Device for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilation/Dispositivo para simulacion de patologias restrictivas en sujetos sanos ventilados mecanicamente de manera no invasiva

The respiratory mechanics assessment in patients with mechanical ventilation allows to adjust the treatment in intensive care units related to the ventilatory mode and parameters of mechanical ventilator settings. However, to estimate the compliance and respiratory resistance in spontaneous ventilat...

Full description

Saved in:
Bibliographic Details
Published in:Revista Facultad de Ingeniería 2018-03 (86), p.19
Main Authors: Munoz-Ortega, Isabel Cristina, Urrego-Higuita, David Alexander, Vallejo-Aristizabal, Andres Felipe, Valdivieso, Alher Mauricio Hernandez
Format: Article
Language:Spanish
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 86
container_start_page 19
container_title Revista Facultad de Ingeniería
container_volume
creator Munoz-Ortega, Isabel Cristina
Urrego-Higuita, David Alexander
Vallejo-Aristizabal, Andres Felipe
Valdivieso, Alher Mauricio Hernandez
description The respiratory mechanics assessment in patients with mechanical ventilation allows to adjust the treatment in intensive care units related to the ventilatory mode and parameters of mechanical ventilator settings. However, to estimate the compliance and respiratory resistance in spontaneous ventilation is only possible with obstructive maneuvers or invasive techniques. One of the most important limitations to develop new techniques for respiratory mechanics estimation is the non-stationary characteristic of the system and the variability of parameters according to the variability of the breathing pattern. The aim of this article is to present and evaluate a device that allows artificially modify the thoracic compliance of a healthy subject, which will make possible to register in the future a useful database for the development of techniques for estimating ventilatory mechanics. The device was formed by a cuirass, a pump and a controller that allows to vary the pressure inside the cuirass, which was placed in the chest and abdomen of the volunteers to change compliance in a controlled manner. 5 volunteers participated in the performance test of the device, achieving percentage changes of 34.5 [+ or -] 9.4% respecting their resting value for a pressure of 10 cm[H.sub.2]O and changes of 46.8 [+ or -] 5.7% for the maximum pressure of 20 cm[H.sub.2]O. It was possible to design a device that allowed to artificially modify thoracic compliance in a comparable way for any healthy subject.
format article
fullrecord <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A541641932</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A541641932</galeid><sourcerecordid>A541641932</sourcerecordid><originalsourceid>FETCH-gale_infotracmisc_A5416419323</originalsourceid><addsrcrecordid>eNqNjktOw0AMQLMAifK5gyXWEZOkjcoSURAHYF-ZqdM4mthVPA3ivhyESciCJRv_ZL_ni2zlitLldVm5q-zarHNus63ddpV972hkT9DoAMb9OWBkFdAGBrI4sI88Epwwthr0yGTAAi1hiO0X2PmjIx8NPjm2ICo5y4g2XfTkWxT2GGAkifzLfdixndQ4QTVBB1ycfnIeZs-sQfujTw1JcnUU1cBQUlyYh1Qm0yzq04gmSI9CiSwKyzd4m102GIzulnyT3b--vD-_5UcMtGdpNA7oeza_f9qsi3pdPFZl9b-tH4xzeAM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Device for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilation/Dispositivo para simulacion de patologias restrictivas en sujetos sanos ventilados mecanicamente de manera no invasiva</title><source>Publicly Available Content (ProQuest)</source><creator>Munoz-Ortega, Isabel Cristina ; Urrego-Higuita, David Alexander ; Vallejo-Aristizabal, Andres Felipe ; Valdivieso, Alher Mauricio Hernandez</creator><creatorcontrib>Munoz-Ortega, Isabel Cristina ; Urrego-Higuita, David Alexander ; Vallejo-Aristizabal, Andres Felipe ; Valdivieso, Alher Mauricio Hernandez</creatorcontrib><description>The respiratory mechanics assessment in patients with mechanical ventilation allows to adjust the treatment in intensive care units related to the ventilatory mode and parameters of mechanical ventilator settings. However, to estimate the compliance and respiratory resistance in spontaneous ventilation is only possible with obstructive maneuvers or invasive techniques. One of the most important limitations to develop new techniques for respiratory mechanics estimation is the non-stationary characteristic of the system and the variability of parameters according to the variability of the breathing pattern. The aim of this article is to present and evaluate a device that allows artificially modify the thoracic compliance of a healthy subject, which will make possible to register in the future a useful database for the development of techniques for estimating ventilatory mechanics. The device was formed by a cuirass, a pump and a controller that allows to vary the pressure inside the cuirass, which was placed in the chest and abdomen of the volunteers to change compliance in a controlled manner. 5 volunteers participated in the performance test of the device, achieving percentage changes of 34.5 [+ or -] 9.4% respecting their resting value for a pressure of 10 cm[H.sub.2]O and changes of 46.8 [+ or -] 5.7% for the maximum pressure of 20 cm[H.sub.2]O. It was possible to design a device that allowed to artificially modify thoracic compliance in a comparable way for any healthy subject.</description><identifier>ISSN: 0120-6230</identifier><language>spa</language><publisher>Universidad de Antioquia, Facultad de Ingenieria</publisher><subject>Control systems</subject><ispartof>Revista Facultad de Ingeniería, 2018-03 (86), p.19</ispartof><rights>COPYRIGHT 2018 Universidad de Antioquia, Facultad de Ingenieria</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Munoz-Ortega, Isabel Cristina</creatorcontrib><creatorcontrib>Urrego-Higuita, David Alexander</creatorcontrib><creatorcontrib>Vallejo-Aristizabal, Andres Felipe</creatorcontrib><creatorcontrib>Valdivieso, Alher Mauricio Hernandez</creatorcontrib><title>Device for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilation/Dispositivo para simulacion de patologias restrictivas en sujetos sanos ventilados mecanicamente de manera no invasiva</title><title>Revista Facultad de Ingeniería</title><description>The respiratory mechanics assessment in patients with mechanical ventilation allows to adjust the treatment in intensive care units related to the ventilatory mode and parameters of mechanical ventilator settings. However, to estimate the compliance and respiratory resistance in spontaneous ventilation is only possible with obstructive maneuvers or invasive techniques. One of the most important limitations to develop new techniques for respiratory mechanics estimation is the non-stationary characteristic of the system and the variability of parameters according to the variability of the breathing pattern. The aim of this article is to present and evaluate a device that allows artificially modify the thoracic compliance of a healthy subject, which will make possible to register in the future a useful database for the development of techniques for estimating ventilatory mechanics. The device was formed by a cuirass, a pump and a controller that allows to vary the pressure inside the cuirass, which was placed in the chest and abdomen of the volunteers to change compliance in a controlled manner. 5 volunteers participated in the performance test of the device, achieving percentage changes of 34.5 [+ or -] 9.4% respecting their resting value for a pressure of 10 cm[H.sub.2]O and changes of 46.8 [+ or -] 5.7% for the maximum pressure of 20 cm[H.sub.2]O. It was possible to design a device that allowed to artificially modify thoracic compliance in a comparable way for any healthy subject.</description><subject>Control systems</subject><issn>0120-6230</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNjktOw0AMQLMAifK5gyXWEZOkjcoSURAHYF-ZqdM4mthVPA3ivhyESciCJRv_ZL_ni2zlitLldVm5q-zarHNus63ddpV972hkT9DoAMb9OWBkFdAGBrI4sI88Epwwthr0yGTAAi1hiO0X2PmjIx8NPjm2ICo5y4g2XfTkWxT2GGAkifzLfdixndQ4QTVBB1ycfnIeZs-sQfujTw1JcnUU1cBQUlyYh1Qm0yzq04gmSI9CiSwKyzd4m102GIzulnyT3b--vD-_5UcMtGdpNA7oeza_f9qsi3pdPFZl9b-tH4xzeAM</recordid><startdate>20180301</startdate><enddate>20180301</enddate><creator>Munoz-Ortega, Isabel Cristina</creator><creator>Urrego-Higuita, David Alexander</creator><creator>Vallejo-Aristizabal, Andres Felipe</creator><creator>Valdivieso, Alher Mauricio Hernandez</creator><general>Universidad de Antioquia, Facultad de Ingenieria</general><scope>INF</scope></search><sort><creationdate>20180301</creationdate><title>Device for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilation/Dispositivo para simulacion de patologias restrictivas en sujetos sanos ventilados mecanicamente de manera no invasiva</title><author>Munoz-Ortega, Isabel Cristina ; Urrego-Higuita, David Alexander ; Vallejo-Aristizabal, Andres Felipe ; Valdivieso, Alher Mauricio Hernandez</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-gale_infotracmisc_A5416419323</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>spa</language><creationdate>2018</creationdate><topic>Control systems</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Munoz-Ortega, Isabel Cristina</creatorcontrib><creatorcontrib>Urrego-Higuita, David Alexander</creatorcontrib><creatorcontrib>Vallejo-Aristizabal, Andres Felipe</creatorcontrib><creatorcontrib>Valdivieso, Alher Mauricio Hernandez</creatorcontrib><collection>¡Informe!</collection><jtitle>Revista Facultad de Ingeniería</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Munoz-Ortega, Isabel Cristina</au><au>Urrego-Higuita, David Alexander</au><au>Vallejo-Aristizabal, Andres Felipe</au><au>Valdivieso, Alher Mauricio Hernandez</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Device for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilation/Dispositivo para simulacion de patologias restrictivas en sujetos sanos ventilados mecanicamente de manera no invasiva</atitle><jtitle>Revista Facultad de Ingeniería</jtitle><date>2018-03-01</date><risdate>2018</risdate><issue>86</issue><spage>19</spage><pages>19-</pages><issn>0120-6230</issn><abstract>The respiratory mechanics assessment in patients with mechanical ventilation allows to adjust the treatment in intensive care units related to the ventilatory mode and parameters of mechanical ventilator settings. However, to estimate the compliance and respiratory resistance in spontaneous ventilation is only possible with obstructive maneuvers or invasive techniques. One of the most important limitations to develop new techniques for respiratory mechanics estimation is the non-stationary characteristic of the system and the variability of parameters according to the variability of the breathing pattern. The aim of this article is to present and evaluate a device that allows artificially modify the thoracic compliance of a healthy subject, which will make possible to register in the future a useful database for the development of techniques for estimating ventilatory mechanics. The device was formed by a cuirass, a pump and a controller that allows to vary the pressure inside the cuirass, which was placed in the chest and abdomen of the volunteers to change compliance in a controlled manner. 5 volunteers participated in the performance test of the device, achieving percentage changes of 34.5 [+ or -] 9.4% respecting their resting value for a pressure of 10 cm[H.sub.2]O and changes of 46.8 [+ or -] 5.7% for the maximum pressure of 20 cm[H.sub.2]O. It was possible to design a device that allowed to artificially modify thoracic compliance in a comparable way for any healthy subject.</abstract><pub>Universidad de Antioquia, Facultad de Ingenieria</pub></addata></record>
fulltext fulltext
identifier ISSN: 0120-6230
ispartof Revista Facultad de Ingeniería, 2018-03 (86), p.19
issn 0120-6230
language spa
recordid cdi_gale_infotracmisc_A541641932
source Publicly Available Content (ProQuest)
subjects Control systems
title Device for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilation/Dispositivo para simulacion de patologias restrictivas en sujetos sanos ventilados mecanicamente de manera no invasiva
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T00%3A43%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Device%20for%20simulation%20of%20restrictive%20pathologies%20in%20healthy%20subjects%20with%20non-invasive%20mechanical%20ventilation/Dispositivo%20para%20simulacion%20de%20patologias%20restrictivas%20en%20sujetos%20sanos%20ventilados%20mecanicamente%20de%20manera%20no%20invasiva&rft.jtitle=Revista%20Facultad%20de%20Ingenier%C3%ADa&rft.au=Munoz-Ortega,%20Isabel%20Cristina&rft.date=2018-03-01&rft.issue=86&rft.spage=19&rft.pages=19-&rft.issn=0120-6230&rft_id=info:doi/&rft_dat=%3Cgale%3EA541641932%3C/gale%3E%3Cgrp_id%3Ecdi_FETCH-gale_infotracmisc_A5416419323%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A541641932&rfr_iscdi=true