Decontamination of discharged aluminum brass condenser tubes of a BWR: evolving the chemical formulation for copper oxide dissolution
Chemical formulations for copper oxide dissolution have been evaluated primarily for the minimum ionic load resulting in the spent formulation along with other desirable qualities. Peroxydisulfuric acid prepared freshly through ion exchange route has shown almost stoichiometric dissolution of the co...
Saved in:
Published in: | Journal of radioanalytical and nuclear chemistry 2016-01, Vol.307 (1), p.217-223 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Chemical formulations for copper oxide dissolution have been evaluated primarily for the minimum ionic load resulting in the spent formulation along with other desirable qualities. Peroxydisulfuric acid prepared freshly through ion exchange route has shown almost stoichiometric dissolution of the copper oxide as per the acidic oxidative action with efficient kinetics. Stability of the prepared formulation for its application and its effective oxidizing behaviour and aqueous cupric ion stabilizing by its redox product has been established experimentally. |
---|---|
ISSN: | 0236-5731 1588-2780 |
DOI: | 10.1007/s10967-015-4204-4 |