better survival than did MoM bearings at the ten-year follow-up; the difference was significant when revision for aseptic loosening was defined as a failure. However, neither the CoC nor the MoM alternative bearings provided improved midterm results when compared with the results of the conventional MoP bearings. For older, less active pati
doi_str_mv 10.1016/S0021-9355(12)70356-9
format article
fullrecord <record><control><sourceid>elsevier</sourceid><recordid>TN_cdi_elsevier_clinicalkeyesjournals_1_s2_0_S0021935512703569</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0021935512703569</els_id><sourcerecordid>1_s2_0_S0021935512703569</sourcerecordid><originalsourceid>FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S00219355127035693</originalsourceid><addsrcrecordid>eNqlj81Kw0AUhWehYP15BGGWCh29kzQt2bgwKN0IhdaFq2EIt2bqdG6ZO43kGXxpk1B8AVfn3HPgHj4hbjU8aNDzxzVAplWZF8Wdzu4XkBdzVZ6JyV98IS6ZdwAwm8FiIn4q2h9sdExB0lZuMKgPtFGuj7F1LUVu3GEolr2sInFqkJHlt0uNfGccqopCiyE5CtbLFfkOU9N5DDiVb5isVxTUaKaSoqww2r2rh_Bk5XM_6MInX4vzrfWMNye9Ek-vL5tqqbA_WofR1N4FV1v_hR3yjo6xn2SjDWcGzIg-IOps5C7zfz_4Ba5ha2g</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings</title><source>HEAL-Link subscriptions: Lippincott Williams &amp; Wilkins</source><creator>Milošev, Ingrid, PhD ; Kovač, Simon, MD ; Trebše, Rihard, MD ; Levašič, Vesna, MD ; Pišot, Venčeslav, MD</creator><creatorcontrib>Milošev, Ingrid, PhD ; Kovač, Simon, MD ; Trebše, Rihard, MD ; Levašič, Vesna, MD ; Pišot, Venčeslav, MD</creatorcontrib><description>Background To improve the long-term performance of hip prostheses, alternative bearings with metal-on-metal (MoM) and ceramic-on-ceramic (CoC) couples have been introduced. Although currently the results from the use of these bearings are in the midterm stage, there have been few comparative studies of these different bearings. Methods From 2000 to 2002, 487 total hip replacements were performed with use of a BICON-PLUS acetabular cup and an SL-PLUS femoral stem (Plus Orthopedics, Rotkreuz, Switzerland, now Smith &amp; Nephew Orthopaedics). The patients were divided into three groups according to the type of bearing that was used: an MoM group (sixty-nine prostheses), a metal-on-polyethylene (MoP) group (200 prostheses), and a CoC group (218 prostheses). Patient demographic data and data with regard to revision operations were evaluated from the hospital computer database. The mean follow-up period was 8.5 years (range, 6.9 to 10.5 years). Patient activity was assessed with use of the University of California at Los Angeles activity scale. Results The mean patient age was sixty years at the time of the index arthroplasty in the MoM and CoC groups, and seventy-one years in the MoP group. Based on a scale of ten, the mean postoperative activity level was six in the CoC group, five in the MoM group, and four in the MoP group. Survival at ten years with regard to revision for any reason was 0.984, 0.956, and 0.879 for the MoP, CoC, and MoM groups, respectively. When revision for any reason was considered as the end point, survival of the MoM bearings was significantly worse than that of the MoP bearings (p = 0.005). Survival at ten years with regard to revision for aseptic loosening was 0.995, 0.990, and 0.894 for the MoP, CoC, and MoM groups, respectively. When revision for aseptic loosening was considered as the end point, survival of the MoM group was significantly worse than that of either the MoP group (p = 0.001) or the CoC group (p = 0.003). Conclusions When comparing two groups of patients of similar mean age and mean activity level undergoing total hip arthroplasty with the use of alternative bearings, CoC bearings had better survival than did MoM bearings at the ten-year follow-up; the difference was significant when revision for aseptic loosening was defined as a failure. However, neither the CoC nor the MoM alternative bearings provided improved midterm results when compared with the results of the conventional MoP bearings. For older, less active patients, traditional metal-on-polyethylene bearings are the appropriate choice. Level of Evidence Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.</description><identifier>ISSN: 0021-9355</identifier><identifier>DOI: 10.1016/S0021-9355(12)70356-9</identifier><language>eng</language><subject>Orthopedics</subject><ispartof>Journal of bone and joint surgery. American volume, 2012, Vol.94 (19), p.1756-1763</ispartof><rights>The Journal of Bone and Joint Surgery, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4009,27902,27903,27904</link.rule.ids></links><search><creatorcontrib>Milošev, Ingrid, PhD</creatorcontrib><creatorcontrib>Kovač, Simon, MD</creatorcontrib><creatorcontrib>Trebše, Rihard, MD</creatorcontrib><creatorcontrib>Levašič, Vesna, MD</creatorcontrib><creatorcontrib>Pišot, Venčeslav, MD</creatorcontrib><title>Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings</title><title>Journal of bone and joint surgery. American volume</title><description>Background To improve the long-term performance of hip prostheses, alternative bearings with metal-on-metal (MoM) and ceramic-on-ceramic (CoC) couples have been introduced. Although currently the results from the use of these bearings are in the midterm stage, there have been few comparative studies of these different bearings. Methods From 2000 to 2002, 487 total hip replacements were performed with use of a BICON-PLUS acetabular cup and an SL-PLUS femoral stem (Plus Orthopedics, Rotkreuz, Switzerland, now Smith &amp; Nephew Orthopaedics). The patients were divided into three groups according to the type of bearing that was used: an MoM group (sixty-nine prostheses), a metal-on-polyethylene (MoP) group (200 prostheses), and a CoC group (218 prostheses). Patient demographic data and data with regard to revision operations were evaluated from the hospital computer database. The mean follow-up period was 8.5 years (range, 6.9 to 10.5 years). Patient activity was assessed with use of the University of California at Los Angeles activity scale. Results The mean patient age was sixty years at the time of the index arthroplasty in the MoM and CoC groups, and seventy-one years in the MoP group. Based on a scale of ten, the mean postoperative activity level was six in the CoC group, five in the MoM group, and four in the MoP group. Survival at ten years with regard to revision for any reason was 0.984, 0.956, and 0.879 for the MoP, CoC, and MoM groups, respectively. When revision for any reason was considered as the end point, survival of the MoM bearings was significantly worse than that of the MoP bearings (p = 0.005). Survival at ten years with regard to revision for aseptic loosening was 0.995, 0.990, and 0.894 for the MoP, CoC, and MoM groups, respectively. When revision for aseptic loosening was considered as the end point, survival of the MoM group was significantly worse than that of either the MoP group (p = 0.001) or the CoC group (p = 0.003). Conclusions When comparing two groups of patients of similar mean age and mean activity level undergoing total hip arthroplasty with the use of alternative bearings, CoC bearings had better survival than did MoM bearings at the ten-year follow-up; the difference was significant when revision for aseptic loosening was defined as a failure. However, neither the CoC nor the MoM alternative bearings provided improved midterm results when compared with the results of the conventional MoP bearings. For older, less active patients, traditional metal-on-polyethylene bearings are the appropriate choice. Level of Evidence Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.</description><subject>Orthopedics</subject><issn>0021-9355</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqlj81Kw0AUhWehYP15BGGWCh29kzQt2bgwKN0IhdaFq2EIt2bqdG6ZO43kGXxpk1B8AVfn3HPgHj4hbjU8aNDzxzVAplWZF8Wdzu4XkBdzVZ6JyV98IS6ZdwAwm8FiIn4q2h9sdExB0lZuMKgPtFGuj7F1LUVu3GEolr2sInFqkJHlt0uNfGccqopCiyE5CtbLFfkOU9N5DDiVb5isVxTUaKaSoqww2r2rh_Bk5XM_6MInX4vzrfWMNye9Ek-vL5tqqbA_WofR1N4FV1v_hR3yjo6xn2SjDWcGzIg-IOps5C7zfz_4Ba5ha2g</recordid><startdate>2012</startdate><enddate>2012</enddate><creator>Milošev, Ingrid, PhD</creator><creator>Kovač, Simon, MD</creator><creator>Trebše, Rihard, MD</creator><creator>Levašič, Vesna, MD</creator><creator>Pišot, Venčeslav, MD</creator><scope/></search><sort><creationdate>2012</creationdate><title>Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings</title><author>Milošev, Ingrid, PhD ; Kovač, Simon, MD ; Trebše, Rihard, MD ; Levašič, Vesna, MD ; Pišot, Venčeslav, MD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S00219355127035693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Milošev, Ingrid, PhD</creatorcontrib><creatorcontrib>Kovač, Simon, MD</creatorcontrib><creatorcontrib>Trebše, Rihard, MD</creatorcontrib><creatorcontrib>Levašič, Vesna, MD</creatorcontrib><creatorcontrib>Pišot, Venčeslav, MD</creatorcontrib><jtitle>Journal of bone and joint surgery. American volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Milošev, Ingrid, PhD</au><au>Kovač, Simon, MD</au><au>Trebše, Rihard, MD</au><au>Levašič, Vesna, MD</au><au>Pišot, Venčeslav, MD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings</atitle><jtitle>Journal of bone and joint surgery. American volume</jtitle><date>2012</date><risdate>2012</risdate><volume>94</volume><issue>19</issue><spage>1756</spage><epage>1763</epage><pages>1756-1763</pages><issn>0021-9355</issn><abstract>Background To improve the long-term performance of hip prostheses, alternative bearings with metal-on-metal (MoM) and ceramic-on-ceramic (CoC) couples have been introduced. Although currently the results from the use of these bearings are in the midterm stage, there have been few comparative studies of these different bearings. Methods From 2000 to 2002, 487 total hip replacements were performed with use of a BICON-PLUS acetabular cup and an SL-PLUS femoral stem (Plus Orthopedics, Rotkreuz, Switzerland, now Smith &amp; Nephew Orthopaedics). The patients were divided into three groups according to the type of bearing that was used: an MoM group (sixty-nine prostheses), a metal-on-polyethylene (MoP) group (200 prostheses), and a CoC group (218 prostheses). Patient demographic data and data with regard to revision operations were evaluated from the hospital computer database. The mean follow-up period was 8.5 years (range, 6.9 to 10.5 years). Patient activity was assessed with use of the University of California at Los Angeles activity scale. Results The mean patient age was sixty years at the time of the index arthroplasty in the MoM and CoC groups, and seventy-one years in the MoP group. Based on a scale of ten, the mean postoperative activity level was six in the CoC group, five in the MoM group, and four in the MoP group. Survival at ten years with regard to revision for any reason was 0.984, 0.956, and 0.879 for the MoP, CoC, and MoM groups, respectively. When revision for any reason was considered as the end point, survival of the MoM bearings was significantly worse than that of the MoP bearings (p = 0.005). Survival at ten years with regard to revision for aseptic loosening was 0.995, 0.990, and 0.894 for the MoP, CoC, and MoM groups, respectively. When revision for aseptic loosening was considered as the end point, survival of the MoM group was significantly worse than that of either the MoP group (p = 0.001) or the CoC group (p = 0.003). Conclusions When comparing two groups of patients of similar mean age and mean activity level undergoing total hip arthroplasty with the use of alternative bearings, CoC bearings had better survival than did MoM bearings at the ten-year follow-up; the difference was significant when revision for aseptic loosening was defined as a failure. However, neither the CoC nor the MoM alternative bearings provided improved midterm results when compared with the results of the conventional MoP bearings. For older, less active patients, traditional metal-on-polyethylene bearings are the appropriate choice. Level of Evidence Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.</abstract><doi>10.1016/S0021-9355(12)70356-9</doi></addata></record>
fulltext fulltext
identifier ISSN: 0021-9355
ispartof Journal of bone and joint surgery. American volume, 2012, Vol.94 (19), p.1756-1763
issn 0021-9355
language eng
recordid cdi_elsevier_clinicalkeyesjournals_1_s2_0_S0021935512703569
source HEAL-Link subscriptions: Lippincott Williams & Wilkins
subjects Orthopedics
title Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T14%3A42%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Ten-Year%20Survivorship%20of%20Hip%20Prostheses%20with%20Use%20of%20Conventional%20Polyethylene,%20Metal-on-Metal,%20or%20Ceramic-on-Ceramic%20Bearings&rft.jtitle=Journal%20of%20bone%20and%20joint%20surgery.%20American%20volume&rft.au=Milo%C5%A1ev,%20Ingrid,%20PhD&rft.date=2012&rft.volume=94&rft.issue=19&rft.spage=1756&rft.epage=1763&rft.pages=1756-1763&rft.issn=0021-9355&rft_id=info:doi/10.1016/S0021-9355(12)70356-9&rft_dat=%3Celsevier%3E1_s2_0_S0021935512703569%3C/elsevier%3E%3Cgrp_id%3Ecdi_FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S00219355127035693%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true