Loading…
Revision of nuclear data of .sup.235U and .sup.226Ra for the 186-keV gamma-ray peak for the determination of activity in environmental samples
In this work, the ratio contribution of .sup.226Ra and .sup.235U in [gamma] spectra with the latest update nuclear data will be revised. The results showed that in the total count rate of the 186 keV peak consists of 57.2% of .sup.226Ra (186.2 keV) and 42.8% of .sup.235U (185.7 keV) with the existen...
Saved in:
Published in: | Journal of radioanalytical and nuclear chemistry 2017-11, Vol.314 (2), p.1273 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 2 |
container_start_page | 1273 |
container_title | Journal of radioanalytical and nuclear chemistry |
container_volume | 314 |
creator | Vuong, Le Quang Chuong, Huynh Dinh Nguyen, Vo Hoang Hung, Nguyen Quoc Thanh, Tran Thien Van Tao, Chau |
description | In this work, the ratio contribution of .sup.226Ra and .sup.235U in [gamma] spectra with the latest update nuclear data will be revised. The results showed that in the total count rate of the 186 keV peak consists of 57.2% of .sup.226Ra (186.2 keV) and 42.8% of .sup.235U (185.7 keV) with the existence of equilibrium. These calculations were used for determining mass activity of .sup.238U for the direct and fast measurement using only the 186 keV peak and verifying the .sup.238U-.sup.226Ra secular equilibrium. An equilibrium method was measured secular equilibrium of decay chain .sup.238U (by the product daughter .sup.214Bi-609.3 keV) that was used for this study. The maximum relative deviation was less than 4.0% between both methods proved the direct method was reliable and can be applied to determine the mass activity of .sup.238U in the radioactive equilibrium samples. |
doi_str_mv | 10.1007/s10967-017-5461-1 |
format | article |
fullrecord | <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracacademiconefile_A511784960</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A511784960</galeid><sourcerecordid>A511784960</sourcerecordid><originalsourceid>FETCH-gale_infotracacademiconefile_A5117849603</originalsourceid><addsrcrecordid>eNqVjU1OwzAUhL0AqeXnAOzeBRzsuHGSJUIg1hVli56S59bUP5HtRuolODNFitijWYy-GY2GsQcpKilE-5il6HXLhWx5s9GSyyu2FrXSvGmVXLGbnL-EEH3XqTX73tJss40BooFwGhxhghEL_nKVT1NVq2YHGMaFar1FMDFBORDITvMjfcAevUee8AwT4fGvHqlQ8jZgWQ5wKHa25Qw2AIXZphg8hYIOMvrJUb5j1wZdpvvFb1n1-vL-_Mb36OjTBhNLwuGikbwdYiBjL_lTI2XbbXot1L8HPy1LYEk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Revision of nuclear data of .sup.235U and .sup.226Ra for the 186-keV gamma-ray peak for the determination of activity in environmental samples</title><source>Springer Nature</source><creator>Vuong, Le Quang ; Chuong, Huynh Dinh ; Nguyen, Vo Hoang ; Hung, Nguyen Quoc ; Thanh, Tran Thien ; Van Tao, Chau</creator><creatorcontrib>Vuong, Le Quang ; Chuong, Huynh Dinh ; Nguyen, Vo Hoang ; Hung, Nguyen Quoc ; Thanh, Tran Thien ; Van Tao, Chau</creatorcontrib><description>In this work, the ratio contribution of .sup.226Ra and .sup.235U in [gamma] spectra with the latest update nuclear data will be revised. The results showed that in the total count rate of the 186 keV peak consists of 57.2% of .sup.226Ra (186.2 keV) and 42.8% of .sup.235U (185.7 keV) with the existence of equilibrium. These calculations were used for determining mass activity of .sup.238U for the direct and fast measurement using only the 186 keV peak and verifying the .sup.238U-.sup.226Ra secular equilibrium. An equilibrium method was measured secular equilibrium of decay chain .sup.238U (by the product daughter .sup.214Bi-609.3 keV) that was used for this study. The maximum relative deviation was less than 4.0% between both methods proved the direct method was reliable and can be applied to determine the mass activity of .sup.238U in the radioactive equilibrium samples.</description><identifier>ISSN: 0236-5731</identifier><identifier>DOI: 10.1007/s10967-017-5461-1</identifier><language>eng</language><publisher>Springer</publisher><subject>Gamma rays ; Nuclear energy ; Uranium</subject><ispartof>Journal of radioanalytical and nuclear chemistry, 2017-11, Vol.314 (2), p.1273</ispartof><rights>COPYRIGHT 2017 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Vuong, Le Quang</creatorcontrib><creatorcontrib>Chuong, Huynh Dinh</creatorcontrib><creatorcontrib>Nguyen, Vo Hoang</creatorcontrib><creatorcontrib>Hung, Nguyen Quoc</creatorcontrib><creatorcontrib>Thanh, Tran Thien</creatorcontrib><creatorcontrib>Van Tao, Chau</creatorcontrib><title>Revision of nuclear data of .sup.235U and .sup.226Ra for the 186-keV gamma-ray peak for the determination of activity in environmental samples</title><title>Journal of radioanalytical and nuclear chemistry</title><description>In this work, the ratio contribution of .sup.226Ra and .sup.235U in [gamma] spectra with the latest update nuclear data will be revised. The results showed that in the total count rate of the 186 keV peak consists of 57.2% of .sup.226Ra (186.2 keV) and 42.8% of .sup.235U (185.7 keV) with the existence of equilibrium. These calculations were used for determining mass activity of .sup.238U for the direct and fast measurement using only the 186 keV peak and verifying the .sup.238U-.sup.226Ra secular equilibrium. An equilibrium method was measured secular equilibrium of decay chain .sup.238U (by the product daughter .sup.214Bi-609.3 keV) that was used for this study. The maximum relative deviation was less than 4.0% between both methods proved the direct method was reliable and can be applied to determine the mass activity of .sup.238U in the radioactive equilibrium samples.</description><subject>Gamma rays</subject><subject>Nuclear energy</subject><subject>Uranium</subject><issn>0236-5731</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqVjU1OwzAUhL0AqeXnAOzeBRzsuHGSJUIg1hVli56S59bUP5HtRuolODNFitijWYy-GY2GsQcpKilE-5il6HXLhWx5s9GSyyu2FrXSvGmVXLGbnL-EEH3XqTX73tJss40BooFwGhxhghEL_nKVT1NVq2YHGMaFar1FMDFBORDITvMjfcAevUee8AwT4fGvHqlQ8jZgWQ5wKHa25Qw2AIXZphg8hYIOMvrJUb5j1wZdpvvFb1n1-vL-_Mb36OjTBhNLwuGikbwdYiBjL_lTI2XbbXot1L8HPy1LYEk</recordid><startdate>20171101</startdate><enddate>20171101</enddate><creator>Vuong, Le Quang</creator><creator>Chuong, Huynh Dinh</creator><creator>Nguyen, Vo Hoang</creator><creator>Hung, Nguyen Quoc</creator><creator>Thanh, Tran Thien</creator><creator>Van Tao, Chau</creator><general>Springer</general><scope/></search><sort><creationdate>20171101</creationdate><title>Revision of nuclear data of .sup.235U and .sup.226Ra for the 186-keV gamma-ray peak for the determination of activity in environmental samples</title><author>Vuong, Le Quang ; Chuong, Huynh Dinh ; Nguyen, Vo Hoang ; Hung, Nguyen Quoc ; Thanh, Tran Thien ; Van Tao, Chau</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-gale_infotracacademiconefile_A5117849603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Gamma rays</topic><topic>Nuclear energy</topic><topic>Uranium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vuong, Le Quang</creatorcontrib><creatorcontrib>Chuong, Huynh Dinh</creatorcontrib><creatorcontrib>Nguyen, Vo Hoang</creatorcontrib><creatorcontrib>Hung, Nguyen Quoc</creatorcontrib><creatorcontrib>Thanh, Tran Thien</creatorcontrib><creatorcontrib>Van Tao, Chau</creatorcontrib><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vuong, Le Quang</au><au>Chuong, Huynh Dinh</au><au>Nguyen, Vo Hoang</au><au>Hung, Nguyen Quoc</au><au>Thanh, Tran Thien</au><au>Van Tao, Chau</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Revision of nuclear data of .sup.235U and .sup.226Ra for the 186-keV gamma-ray peak for the determination of activity in environmental samples</atitle><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle><date>2017-11-01</date><risdate>2017</risdate><volume>314</volume><issue>2</issue><spage>1273</spage><pages>1273-</pages><issn>0236-5731</issn><abstract>In this work, the ratio contribution of .sup.226Ra and .sup.235U in [gamma] spectra with the latest update nuclear data will be revised. The results showed that in the total count rate of the 186 keV peak consists of 57.2% of .sup.226Ra (186.2 keV) and 42.8% of .sup.235U (185.7 keV) with the existence of equilibrium. These calculations were used for determining mass activity of .sup.238U for the direct and fast measurement using only the 186 keV peak and verifying the .sup.238U-.sup.226Ra secular equilibrium. An equilibrium method was measured secular equilibrium of decay chain .sup.238U (by the product daughter .sup.214Bi-609.3 keV) that was used for this study. The maximum relative deviation was less than 4.0% between both methods proved the direct method was reliable and can be applied to determine the mass activity of .sup.238U in the radioactive equilibrium samples.</abstract><pub>Springer</pub><doi>10.1007/s10967-017-5461-1</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0236-5731 |
ispartof | Journal of radioanalytical and nuclear chemistry, 2017-11, Vol.314 (2), p.1273 |
issn | 0236-5731 |
language | eng |
recordid | cdi_gale_infotracacademiconefile_A511784960 |
source | Springer Nature |
subjects | Gamma rays Nuclear energy Uranium |
title | Revision of nuclear data of .sup.235U and .sup.226Ra for the 186-keV gamma-ray peak for the determination of activity in environmental samples |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T14%3A43%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Revision%20of%20nuclear%20data%20of%20.sup.235U%20and%20.sup.226Ra%20for%20the%20186-keV%20gamma-ray%20peak%20for%20the%20determination%20of%20activity%20in%20environmental%20samples&rft.jtitle=Journal%20of%20radioanalytical%20and%20nuclear%20chemistry&rft.au=Vuong,%20Le%20Quang&rft.date=2017-11-01&rft.volume=314&rft.issue=2&rft.spage=1273&rft.pages=1273-&rft.issn=0236-5731&rft_id=info:doi/10.1007/s10967-017-5461-1&rft_dat=%3Cgale%3EA511784960%3C/gale%3E%3Cgrp_id%3Ecdi_FETCH-gale_infotracacademiconefile_A5117849603%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A511784960&rfr_iscdi=true |