An experimental study of cold formed steel trusses using mechanical clinching
The paper describes an investigation into the use of mechanical clinching in cold-formed steel trusses. A series of full-scale tests on trusses with varying configurations of chord and internal members was undertaken. In addition a series of small-scale tests was carried out on samples replicating t...
Saved in:
Published in: | Construction & building materials 2008-05, Vol.22 (5), p.921-931 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The paper describes an investigation into the use of mechanical clinching in cold-formed steel trusses. A series of full-scale tests on trusses with varying configurations of chord and internal members was undertaken. In addition a series of small-scale tests was carried out on samples replicating the nodal connections between the chord and the tie elements of the truss. The results of the small-scale tests are compared with the behaviour of the trusses. The number of clinches has a marked influence on the strength, deformation and failure mode of the trusses. |
---|---|
ISSN: | 0950-0618 1879-0526 |