Loading…
The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients
Inadequacy of dialysis is one of the determinants of morbidity and mortality in patients undergoing dialysis. The aim of this study was to assess the effect of increasing blood flow rate during hemodialysis (HD) on the adequacy of dialysis. In this study, 42 patients on maintenance HD were assesse...
Saved in:
Published in: | Saudi journal of kidney diseases and transplantation 2009-07, Vol.20 (4), p.639-642 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 642 |
container_issue | 4 |
container_start_page | 639 |
container_title | Saudi journal of kidney diseases and transplantation |
container_volume | 20 |
creator | Amini, R. Borzou, S. R. Goodarzi, Muhammad Taqi Zandiha, M. Gholyaf, M. Torkaman, B. |
description | Inadequacy of dialysis is one of the determinants of morbidity and mortality in patients undergoing dialysis. The aim of this study was to assess the effect of increasing blood flow rate during hemodialysis (HD) on the adequacy of dialysis. In this study, 42 patients on maintenance HD were assessed. Body weight and blood urea nitrogen (BUN) levels before and after HD sessions were recorded on all the study patients. Volume of ultrafiltration, the duration of dialysis, percentage of filter clearance and flow rate of the dialysate were collected and documented in a checklist. Both Kt / V and urea reduction ratio (URR) were determined at two different blood pump speeds, i.e. 200 and 250 mL / min. During HD, hemodynamic status and vital signs of patients were monitored and controlled. After collecting the necessary data, efficiency of dialysis was calculated using the standard formula. Descriptive and analytical statistics was carried out to analyze the data. Using blood flow rate of 200 mL / min, 16.7% of patients had Kt / V higher than 1.3 and URR higher than 65. On the other hand, with flow rate of 250 mL / min, 26.2% of patients had Kt / V higher than 1.3 and 35.7% of subjects had URR higher than 65. Paired t-test with 95% confidence showed a significant difference in dialysis efficiency between two groups. Our data further confirm that increasing the blood flow rate by 25% is effective in increasing dialysis adequacy in HD patients. |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_emarefa_primary_37280</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A241494596</galeid><doaj_id>oai_doaj_org_article_7bd9df7ee418408a94e1be91a59bca4a</doaj_id><sourcerecordid>A241494596</sourcerecordid><originalsourceid>FETCH-LOGICAL-d366t-ae6e550e9f3688835fc38d2f4dc3e1305b285bf1acd086f6138e53a1c2c94dc43</originalsourceid><addsrcrecordid>eNpVkU1r3DAQhk1oaDZJ_0EoOvXmIlkflo4htGkgkEvaqxlLo10F2dpYMmX_fUU23VJ0GHj16GFGc9ZsOt7RlmuuPzQbxplpOyG6i-Yy5xdKpTRKfWwumJG6l7TfNL-ed0jQe7SFJE_CbBeEHOYtGWNKjviYfpMFCpI0ExcgHnLIBBy-rmAPlSc7nNLpYg8l4FzydXPuIWb89F6vmp_fvz3f_Wgfn-4f7m4fW8eVKi2gQikpGs-V1ppLb7l2nRfOcmScyrHTcvQMrKNaecW4RsmB2c6aygh-1TwcvS7By7BfwgTLYUgQhrcgLdsBlhJsxKEfnXG-RxRMC6rBCGQjGgbSjBYEVNeXo2u_pNcVcxmmkC3GCDOmNQ-qF72gPa3g1yO4heoNs09lAVuPwynYNKMPNb_tBBNG1B__Z357sEOIZZdTXEtIc_4f_PzewjpO6E4D_d1XBW6OANYcPZwI3nea8j8vkZuF</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67474070</pqid></control><display><type>article</type><title>The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients</title><source>Medknow Open Access Medical Journals(OpenAccess)</source><creator>Amini, R. ; Borzou, S. R. ; Goodarzi, Muhammad Taqi ; Zandiha, M. ; Gholyaf, M. ; Torkaman, B.</creator><creatorcontrib>Amini, R. ; Borzou, S. R. ; Goodarzi, Muhammad Taqi ; Zandiha, M. ; Gholyaf, M. ; Torkaman, B.</creatorcontrib><description>Inadequacy of dialysis is one of the determinants of morbidity and mortality in patients undergoing dialysis. The aim of this study was to assess the effect of increasing blood flow rate during hemodialysis (HD) on the adequacy of dialysis. In this study, 42 patients on maintenance HD were assessed. Body weight and blood urea nitrogen (BUN) levels before and after HD sessions were recorded on all the study patients. Volume of ultrafiltration, the duration of dialysis, percentage of filter clearance and flow rate of the dialysate were collected and documented in a checklist. Both Kt / V and urea reduction ratio (URR) were determined at two different blood pump speeds, i.e. 200 and 250 mL / min. During HD, hemodynamic status and vital signs of patients were monitored and controlled. After collecting the necessary data, efficiency of dialysis was calculated using the standard formula. Descriptive and analytical statistics was carried out to analyze the data. Using blood flow rate of 200 mL / min, 16.7% of patients had Kt / V higher than 1.3 and URR higher than 65. On the other hand, with flow rate of 250 mL / min, 26.2% of patients had Kt / V higher than 1.3 and 35.7% of subjects had URR higher than 65. Paired t-test with 95% confidence showed a significant difference in dialysis efficiency between two groups. Our data further confirm that increasing the blood flow rate by 25% is effective in increasing dialysis adequacy in HD patients.</description><identifier>ISSN: 1319-2442</identifier><identifier>EISSN: 2320-3838</identifier><identifier>PMID: 19587507</identifier><language>eng</language><publisher>Riyadh, Saudi Arabia: Saudi Center for Organ Transplantation</publisher><subject>Adequacy ; Adult ; Blood flow ; Blood flow rates ; Blood Flow Velocity - physiology ; Dialysis ; Female ; Health aspects ; Hemodialysis ; Humans ; Kidney Failure, Chronic - mortality ; Kidney Failure, Chronic - therapy ; Male ; Measurement ; Medical research ; Medicine, Experimental ; Metabolic Clearance Rate - physiology ; Middle Aged ; Renal Dialysis - methods ; Treatment Outcome ; Urea ; الأسموزية ; الدم ; المرضى ; جريان الدم ; غسيل الكلى</subject><ispartof>Saudi journal of kidney diseases and transplantation, 2009-07, Vol.20 (4), p.639-642</ispartof><rights>COPYRIGHT 2009 Medknow Publications and Media Pvt. Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19587507$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Amini, R.</creatorcontrib><creatorcontrib>Borzou, S. R.</creatorcontrib><creatorcontrib>Goodarzi, Muhammad Taqi</creatorcontrib><creatorcontrib>Zandiha, M.</creatorcontrib><creatorcontrib>Gholyaf, M.</creatorcontrib><creatorcontrib>Torkaman, B.</creatorcontrib><title>The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients</title><title>Saudi journal of kidney diseases and transplantation</title><addtitle>Saudi J Kidney Dis Transpl</addtitle><description>Inadequacy of dialysis is one of the determinants of morbidity and mortality in patients undergoing dialysis. The aim of this study was to assess the effect of increasing blood flow rate during hemodialysis (HD) on the adequacy of dialysis. In this study, 42 patients on maintenance HD were assessed. Body weight and blood urea nitrogen (BUN) levels before and after HD sessions were recorded on all the study patients. Volume of ultrafiltration, the duration of dialysis, percentage of filter clearance and flow rate of the dialysate were collected and documented in a checklist. Both Kt / V and urea reduction ratio (URR) were determined at two different blood pump speeds, i.e. 200 and 250 mL / min. During HD, hemodynamic status and vital signs of patients were monitored and controlled. After collecting the necessary data, efficiency of dialysis was calculated using the standard formula. Descriptive and analytical statistics was carried out to analyze the data. Using blood flow rate of 200 mL / min, 16.7% of patients had Kt / V higher than 1.3 and URR higher than 65. On the other hand, with flow rate of 250 mL / min, 26.2% of patients had Kt / V higher than 1.3 and 35.7% of subjects had URR higher than 65. Paired t-test with 95% confidence showed a significant difference in dialysis efficiency between two groups. Our data further confirm that increasing the blood flow rate by 25% is effective in increasing dialysis adequacy in HD patients.</description><subject>Adequacy</subject><subject>Adult</subject><subject>Blood flow</subject><subject>Blood flow rates</subject><subject>Blood Flow Velocity - physiology</subject><subject>Dialysis</subject><subject>Female</subject><subject>Health aspects</subject><subject>Hemodialysis</subject><subject>Humans</subject><subject>Kidney Failure, Chronic - mortality</subject><subject>Kidney Failure, Chronic - therapy</subject><subject>Male</subject><subject>Measurement</subject><subject>Medical research</subject><subject>Medicine, Experimental</subject><subject>Metabolic Clearance Rate - physiology</subject><subject>Middle Aged</subject><subject>Renal Dialysis - methods</subject><subject>Treatment Outcome</subject><subject>Urea</subject><subject>الأسموزية</subject><subject>الدم</subject><subject>المرضى</subject><subject>جريان الدم</subject><subject>غسيل الكلى</subject><issn>1319-2442</issn><issn>2320-3838</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVkU1r3DAQhk1oaDZJ_0EoOvXmIlkflo4htGkgkEvaqxlLo10F2dpYMmX_fUU23VJ0GHj16GFGc9ZsOt7RlmuuPzQbxplpOyG6i-Yy5xdKpTRKfWwumJG6l7TfNL-ed0jQe7SFJE_CbBeEHOYtGWNKjviYfpMFCpI0ExcgHnLIBBy-rmAPlSc7nNLpYg8l4FzydXPuIWb89F6vmp_fvz3f_Wgfn-4f7m4fW8eVKi2gQikpGs-V1ppLb7l2nRfOcmScyrHTcvQMrKNaecW4RsmB2c6aygh-1TwcvS7By7BfwgTLYUgQhrcgLdsBlhJsxKEfnXG-RxRMC6rBCGQjGgbSjBYEVNeXo2u_pNcVcxmmkC3GCDOmNQ-qF72gPa3g1yO4heoNs09lAVuPwynYNKMPNb_tBBNG1B__Z357sEOIZZdTXEtIc_4f_PzewjpO6E4D_d1XBW6OANYcPZwI3nea8j8vkZuF</recordid><startdate>20090701</startdate><enddate>20090701</enddate><creator>Amini, R.</creator><creator>Borzou, S. R.</creator><creator>Goodarzi, Muhammad Taqi</creator><creator>Zandiha, M.</creator><creator>Gholyaf, M.</creator><creator>Torkaman, B.</creator><general>Saudi Center for Organ Transplantation</general><general>Medknow Publications and Media Pvt. Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>ADJCN</scope><scope>AHFXO</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope><scope>DOA</scope></search><sort><creationdate>20090701</creationdate><title>The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients</title><author>Amini, R. ; Borzou, S. R. ; Goodarzi, Muhammad Taqi ; Zandiha, M. ; Gholyaf, M. ; Torkaman, B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d366t-ae6e550e9f3688835fc38d2f4dc3e1305b285bf1acd086f6138e53a1c2c94dc43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Adequacy</topic><topic>Adult</topic><topic>Blood flow</topic><topic>Blood flow rates</topic><topic>Blood Flow Velocity - physiology</topic><topic>Dialysis</topic><topic>Female</topic><topic>Health aspects</topic><topic>Hemodialysis</topic><topic>Humans</topic><topic>Kidney Failure, Chronic - mortality</topic><topic>Kidney Failure, Chronic - therapy</topic><topic>Male</topic><topic>Measurement</topic><topic>Medical research</topic><topic>Medicine, Experimental</topic><topic>Metabolic Clearance Rate - physiology</topic><topic>Middle Aged</topic><topic>Renal Dialysis - methods</topic><topic>Treatment Outcome</topic><topic>Urea</topic><topic>الأسموزية</topic><topic>الدم</topic><topic>المرضى</topic><topic>جريان الدم</topic><topic>غسيل الكلى</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Amini, R.</creatorcontrib><creatorcontrib>Borzou, S. R.</creatorcontrib><creatorcontrib>Goodarzi, Muhammad Taqi</creatorcontrib><creatorcontrib>Zandiha, M.</creatorcontrib><creatorcontrib>Gholyaf, M.</creatorcontrib><creatorcontrib>Torkaman, B.</creatorcontrib><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Saudi journal of kidney diseases and transplantation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Amini, R.</au><au>Borzou, S. R.</au><au>Goodarzi, Muhammad Taqi</au><au>Zandiha, M.</au><au>Gholyaf, M.</au><au>Torkaman, B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients</atitle><jtitle>Saudi journal of kidney diseases and transplantation</jtitle><addtitle>Saudi J Kidney Dis Transpl</addtitle><date>2009-07-01</date><risdate>2009</risdate><volume>20</volume><issue>4</issue><spage>639</spage><epage>642</epage><pages>639-642</pages><issn>1319-2442</issn><eissn>2320-3838</eissn><abstract>Inadequacy of dialysis is one of the determinants of morbidity and mortality in patients undergoing dialysis. The aim of this study was to assess the effect of increasing blood flow rate during hemodialysis (HD) on the adequacy of dialysis. In this study, 42 patients on maintenance HD were assessed. Body weight and blood urea nitrogen (BUN) levels before and after HD sessions were recorded on all the study patients. Volume of ultrafiltration, the duration of dialysis, percentage of filter clearance and flow rate of the dialysate were collected and documented in a checklist. Both Kt / V and urea reduction ratio (URR) were determined at two different blood pump speeds, i.e. 200 and 250 mL / min. During HD, hemodynamic status and vital signs of patients were monitored and controlled. After collecting the necessary data, efficiency of dialysis was calculated using the standard formula. Descriptive and analytical statistics was carried out to analyze the data. Using blood flow rate of 200 mL / min, 16.7% of patients had Kt / V higher than 1.3 and URR higher than 65. On the other hand, with flow rate of 250 mL / min, 26.2% of patients had Kt / V higher than 1.3 and 35.7% of subjects had URR higher than 65. Paired t-test with 95% confidence showed a significant difference in dialysis efficiency between two groups. Our data further confirm that increasing the blood flow rate by 25% is effective in increasing dialysis adequacy in HD patients.</abstract><cop>Riyadh, Saudi Arabia</cop><pub>Saudi Center for Organ Transplantation</pub><pmid>19587507</pmid><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1319-2442 |
ispartof | Saudi journal of kidney diseases and transplantation, 2009-07, Vol.20 (4), p.639-642 |
issn | 1319-2442 2320-3838 |
language | eng |
recordid | cdi_emarefa_primary_37280 |
source | Medknow Open Access Medical Journals(OpenAccess) |
subjects | Adequacy Adult Blood flow Blood flow rates Blood Flow Velocity - physiology Dialysis Female Health aspects Hemodialysis Humans Kidney Failure, Chronic - mortality Kidney Failure, Chronic - therapy Male Measurement Medical research Medicine, Experimental Metabolic Clearance Rate - physiology Middle Aged Renal Dialysis - methods Treatment Outcome Urea الأسموزية الدم المرضى جريان الدم غسيل الكلى |
title | The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T03%3A17%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20of%20increasing%20blood%20flow%20rate%20on%20dialysis%20adequacy%20in%20hemodialysis%20patients&rft.jtitle=Saudi%20journal%20of%20kidney%20diseases%20and%20transplantation&rft.au=Amini,%20R.&rft.date=2009-07-01&rft.volume=20&rft.issue=4&rft.spage=639&rft.epage=642&rft.pages=639-642&rft.issn=1319-2442&rft.eissn=2320-3838&rft_id=info:doi/&rft_dat=%3Cgale_doaj_%3EA241494596%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-d366t-ae6e550e9f3688835fc38d2f4dc3e1305b285bf1acd086f6138e53a1c2c94dc43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67474070&rft_id=info:pmid/19587507&rft_galeid=A241494596&rfr_iscdi=true |