Loading…
Unsuitable blood glucose measuring devices in neonatal or paediatric acute care
Saved in:
Published in: | South African medical journal 2007-12, Vol.97 (12), p.1231 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 12 |
container_start_page | 1231 |
container_title | South African medical journal |
container_volume | 97 |
creator | Wittenberg, D F Terblanche, A Smuts, I Opperman, J |
description | |
format | article |
fullrecord | <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_gale_infotracmisc_A252090182</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A252090182</galeid><sourcerecordid>A252090182</sourcerecordid><originalsourceid>FETCH-LOGICAL-g276t-6e42fb034c68ba2bf989277becde18022cbbc274f26e1ee590e5f820a3a0fd803</originalsourceid><addsrcrecordid>eNptkM1qwzAQhH1oadK0r1AEhd5cZNmW7WMI_YNALs3ZrKSVoyJLQZILffsa0kIDZQ7LDt8s7FxkS8pqnnd1Uy2y6xg_6LzXHb_KFkXLeMUpXWa7vYuTSSAsEmG9V2Swk_QRyYgQp2DcQBR-GomRGEccegcJLPGBHAGVgRSMJCCnhERCwJvsUoONePszV9n--el985pvdy9vm_U2H1jDU86xYlrQspK8FcCE7tqONY1AqbBoKWNSCMmaSjOOBWLdUax1yyiUQLVqabnK7k93B7DYG6d9CiBHE2W_ZjWjHZ1_nKnHf6hZCkcjvUNtZv8s8PAncECw6RC9nZLxLp6DdyfwOIkRVX8MZoTw1f82W34DVOhygA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Unsuitable blood glucose measuring devices in neonatal or paediatric acute care</title><source>DOAJ Directory of Open Access Journals</source><creator>Wittenberg, D F ; Terblanche, A ; Smuts, I ; Opperman, J</creator><creatorcontrib>Wittenberg, D F ; Terblanche, A ; Smuts, I ; Opperman, J</creatorcontrib><identifier>ISSN: 0256-9574</identifier><identifier>PMID: 18264600</identifier><language>eng</language><publisher>South Africa: Health & Medical Publishing Group</publisher><subject>Blood Glucose - metabolism ; Blood sugar ; Diagnostic Techniques and Procedures - instrumentation ; Equipment Design ; Evaluation ; Female ; Galactosemias - blood ; Galactosemias - diagnosis ; Glucose monitors ; Humans ; Infant, Newborn ; Intensive Care Units, Neonatal - supply & distribution ; Measurement ; Methods ; Pediatric intensive care</subject><ispartof>South African medical journal, 2007-12, Vol.97 (12), p.1231</ispartof><rights>COPYRIGHT 2007 Health & Medical Publishing Group</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18264600$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wittenberg, D F</creatorcontrib><creatorcontrib>Terblanche, A</creatorcontrib><creatorcontrib>Smuts, I</creatorcontrib><creatorcontrib>Opperman, J</creatorcontrib><title>Unsuitable blood glucose measuring devices in neonatal or paediatric acute care</title><title>South African medical journal</title><addtitle>S Afr Med J</addtitle><subject>Blood Glucose - metabolism</subject><subject>Blood sugar</subject><subject>Diagnostic Techniques and Procedures - instrumentation</subject><subject>Equipment Design</subject><subject>Evaluation</subject><subject>Female</subject><subject>Galactosemias - blood</subject><subject>Galactosemias - diagnosis</subject><subject>Glucose monitors</subject><subject>Humans</subject><subject>Infant, Newborn</subject><subject>Intensive Care Units, Neonatal - supply & distribution</subject><subject>Measurement</subject><subject>Methods</subject><subject>Pediatric intensive care</subject><issn>0256-9574</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNptkM1qwzAQhH1oadK0r1AEhd5cZNmW7WMI_YNALs3ZrKSVoyJLQZILffsa0kIDZQ7LDt8s7FxkS8pqnnd1Uy2y6xg_6LzXHb_KFkXLeMUpXWa7vYuTSSAsEmG9V2Swk_QRyYgQp2DcQBR-GomRGEccegcJLPGBHAGVgRSMJCCnhERCwJvsUoONePszV9n--el985pvdy9vm_U2H1jDU86xYlrQspK8FcCE7tqONY1AqbBoKWNSCMmaSjOOBWLdUax1yyiUQLVqabnK7k93B7DYG6d9CiBHE2W_ZjWjHZ1_nKnHf6hZCkcjvUNtZv8s8PAncECw6RC9nZLxLp6DdyfwOIkRVX8MZoTw1f82W34DVOhygA</recordid><startdate>200712</startdate><enddate>200712</enddate><creator>Wittenberg, D F</creator><creator>Terblanche, A</creator><creator>Smuts, I</creator><creator>Opperman, J</creator><general>Health & Medical Publishing Group</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope></search><sort><creationdate>200712</creationdate><title>Unsuitable blood glucose measuring devices in neonatal or paediatric acute care</title><author>Wittenberg, D F ; Terblanche, A ; Smuts, I ; Opperman, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g276t-6e42fb034c68ba2bf989277becde18022cbbc274f26e1ee590e5f820a3a0fd803</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Blood Glucose - metabolism</topic><topic>Blood sugar</topic><topic>Diagnostic Techniques and Procedures - instrumentation</topic><topic>Equipment Design</topic><topic>Evaluation</topic><topic>Female</topic><topic>Galactosemias - blood</topic><topic>Galactosemias - diagnosis</topic><topic>Glucose monitors</topic><topic>Humans</topic><topic>Infant, Newborn</topic><topic>Intensive Care Units, Neonatal - supply & distribution</topic><topic>Measurement</topic><topic>Methods</topic><topic>Pediatric intensive care</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wittenberg, D F</creatorcontrib><creatorcontrib>Terblanche, A</creatorcontrib><creatorcontrib>Smuts, I</creatorcontrib><creatorcontrib>Opperman, J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><jtitle>South African medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wittenberg, D F</au><au>Terblanche, A</au><au>Smuts, I</au><au>Opperman, J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Unsuitable blood glucose measuring devices in neonatal or paediatric acute care</atitle><jtitle>South African medical journal</jtitle><addtitle>S Afr Med J</addtitle><date>2007-12</date><risdate>2007</risdate><volume>97</volume><issue>12</issue><spage>1231</spage><pages>1231-</pages><issn>0256-9574</issn><cop>South Africa</cop><pub>Health & Medical Publishing Group</pub><pmid>18264600</pmid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0256-9574 |
ispartof | South African medical journal, 2007-12, Vol.97 (12), p.1231 |
issn | 0256-9574 |
language | eng |
recordid | cdi_gale_infotracmisc_A252090182 |
source | DOAJ Directory of Open Access Journals |
subjects | Blood Glucose - metabolism Blood sugar Diagnostic Techniques and Procedures - instrumentation Equipment Design Evaluation Female Galactosemias - blood Galactosemias - diagnosis Glucose monitors Humans Infant, Newborn Intensive Care Units, Neonatal - supply & distribution Measurement Methods Pediatric intensive care |
title | Unsuitable blood glucose measuring devices in neonatal or paediatric acute care |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T23%3A50%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Unsuitable%20blood%20glucose%20measuring%20devices%20in%20neonatal%20or%20paediatric%20acute%20care&rft.jtitle=South%20African%20medical%20journal&rft.au=Wittenberg,%20D%20F&rft.date=2007-12&rft.volume=97&rft.issue=12&rft.spage=1231&rft.pages=1231-&rft.issn=0256-9574&rft_id=info:doi/&rft_dat=%3Cgale_pubme%3EA252090182%3C/gale_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-g276t-6e42fb034c68ba2bf989277becde18022cbbc274f26e1ee590e5f820a3a0fd803%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/18264600&rft_galeid=A252090182&rfr_iscdi=true |