Loading…

Decontamination of discharged aluminum brass condenser tubes of a BWR: evolving the chemical formulation for copper oxide dissolution

Chemical formulations for copper oxide dissolution have been evaluated primarily for the minimum ionic load resulting in the spent formulation along with other desirable qualities. Peroxydisulfuric acid prepared freshly through ion exchange route has shown almost stoichiometric dissolution of the co...

Full description

Saved in:
Bibliographic Details
Published in:Journal of radioanalytical and nuclear chemistry 2016-01, Vol.307 (1), p.217-223
Main Authors: Bairwa, K. K., Tripathi, V. S., Naik, D. B., Tyagi, A. K., Papachan, D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Chemical formulations for copper oxide dissolution have been evaluated primarily for the minimum ionic load resulting in the spent formulation along with other desirable qualities. Peroxydisulfuric acid prepared freshly through ion exchange route has shown almost stoichiometric dissolution of the copper oxide as per the acidic oxidative action with efficient kinetics. Stability of the prepared formulation for its application and its effective oxidizing behaviour and aqueous cupric ion stabilizing by its redox product has been established experimentally.
ISSN:0236-5731
1588-2780
DOI:10.1007/s10967-015-4204-4