Uniaxial behavior of circular ultra-high-performance fiber-reinforced concrete columns confined by spiral reinforcement

•Circular UHPFRC columns with varying spiral spacing and concrete strength were tested.•Circular UHPFRC columns detailed with different code provisions were investigated.•The efficiency of circular spirals and square hoops on confinement were compared.•Steel fibers in UHPFRC allowed for gradual spal...

Full description

Saved in:
Bibliographic Details
Published in:Construction & building materials 2018-04, Vol.168, p.379-393
Main Authors: Shin, Hyun-Oh, Min, Kyung-Hwan, Mitchell, Denis
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c463t-7b5fc82838b4ce9d93ef4ac3f70632f21140001e37a40406d3c25c6f48b9bc553
cites cdi_FETCH-LOGICAL-c463t-7b5fc82838b4ce9d93ef4ac3f70632f21140001e37a40406d3c25c6f48b9bc553
container_end_page 393
container_issue
container_start_page 379
container_title Construction & building materials
container_volume 168
creator Shin, Hyun-Oh
Min, Kyung-Hwan
Mitchell, Denis
description •Circular UHPFRC columns with varying spiral spacing and concrete strength were tested.•Circular UHPFRC columns detailed with different code provisions were investigated.•The efficiency of circular spirals and square hoops on confinement were compared.•Steel fibers in UHPFRC allowed for gradual spalling and high damage tolerance.•A design recommendation for spiral reinforcement in UHPFRC columns is proposed. This paper presents results from the uniaxial tests of six large-scale ultra-high-performance fiber-reinforced concrete (UHPFRC) circular columns confined by spirals. The UHPFRC used in this study had 1.5% of hybrid micro-steel fibers (1.0% of 19.5 mm fibers and 0.5% of 16.3 mm fibers) in the mixture and had compressive strengths varying from 163 to 181 MPa. The effects of the volumetric ratio of spiral reinforcement, compressive strength of concrete, and presence of hybrid micro-steel fibers on the axial load responses, including post-peak deformability, were investigated. In addition, the ductility level reached by circular UHPFRC columns designed according to the minimum spiral reinforcement of current design provisions of the CSA A23.3-14 Standard and the ACI 318-14 Code were evaluated to investigate the applicability of these equations to UHPFRC columns. Test results showed that the combined effect of the minimum spiral reinforcement and steel fibers resulted in sufficient post-peak ductility of the UHPFRC columns. To investigate the efficiency of the shape of the confinement reinforcement, the test results of the circular UHPFRC columns confined by spirals were compared with those from equivalent-sized square UHPFRC columns confined by hoops. The test results demonstrate the superior performance of circular spirals for developing the ductile behavior of UHPFRC columns than the same volumetric ratio of rectilinear hoops. A design recommendation for spiral reinforcement that ensures the ductile behavior of UHPFRC columns in moderate seismic regions is proposed.
doi_str_mv 10.1016/j.conbuildmat.2018.02.073
format article
fullrecord <record><control><sourceid>gale_cross</sourceid><recordid>TN_cdi_gale_infotracmisc_A538858541</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A538858541</galeid><els_id>S0950061818303167</els_id><sourcerecordid>A538858541</sourcerecordid><originalsourceid>FETCH-LOGICAL-c463t-7b5fc82838b4ce9d93ef4ac3f70632f21140001e37a40406d3c25c6f48b9bc553</originalsourceid><addsrcrecordid>eNqNkU1r3DAQhkVpIds0_8Gl18rVh2XLx7C0TSHQS3MW0ni0q8WWF8lOm39fLVtCAnsoAkmMnnc0My8hHzmrOePtl0MNc3RrGIfJLrVgXNdM1KyTb8iG666nTIn2LdmwXjHKWq6vyPucD4yxVrRiQ34_xGD_BDtWDvf2Mcypmn0FIcE62lSt45Is3Yfdnh4x-TlNNgJWPjhMNGGIJQQ4VKUISLhguYzrFPMp4EMsL-6pyseQygfP-IRx-UDeeTtmvPl3XpOHb19_be_o_c_vP7a39xSaVi60c8qDFlpq1wD2Qy_RNxak71grhRecN6UVjrKzDWtYO0gQClrfaNc7UEpek0_nvDs7ojkVUBqCKWQwt0pqrbRqeKHoBWqHEUvhc0QfSvgVX1_gyxpwCnBR8PmFwK25zCaXLZfJLnln15xf4_0ZhzTnnNCbYwqTTU-GM3Py3RzMC9_NyXfDhCm-F-32rMUy1seAyWQIWFwbQkJYzDCH_8jyF8gbveM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Uniaxial behavior of circular ultra-high-performance fiber-reinforced concrete columns confined by spiral reinforcement</title><source>Elsevier</source><creator>Shin, Hyun-Oh ; Min, Kyung-Hwan ; Mitchell, Denis</creator><creatorcontrib>Shin, Hyun-Oh ; Min, Kyung-Hwan ; Mitchell, Denis</creatorcontrib><description>•Circular UHPFRC columns with varying spiral spacing and concrete strength were tested.•Circular UHPFRC columns detailed with different code provisions were investigated.•The efficiency of circular spirals and square hoops on confinement were compared.•Steel fibers in UHPFRC allowed for gradual spalling and high damage tolerance.•A design recommendation for spiral reinforcement in UHPFRC columns is proposed. This paper presents results from the uniaxial tests of six large-scale ultra-high-performance fiber-reinforced concrete (UHPFRC) circular columns confined by spirals. The UHPFRC used in this study had 1.5% of hybrid micro-steel fibers (1.0% of 19.5 mm fibers and 0.5% of 16.3 mm fibers) in the mixture and had compressive strengths varying from 163 to 181 MPa. The effects of the volumetric ratio of spiral reinforcement, compressive strength of concrete, and presence of hybrid micro-steel fibers on the axial load responses, including post-peak deformability, were investigated. In addition, the ductility level reached by circular UHPFRC columns designed according to the minimum spiral reinforcement of current design provisions of the CSA A23.3-14 Standard and the ACI 318-14 Code were evaluated to investigate the applicability of these equations to UHPFRC columns. Test results showed that the combined effect of the minimum spiral reinforcement and steel fibers resulted in sufficient post-peak ductility of the UHPFRC columns. To investigate the efficiency of the shape of the confinement reinforcement, the test results of the circular UHPFRC columns confined by spirals were compared with those from equivalent-sized square UHPFRC columns confined by hoops. The test results demonstrate the superior performance of circular spirals for developing the ductile behavior of UHPFRC columns than the same volumetric ratio of rectilinear hoops. A design recommendation for spiral reinforcement that ensures the ductile behavior of UHPFRC columns in moderate seismic regions is proposed.</description><identifier>ISSN: 0950-0618</identifier><identifier>EISSN: 1879-0526</identifier><identifier>DOI: 10.1016/j.conbuildmat.2018.02.073</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Circular column ; Ductile behavior ; Fiber reinforced concrete ; Properties ; Spiral reinforcement ; Ultra-high-performance fiber-reinforced concrete</subject><ispartof>Construction &amp; building materials, 2018-04, Vol.168, p.379-393</ispartof><rights>2018 Elsevier Ltd</rights><rights>COPYRIGHT 2018 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c463t-7b5fc82838b4ce9d93ef4ac3f70632f21140001e37a40406d3c25c6f48b9bc553</citedby><cites>FETCH-LOGICAL-c463t-7b5fc82838b4ce9d93ef4ac3f70632f21140001e37a40406d3c25c6f48b9bc553</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Shin, Hyun-Oh</creatorcontrib><creatorcontrib>Min, Kyung-Hwan</creatorcontrib><creatorcontrib>Mitchell, Denis</creatorcontrib><title>Uniaxial behavior of circular ultra-high-performance fiber-reinforced concrete columns confined by spiral reinforcement</title><title>Construction &amp; building materials</title><description>•Circular UHPFRC columns with varying spiral spacing and concrete strength were tested.•Circular UHPFRC columns detailed with different code provisions were investigated.•The efficiency of circular spirals and square hoops on confinement were compared.•Steel fibers in UHPFRC allowed for gradual spalling and high damage tolerance.•A design recommendation for spiral reinforcement in UHPFRC columns is proposed. This paper presents results from the uniaxial tests of six large-scale ultra-high-performance fiber-reinforced concrete (UHPFRC) circular columns confined by spirals. The UHPFRC used in this study had 1.5% of hybrid micro-steel fibers (1.0% of 19.5 mm fibers and 0.5% of 16.3 mm fibers) in the mixture and had compressive strengths varying from 163 to 181 MPa. The effects of the volumetric ratio of spiral reinforcement, compressive strength of concrete, and presence of hybrid micro-steel fibers on the axial load responses, including post-peak deformability, were investigated. In addition, the ductility level reached by circular UHPFRC columns designed according to the minimum spiral reinforcement of current design provisions of the CSA A23.3-14 Standard and the ACI 318-14 Code were evaluated to investigate the applicability of these equations to UHPFRC columns. Test results showed that the combined effect of the minimum spiral reinforcement and steel fibers resulted in sufficient post-peak ductility of the UHPFRC columns. To investigate the efficiency of the shape of the confinement reinforcement, the test results of the circular UHPFRC columns confined by spirals were compared with those from equivalent-sized square UHPFRC columns confined by hoops. The test results demonstrate the superior performance of circular spirals for developing the ductile behavior of UHPFRC columns than the same volumetric ratio of rectilinear hoops. A design recommendation for spiral reinforcement that ensures the ductile behavior of UHPFRC columns in moderate seismic regions is proposed.</description><subject>Circular column</subject><subject>Ductile behavior</subject><subject>Fiber reinforced concrete</subject><subject>Properties</subject><subject>Spiral reinforcement</subject><subject>Ultra-high-performance fiber-reinforced concrete</subject><issn>0950-0618</issn><issn>1879-0526</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNkU1r3DAQhkVpIds0_8Gl18rVh2XLx7C0TSHQS3MW0ni0q8WWF8lOm39fLVtCAnsoAkmMnnc0My8hHzmrOePtl0MNc3RrGIfJLrVgXNdM1KyTb8iG666nTIn2LdmwXjHKWq6vyPucD4yxVrRiQ34_xGD_BDtWDvf2Mcypmn0FIcE62lSt45Is3Yfdnh4x-TlNNgJWPjhMNGGIJQQ4VKUISLhguYzrFPMp4EMsL-6pyseQygfP-IRx-UDeeTtmvPl3XpOHb19_be_o_c_vP7a39xSaVi60c8qDFlpq1wD2Qy_RNxak71grhRecN6UVjrKzDWtYO0gQClrfaNc7UEpek0_nvDs7ojkVUBqCKWQwt0pqrbRqeKHoBWqHEUvhc0QfSvgVX1_gyxpwCnBR8PmFwK25zCaXLZfJLnln15xf4_0ZhzTnnNCbYwqTTU-GM3Py3RzMC9_NyXfDhCm-F-32rMUy1seAyWQIWFwbQkJYzDCH_8jyF8gbveM</recordid><startdate>20180420</startdate><enddate>20180420</enddate><creator>Shin, Hyun-Oh</creator><creator>Min, Kyung-Hwan</creator><creator>Mitchell, Denis</creator><general>Elsevier Ltd</general><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>N95</scope><scope>XI7</scope></search><sort><creationdate>20180420</creationdate><title>Uniaxial behavior of circular ultra-high-performance fiber-reinforced concrete columns confined by spiral reinforcement</title><author>Shin, Hyun-Oh ; Min, Kyung-Hwan ; Mitchell, Denis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c463t-7b5fc82838b4ce9d93ef4ac3f70632f21140001e37a40406d3c25c6f48b9bc553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Circular column</topic><topic>Ductile behavior</topic><topic>Fiber reinforced concrete</topic><topic>Properties</topic><topic>Spiral reinforcement</topic><topic>Ultra-high-performance fiber-reinforced concrete</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shin, Hyun-Oh</creatorcontrib><creatorcontrib>Min, Kyung-Hwan</creatorcontrib><creatorcontrib>Mitchell, Denis</creatorcontrib><collection>CrossRef</collection><collection>Gale Business Insights</collection><collection>Business Insights: Essentials</collection><jtitle>Construction &amp; building materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shin, Hyun-Oh</au><au>Min, Kyung-Hwan</au><au>Mitchell, Denis</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Uniaxial behavior of circular ultra-high-performance fiber-reinforced concrete columns confined by spiral reinforcement</atitle><jtitle>Construction &amp; building materials</jtitle><date>2018-04-20</date><risdate>2018</risdate><volume>168</volume><spage>379</spage><epage>393</epage><pages>379-393</pages><issn>0950-0618</issn><eissn>1879-0526</eissn><abstract>•Circular UHPFRC columns with varying spiral spacing and concrete strength were tested.•Circular UHPFRC columns detailed with different code provisions were investigated.•The efficiency of circular spirals and square hoops on confinement were compared.•Steel fibers in UHPFRC allowed for gradual spalling and high damage tolerance.•A design recommendation for spiral reinforcement in UHPFRC columns is proposed. This paper presents results from the uniaxial tests of six large-scale ultra-high-performance fiber-reinforced concrete (UHPFRC) circular columns confined by spirals. The UHPFRC used in this study had 1.5% of hybrid micro-steel fibers (1.0% of 19.5 mm fibers and 0.5% of 16.3 mm fibers) in the mixture and had compressive strengths varying from 163 to 181 MPa. The effects of the volumetric ratio of spiral reinforcement, compressive strength of concrete, and presence of hybrid micro-steel fibers on the axial load responses, including post-peak deformability, were investigated. In addition, the ductility level reached by circular UHPFRC columns designed according to the minimum spiral reinforcement of current design provisions of the CSA A23.3-14 Standard and the ACI 318-14 Code were evaluated to investigate the applicability of these equations to UHPFRC columns. Test results showed that the combined effect of the minimum spiral reinforcement and steel fibers resulted in sufficient post-peak ductility of the UHPFRC columns. To investigate the efficiency of the shape of the confinement reinforcement, the test results of the circular UHPFRC columns confined by spirals were compared with those from equivalent-sized square UHPFRC columns confined by hoops. The test results demonstrate the superior performance of circular spirals for developing the ductile behavior of UHPFRC columns than the same volumetric ratio of rectilinear hoops. A design recommendation for spiral reinforcement that ensures the ductile behavior of UHPFRC columns in moderate seismic regions is proposed.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.conbuildmat.2018.02.073</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0950-0618
ispartof Construction & building materials, 2018-04, Vol.168, p.379-393
issn 0950-0618
1879-0526
language eng
recordid cdi_gale_infotracmisc_A538858541
source Elsevier
subjects Circular column
Ductile behavior
Fiber reinforced concrete
Properties
Spiral reinforcement
Ultra-high-performance fiber-reinforced concrete
title Uniaxial behavior of circular ultra-high-performance fiber-reinforced concrete columns confined by spiral reinforcement
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T15%3A55%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Uniaxial%20behavior%20of%20circular%20ultra-high-performance%20fiber-reinforced%20concrete%20columns%20confined%20by%20spiral%20reinforcement&rft.jtitle=Construction%20&%20building%20materials&rft.au=Shin,%20Hyun-Oh&rft.date=2018-04-20&rft.volume=168&rft.spage=379&rft.epage=393&rft.pages=379-393&rft.issn=0950-0618&rft.eissn=1879-0526&rft_id=info:doi/10.1016/j.conbuildmat.2018.02.073&rft_dat=%3Cgale_cross%3EA538858541%3C/gale_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c463t-7b5fc82838b4ce9d93ef4ac3f70632f21140001e37a40406d3c25c6f48b9bc553%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A538858541&rfr_iscdi=true