Research using GPR into the cause of cracks and depressions in the floor of the gallery of Hagia Sophia Museum

•Hagia Sophia is a important historical buildings in Istanbul.•The main dome of Hagia Sophia collapsed several times.•Mimar Sinan made the main reinforcement in the 16th century.•Currently the presence of deformations is on the floor of the gallery.•Hagia Sophia Museum was scanned with ground penetr...

Full description

Saved in:
Bibliographic Details
Published in:Construction & building materials 2017-05, Vol.139, p.458-466
Main Authors: Yalçıner, Cahit Çağlar, Kurban, Yunus Can, Altunel, Erhan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c463t-f8018b6317de48c4712b0ba26767e711037cbce904eac632bd4c333d5cea27cc3
cites cdi_FETCH-LOGICAL-c463t-f8018b6317de48c4712b0ba26767e711037cbce904eac632bd4c333d5cea27cc3
container_end_page 466
container_issue
container_start_page 458
container_title Construction & building materials
container_volume 139
creator Yalçıner, Cahit Çağlar
Kurban, Yunus Can
Altunel, Erhan
description •Hagia Sophia is a important historical buildings in Istanbul.•The main dome of Hagia Sophia collapsed several times.•Mimar Sinan made the main reinforcement in the 16th century.•Currently the presence of deformations is on the floor of the gallery.•Hagia Sophia Museum was scanned with ground penetrating radar. Hagia Sophia Museum is one of Istanbul's most important historical structures. Considering its location in Istanbul and the use of the building through history, visible damage is noted in the structure. To determine whether this damage noted on the exterior of the building is present in the interior, the gallery of Hagia Sophia Museum was scanned with ground penetrating radar. The GPR scanning of the floor of the gallery revealed the presence of weak zones in the floor and varying scales of deformation within the structure. Detailed study of the vaults showed that the geometrical symmetry of the curve of the vault dome was disrupted. The results obtained in this study show that necessary precautions should be urgently completed to prevent damage to Hagia Sophia, especially when the earthquake expected near Istanbul is considered.
doi_str_mv 10.1016/j.conbuildmat.2017.02.036
format article
fullrecord <record><control><sourceid>gale_cross</sourceid><recordid>TN_cdi_gale_infotracmisc_A493793851</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A493793851</galeid><els_id>S0950061817302192</els_id><sourcerecordid>A493793851</sourcerecordid><originalsourceid>FETCH-LOGICAL-c463t-f8018b6317de48c4712b0ba26767e711037cbce904eac632bd4c333d5cea27cc3</originalsourceid><addsrcrecordid>eNqNkV-L1DAUxYMoOK5-h4ivtuZPJ2kfl0F3hRVl1eeQ3tx2MrbJkHSE_famjg-7MA-Sh8sNv3NIziHkLWc1Z1x9ONQQQ3_yk5vtUgvGdc1EzaR6Rja81V3FtkI9JxvWbVnFFG9fklc5HxhjSiixIeEeM9oEe3rKPoz05ts99WGJdNkjBXvKSONAIVn4lakNjjo8JszZx5AL-BcbphjTiq3LaKcJ08O63trRW_o9HvdlfClWp_k1eTHYKeObf_OK_Pz08cfutrr7evN5d31XQaPkUg0t422vJNcOmxYazUXPeiuUVho150xq6AE71qAFJUXvGpBSui2gFRpAXpF3Z9_yHDQ-DHEpX5h9BnPddFJ3st3yQlUXqBEDJjvFgIMv10_4-gJfjsPZw0XB-0eCfo14zS5kP-6XPJZ481O8O-OQYs4JB3NMfrbpwXBm1rrNwTyq26x1GyZMqbtod2ctllh_e0wmg8cA6HxCWIyL_j9c_gARUrhz</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Research using GPR into the cause of cracks and depressions in the floor of the gallery of Hagia Sophia Museum</title><source>ScienceDirect Journals</source><creator>Yalçıner, Cahit Çağlar ; Kurban, Yunus Can ; Altunel, Erhan</creator><creatorcontrib>Yalçıner, Cahit Çağlar ; Kurban, Yunus Can ; Altunel, Erhan</creatorcontrib><description>•Hagia Sophia is a important historical buildings in Istanbul.•The main dome of Hagia Sophia collapsed several times.•Mimar Sinan made the main reinforcement in the 16th century.•Currently the presence of deformations is on the floor of the gallery.•Hagia Sophia Museum was scanned with ground penetrating radar. Hagia Sophia Museum is one of Istanbul's most important historical structures. Considering its location in Istanbul and the use of the building through history, visible damage is noted in the structure. To determine whether this damage noted on the exterior of the building is present in the interior, the gallery of Hagia Sophia Museum was scanned with ground penetrating radar. The GPR scanning of the floor of the gallery revealed the presence of weak zones in the floor and varying scales of deformation within the structure. Detailed study of the vaults showed that the geometrical symmetry of the curve of the vault dome was disrupted. The results obtained in this study show that necessary precautions should be urgently completed to prevent damage to Hagia Sophia, especially when the earthquake expected near Istanbul is considered.</description><identifier>ISSN: 0950-0618</identifier><identifier>EISSN: 1879-0526</identifier><identifier>DOI: 10.1016/j.conbuildmat.2017.02.036</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Floor depressions ; GPR ; Ground penetrating radar ; Hagia Sophia Museum ; Measurement ; Metal reinforcement ; Museums ; Reinforcing bars ; Tile flooring ; Vaults ; Vaults (Architecture)</subject><ispartof>Construction &amp; building materials, 2017-05, Vol.139, p.458-466</ispartof><rights>2017 Elsevier Ltd</rights><rights>COPYRIGHT 2017 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c463t-f8018b6317de48c4712b0ba26767e711037cbce904eac632bd4c333d5cea27cc3</citedby><cites>FETCH-LOGICAL-c463t-f8018b6317de48c4712b0ba26767e711037cbce904eac632bd4c333d5cea27cc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Yalçıner, Cahit Çağlar</creatorcontrib><creatorcontrib>Kurban, Yunus Can</creatorcontrib><creatorcontrib>Altunel, Erhan</creatorcontrib><title>Research using GPR into the cause of cracks and depressions in the floor of the gallery of Hagia Sophia Museum</title><title>Construction &amp; building materials</title><description>•Hagia Sophia is a important historical buildings in Istanbul.•The main dome of Hagia Sophia collapsed several times.•Mimar Sinan made the main reinforcement in the 16th century.•Currently the presence of deformations is on the floor of the gallery.•Hagia Sophia Museum was scanned with ground penetrating radar. Hagia Sophia Museum is one of Istanbul's most important historical structures. Considering its location in Istanbul and the use of the building through history, visible damage is noted in the structure. To determine whether this damage noted on the exterior of the building is present in the interior, the gallery of Hagia Sophia Museum was scanned with ground penetrating radar. The GPR scanning of the floor of the gallery revealed the presence of weak zones in the floor and varying scales of deformation within the structure. Detailed study of the vaults showed that the geometrical symmetry of the curve of the vault dome was disrupted. The results obtained in this study show that necessary precautions should be urgently completed to prevent damage to Hagia Sophia, especially when the earthquake expected near Istanbul is considered.</description><subject>Floor depressions</subject><subject>GPR</subject><subject>Ground penetrating radar</subject><subject>Hagia Sophia Museum</subject><subject>Measurement</subject><subject>Metal reinforcement</subject><subject>Museums</subject><subject>Reinforcing bars</subject><subject>Tile flooring</subject><subject>Vaults</subject><subject>Vaults (Architecture)</subject><issn>0950-0618</issn><issn>1879-0526</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqNkV-L1DAUxYMoOK5-h4ivtuZPJ2kfl0F3hRVl1eeQ3tx2MrbJkHSE_famjg-7MA-Sh8sNv3NIziHkLWc1Z1x9ONQQQ3_yk5vtUgvGdc1EzaR6Rja81V3FtkI9JxvWbVnFFG9fklc5HxhjSiixIeEeM9oEe3rKPoz05ts99WGJdNkjBXvKSONAIVn4lakNjjo8JszZx5AL-BcbphjTiq3LaKcJ08O63trRW_o9HvdlfClWp_k1eTHYKeObf_OK_Pz08cfutrr7evN5d31XQaPkUg0t422vJNcOmxYazUXPeiuUVho150xq6AE71qAFJUXvGpBSui2gFRpAXpF3Z9_yHDQ-DHEpX5h9BnPddFJ3st3yQlUXqBEDJjvFgIMv10_4-gJfjsPZw0XB-0eCfo14zS5kP-6XPJZ481O8O-OQYs4JB3NMfrbpwXBm1rrNwTyq26x1GyZMqbtod2ctllh_e0wmg8cA6HxCWIyL_j9c_gARUrhz</recordid><startdate>20170515</startdate><enddate>20170515</enddate><creator>Yalçıner, Cahit Çağlar</creator><creator>Kurban, Yunus Can</creator><creator>Altunel, Erhan</creator><general>Elsevier Ltd</general><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>N95</scope><scope>XI7</scope></search><sort><creationdate>20170515</creationdate><title>Research using GPR into the cause of cracks and depressions in the floor of the gallery of Hagia Sophia Museum</title><author>Yalçıner, Cahit Çağlar ; Kurban, Yunus Can ; Altunel, Erhan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c463t-f8018b6317de48c4712b0ba26767e711037cbce904eac632bd4c333d5cea27cc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Floor depressions</topic><topic>GPR</topic><topic>Ground penetrating radar</topic><topic>Hagia Sophia Museum</topic><topic>Measurement</topic><topic>Metal reinforcement</topic><topic>Museums</topic><topic>Reinforcing bars</topic><topic>Tile flooring</topic><topic>Vaults</topic><topic>Vaults (Architecture)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yalçıner, Cahit Çağlar</creatorcontrib><creatorcontrib>Kurban, Yunus Can</creatorcontrib><creatorcontrib>Altunel, Erhan</creatorcontrib><collection>CrossRef</collection><collection>Gale Business: Insights</collection><collection>Business Insights: Essentials</collection><jtitle>Construction &amp; building materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yalçıner, Cahit Çağlar</au><au>Kurban, Yunus Can</au><au>Altunel, Erhan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Research using GPR into the cause of cracks and depressions in the floor of the gallery of Hagia Sophia Museum</atitle><jtitle>Construction &amp; building materials</jtitle><date>2017-05-15</date><risdate>2017</risdate><volume>139</volume><spage>458</spage><epage>466</epage><pages>458-466</pages><issn>0950-0618</issn><eissn>1879-0526</eissn><abstract>•Hagia Sophia is a important historical buildings in Istanbul.•The main dome of Hagia Sophia collapsed several times.•Mimar Sinan made the main reinforcement in the 16th century.•Currently the presence of deformations is on the floor of the gallery.•Hagia Sophia Museum was scanned with ground penetrating radar. Hagia Sophia Museum is one of Istanbul's most important historical structures. Considering its location in Istanbul and the use of the building through history, visible damage is noted in the structure. To determine whether this damage noted on the exterior of the building is present in the interior, the gallery of Hagia Sophia Museum was scanned with ground penetrating radar. The GPR scanning of the floor of the gallery revealed the presence of weak zones in the floor and varying scales of deformation within the structure. Detailed study of the vaults showed that the geometrical symmetry of the curve of the vault dome was disrupted. The results obtained in this study show that necessary precautions should be urgently completed to prevent damage to Hagia Sophia, especially when the earthquake expected near Istanbul is considered.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.conbuildmat.2017.02.036</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0950-0618
ispartof Construction & building materials, 2017-05, Vol.139, p.458-466
issn 0950-0618
1879-0526
language eng
recordid cdi_gale_infotracmisc_A493793851
source ScienceDirect Journals
subjects Floor depressions
GPR
Ground penetrating radar
Hagia Sophia Museum
Measurement
Metal reinforcement
Museums
Reinforcing bars
Tile flooring
Vaults
Vaults (Architecture)
title Research using GPR into the cause of cracks and depressions in the floor of the gallery of Hagia Sophia Museum
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T13%3A16%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Research%20using%20GPR%20into%20the%20cause%20of%20cracks%20and%20depressions%20in%20the%20floor%20of%20the%20gallery%20of%20Hagia%20Sophia%20Museum&rft.jtitle=Construction%20&%20building%20materials&rft.au=Yal%C3%A7%C4%B1ner,%20Cahit%20%C3%87a%C4%9Flar&rft.date=2017-05-15&rft.volume=139&rft.spage=458&rft.epage=466&rft.pages=458-466&rft.issn=0950-0618&rft.eissn=1879-0526&rft_id=info:doi/10.1016/j.conbuildmat.2017.02.036&rft_dat=%3Cgale_cross%3EA493793851%3C/gale_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c463t-f8018b6317de48c4712b0ba26767e711037cbce904eac632bd4c333d5cea27cc3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A493793851&rfr_iscdi=true