International Comparative Evaluation of Knee Replacement with Fixed or Mobile-Bearing Posterior-Stabilized Prostheses
Background Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In thi...
Saved in:
Published in: | Journal of bone and joint surgery. American volume 2014, Vol.96, p.59-64 |
---|---|
Main Authors: | , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 64 |
container_issue | |
container_start_page | 59 |
container_title | Journal of bone and joint surgery. American volume |
container_volume | 96 |
creator | Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA Sedrakyan, Art, MD, PhD Banerjee, Samprit, PhD Isaacs, Abby J., MS Baste, Valborg, PhD Gioe, Terence J., MD Namba, Robert, MD Paxton, Elizabeth, MA Cruz, Olga Martínez Stea, Susanna, BSc Robertsson, Otto, Med Dr |
description | Background Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Methods Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. Results This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Conclusions Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first |
doi_str_mv | 10.1016/S0021-9355(14)74501-1 |
format | article |
fullrecord | <record><control><sourceid>elsevier</sourceid><recordid>TN_cdi_elsevier_clinicalkeyesjournals_1_s2_0_S0021935514745011</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0021935514745011</els_id><sourcerecordid>1_s2_0_S0021935514745011</sourcerecordid><originalsourceid>FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S00219355147450113</originalsourceid><addsrcrecordid>eNqlj8tKQzEQhrNQsF4eQZilLo7OtDkWNy4sLRYRinUf4nFqp6ZJSXKOl6c3HsQXcDX8F37mU-qU8IKQri6XiEOqrkd1fUb6fKxrpIr21ODPPlCHKW0QUWscD1Q795mjt1mCtw4mYbuzsaiOYdpZ1_YBhBXce2Z45J2zDW_ZZ3iXvIaZfPALhAgP4VkcV7dso_hXWIRUZiXEapltSeSr1BaxuGtOnI7V_sq6xCe_90jdzKZPk7uKi-iEo2mceGmse-NPTpvQlhddMmTS0KDpIX9gSPeENPr3wDfdGmRx</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>International Comparative Evaluation of Knee Replacement with Fixed or Mobile-Bearing Posterior-Stabilized Prostheses</title><source>HEAL-Link subscriptions: Lippincott Williams & Wilkins</source><creator>Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA ; Sedrakyan, Art, MD, PhD ; Banerjee, Samprit, PhD ; Isaacs, Abby J., MS ; Baste, Valborg, PhD ; Gioe, Terence J., MD ; Namba, Robert, MD ; Paxton, Elizabeth, MA ; Cruz, Olga Martínez ; Stea, Susanna, BSc ; Robertsson, Otto, Med Dr</creator><creatorcontrib>Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA ; Sedrakyan, Art, MD, PhD ; Banerjee, Samprit, PhD ; Isaacs, Abby J., MS ; Baste, Valborg, PhD ; Gioe, Terence J., MD ; Namba, Robert, MD ; Paxton, Elizabeth, MA ; Cruz, Olga Martínez ; Stea, Susanna, BSc ; Robertsson, Otto, Med Dr</creatorcontrib><description>Background Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Methods Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. Results This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Conclusions Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first year.</description><identifier>ISSN: 0021-9355</identifier><identifier>DOI: 10.1016/S0021-9355(14)74501-1</identifier><language>eng</language><subject>Orthopedics</subject><ispartof>Journal of bone and joint surgery. American volume, 2014, Vol.96, p.59-64</ispartof><rights>The Journal of Bone and Joint Surgery, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA</creatorcontrib><creatorcontrib>Sedrakyan, Art, MD, PhD</creatorcontrib><creatorcontrib>Banerjee, Samprit, PhD</creatorcontrib><creatorcontrib>Isaacs, Abby J., MS</creatorcontrib><creatorcontrib>Baste, Valborg, PhD</creatorcontrib><creatorcontrib>Gioe, Terence J., MD</creatorcontrib><creatorcontrib>Namba, Robert, MD</creatorcontrib><creatorcontrib>Paxton, Elizabeth, MA</creatorcontrib><creatorcontrib>Cruz, Olga Martínez</creatorcontrib><creatorcontrib>Stea, Susanna, BSc</creatorcontrib><creatorcontrib>Robertsson, Otto, Med Dr</creatorcontrib><title>International Comparative Evaluation of Knee Replacement with Fixed or Mobile-Bearing Posterior-Stabilized Prostheses</title><title>Journal of bone and joint surgery. American volume</title><description>Background Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Methods Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. Results This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Conclusions Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first year.</description><subject>Orthopedics</subject><issn>0021-9355</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqlj8tKQzEQhrNQsF4eQZilLo7OtDkWNy4sLRYRinUf4nFqp6ZJSXKOl6c3HsQXcDX8F37mU-qU8IKQri6XiEOqrkd1fUb6fKxrpIr21ODPPlCHKW0QUWscD1Q795mjt1mCtw4mYbuzsaiOYdpZ1_YBhBXce2Z45J2zDW_ZZ3iXvIaZfPALhAgP4VkcV7dso_hXWIRUZiXEapltSeSr1BaxuGtOnI7V_sq6xCe_90jdzKZPk7uKi-iEo2mceGmse-NPTpvQlhddMmTS0KDpIX9gSPeENPr3wDfdGmRx</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA</creator><creator>Sedrakyan, Art, MD, PhD</creator><creator>Banerjee, Samprit, PhD</creator><creator>Isaacs, Abby J., MS</creator><creator>Baste, Valborg, PhD</creator><creator>Gioe, Terence J., MD</creator><creator>Namba, Robert, MD</creator><creator>Paxton, Elizabeth, MA</creator><creator>Cruz, Olga Martínez</creator><creator>Stea, Susanna, BSc</creator><creator>Robertsson, Otto, Med Dr</creator><scope/></search><sort><creationdate>2014</creationdate><title>International Comparative Evaluation of Knee Replacement with Fixed or Mobile-Bearing Posterior-Stabilized Prostheses</title><author>Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA ; Sedrakyan, Art, MD, PhD ; Banerjee, Samprit, PhD ; Isaacs, Abby J., MS ; Baste, Valborg, PhD ; Gioe, Terence J., MD ; Namba, Robert, MD ; Paxton, Elizabeth, MA ; Cruz, Olga Martínez ; Stea, Susanna, BSc ; Robertsson, Otto, Med Dr</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S00219355147450113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA</creatorcontrib><creatorcontrib>Sedrakyan, Art, MD, PhD</creatorcontrib><creatorcontrib>Banerjee, Samprit, PhD</creatorcontrib><creatorcontrib>Isaacs, Abby J., MS</creatorcontrib><creatorcontrib>Baste, Valborg, PhD</creatorcontrib><creatorcontrib>Gioe, Terence J., MD</creatorcontrib><creatorcontrib>Namba, Robert, MD</creatorcontrib><creatorcontrib>Paxton, Elizabeth, MA</creatorcontrib><creatorcontrib>Cruz, Olga Martínez</creatorcontrib><creatorcontrib>Stea, Susanna, BSc</creatorcontrib><creatorcontrib>Robertsson, Otto, Med Dr</creatorcontrib><jtitle>Journal of bone and joint surgery. American volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Graves, Stephen, MBBS, DPhil, FRACS, FAOrthA</au><au>Sedrakyan, Art, MD, PhD</au><au>Banerjee, Samprit, PhD</au><au>Isaacs, Abby J., MS</au><au>Baste, Valborg, PhD</au><au>Gioe, Terence J., MD</au><au>Namba, Robert, MD</au><au>Paxton, Elizabeth, MA</au><au>Cruz, Olga Martínez</au><au>Stea, Susanna, BSc</au><au>Robertsson, Otto, Med Dr</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>International Comparative Evaluation of Knee Replacement with Fixed or Mobile-Bearing Posterior-Stabilized Prostheses</atitle><jtitle>Journal of bone and joint surgery. American volume</jtitle><date>2014</date><risdate>2014</risdate><volume>96</volume><spage>59</spage><epage>64</epage><pages>59-64</pages><issn>0021-9355</issn><abstract>Background Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Methods Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. Results This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Conclusions Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first year.</abstract><doi>10.1016/S0021-9355(14)74501-1</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9355 |
ispartof | Journal of bone and joint surgery. American volume, 2014, Vol.96, p.59-64 |
issn | 0021-9355 |
language | eng |
recordid | cdi_elsevier_clinicalkeyesjournals_1_s2_0_S0021935514745011 |
source | HEAL-Link subscriptions: Lippincott Williams & Wilkins |
subjects | Orthopedics |
title | International Comparative Evaluation of Knee Replacement with Fixed or Mobile-Bearing Posterior-Stabilized Prostheses |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T17%3A47%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=International%20Comparative%20Evaluation%20of%20Knee%20Replacement%20with%20Fixed%20or%20Mobile-Bearing%20Posterior-Stabilized%20Prostheses&rft.jtitle=Journal%20of%20bone%20and%20joint%20surgery.%20American%20volume&rft.au=Graves,%20Stephen,%20MBBS,%20DPhil,%20FRACS,%20FAOrthA&rft.date=2014&rft.volume=96&rft.spage=59&rft.epage=64&rft.pages=59-64&rft.issn=0021-9355&rft_id=info:doi/10.1016/S0021-9355(14)74501-1&rft_dat=%3Celsevier%3E1_s2_0_S0021935514745011%3C/elsevier%3E%3Cgrp_id%3Ecdi_FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S00219355147450113%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |