Repeatability and reproducibility of anterior segment measurements in normal eyes using dual Scheimpflug analyzer
Objectives: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. Materials and Methods: Three repeated consecutive measurements were taken by two independent exami...
Saved in:
Published in: | Turk oftalmoloji gazetesi 2015-11, Vol.45 (6), p.243 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 6 |
container_start_page | 243 |
container_title | Turk oftalmoloji gazetesi |
container_volume | 45 |
creator | Altiparmak, Zeynep Yagci, Ramazan Guler, Emre Arslanyilmaz, Zeynel Canbal, Metin Hepsen, Ibrahim F |
description | Objectives: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. Materials and Methods: Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the withinsubject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. Results: Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. Conclusion: The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes. Keywords: Galilei, intraobserver, interobserver repeatability, wavefront aberrations |
doi_str_mv | 10.4274/tjo.l6768 |
format | article |
fullrecord | <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A443011693</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A443011693</galeid><sourcerecordid>A443011693</sourcerecordid><originalsourceid>FETCH-LOGICAL-g673-ac94e46d16ced6b2a4debb3ba5a33c3222ffc0fa2b897cfb8e1657feb4d1d5783</originalsourceid><addsrcrecordid>eNptjEtPwzAQhH0Aiar0wD-wxDnFsR07OVYVLwkJCXqv_FgHV45d7ORQfj1B9MCBncPufpoZhG5qsuZU8rvxkNZBSNFeoEXNCKmIaLortCrlQOZpaCtFs0Cfb3AENSrtgx9PWEWLMxxzspPxZ5bcjEfIPmVcoB8gjngAVaYMP3fBPuKY8qAChhMUPBUfe2yn-X83H-CHowtTP3eocPqCfI0unQoFVue9RLuH-932qXp5fXzebl6qXkhWKdNx4MLWwoAVmipuQWumVaMYM4xS6pwhTlHddtI43UItGulAc1vbRrZsiW5_a3sVYO-jS2NWZvDF7DecM1LXomOza_2Pa5aFwZsUwfmZ_wl8A_apbXk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Repeatability and reproducibility of anterior segment measurements in normal eyes using dual Scheimpflug analyzer</title><source>Publicly Available Content (ProQuest)</source><creator>Altiparmak, Zeynep ; Yagci, Ramazan ; Guler, Emre ; Arslanyilmaz, Zeynel ; Canbal, Metin ; Hepsen, Ibrahim F</creator><creatorcontrib>Altiparmak, Zeynep ; Yagci, Ramazan ; Guler, Emre ; Arslanyilmaz, Zeynel ; Canbal, Metin ; Hepsen, Ibrahim F</creatorcontrib><description>Objectives: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. Materials and Methods: Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the withinsubject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. Results: Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. Conclusion: The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes. Keywords: Galilei, intraobserver, interobserver repeatability, wavefront aberrations</description><identifier>ISSN: 1300-0659</identifier><identifier>DOI: 10.4274/tjo.l6768</identifier><language>eng</language><publisher>Galenos Yayinevi Tic. Ltd</publisher><subject>Aberration (Optics) ; Astigmatism ; Care and treatment ; Eye diseases ; Risk factors ; Topography</subject><ispartof>Turk oftalmoloji gazetesi, 2015-11, Vol.45 (6), p.243</ispartof><rights>COPYRIGHT 2015 Galenos Yayinevi Tic. Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Altiparmak, Zeynep</creatorcontrib><creatorcontrib>Yagci, Ramazan</creatorcontrib><creatorcontrib>Guler, Emre</creatorcontrib><creatorcontrib>Arslanyilmaz, Zeynel</creatorcontrib><creatorcontrib>Canbal, Metin</creatorcontrib><creatorcontrib>Hepsen, Ibrahim F</creatorcontrib><title>Repeatability and reproducibility of anterior segment measurements in normal eyes using dual Scheimpflug analyzer</title><title>Turk oftalmoloji gazetesi</title><description>Objectives: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. Materials and Methods: Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the withinsubject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. Results: Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. Conclusion: The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes. Keywords: Galilei, intraobserver, interobserver repeatability, wavefront aberrations</description><subject>Aberration (Optics)</subject><subject>Astigmatism</subject><subject>Care and treatment</subject><subject>Eye diseases</subject><subject>Risk factors</subject><subject>Topography</subject><issn>1300-0659</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNptjEtPwzAQhH0Aiar0wD-wxDnFsR07OVYVLwkJCXqv_FgHV45d7ORQfj1B9MCBncPufpoZhG5qsuZU8rvxkNZBSNFeoEXNCKmIaLortCrlQOZpaCtFs0Cfb3AENSrtgx9PWEWLMxxzspPxZ5bcjEfIPmVcoB8gjngAVaYMP3fBPuKY8qAChhMUPBUfe2yn-X83H-CHowtTP3eocPqCfI0unQoFVue9RLuH-932qXp5fXzebl6qXkhWKdNx4MLWwoAVmipuQWumVaMYM4xS6pwhTlHddtI43UItGulAc1vbRrZsiW5_a3sVYO-jS2NWZvDF7DecM1LXomOza_2Pa5aFwZsUwfmZ_wl8A_apbXk</recordid><startdate>20151101</startdate><enddate>20151101</enddate><creator>Altiparmak, Zeynep</creator><creator>Yagci, Ramazan</creator><creator>Guler, Emre</creator><creator>Arslanyilmaz, Zeynel</creator><creator>Canbal, Metin</creator><creator>Hepsen, Ibrahim F</creator><general>Galenos Yayinevi Tic. Ltd</general><scope/></search><sort><creationdate>20151101</creationdate><title>Repeatability and reproducibility of anterior segment measurements in normal eyes using dual Scheimpflug analyzer</title><author>Altiparmak, Zeynep ; Yagci, Ramazan ; Guler, Emre ; Arslanyilmaz, Zeynel ; Canbal, Metin ; Hepsen, Ibrahim F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g673-ac94e46d16ced6b2a4debb3ba5a33c3222ffc0fa2b897cfb8e1657feb4d1d5783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Aberration (Optics)</topic><topic>Astigmatism</topic><topic>Care and treatment</topic><topic>Eye diseases</topic><topic>Risk factors</topic><topic>Topography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Altiparmak, Zeynep</creatorcontrib><creatorcontrib>Yagci, Ramazan</creatorcontrib><creatorcontrib>Guler, Emre</creatorcontrib><creatorcontrib>Arslanyilmaz, Zeynel</creatorcontrib><creatorcontrib>Canbal, Metin</creatorcontrib><creatorcontrib>Hepsen, Ibrahim F</creatorcontrib><jtitle>Turk oftalmoloji gazetesi</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Altiparmak, Zeynep</au><au>Yagci, Ramazan</au><au>Guler, Emre</au><au>Arslanyilmaz, Zeynel</au><au>Canbal, Metin</au><au>Hepsen, Ibrahim F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Repeatability and reproducibility of anterior segment measurements in normal eyes using dual Scheimpflug analyzer</atitle><jtitle>Turk oftalmoloji gazetesi</jtitle><date>2015-11-01</date><risdate>2015</risdate><volume>45</volume><issue>6</issue><spage>243</spage><pages>243-</pages><issn>1300-0659</issn><abstract>Objectives: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. Materials and Methods: Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the withinsubject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. Results: Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. Conclusion: The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes. Keywords: Galilei, intraobserver, interobserver repeatability, wavefront aberrations</abstract><pub>Galenos Yayinevi Tic. Ltd</pub><doi>10.4274/tjo.l6768</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1300-0659 |
ispartof | Turk oftalmoloji gazetesi, 2015-11, Vol.45 (6), p.243 |
issn | 1300-0659 |
language | eng |
recordid | cdi_gale_infotracmisc_A443011693 |
source | Publicly Available Content (ProQuest) |
subjects | Aberration (Optics) Astigmatism Care and treatment Eye diseases Risk factors Topography |
title | Repeatability and reproducibility of anterior segment measurements in normal eyes using dual Scheimpflug analyzer |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T14%3A39%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Repeatability%20and%20reproducibility%20of%20anterior%20segment%20measurements%20in%20normal%20eyes%20using%20dual%20Scheimpflug%20analyzer&rft.jtitle=Turk%20oftalmoloji%20gazetesi&rft.au=Altiparmak,%20Zeynep&rft.date=2015-11-01&rft.volume=45&rft.issue=6&rft.spage=243&rft.pages=243-&rft.issn=1300-0659&rft_id=info:doi/10.4274/tjo.l6768&rft_dat=%3Cgale%3EA443011693%3C/gale%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-g673-ac94e46d16ced6b2a4debb3ba5a33c3222ffc0fa2b897cfb8e1657feb4d1d5783%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A443011693&rfr_iscdi=true |