Loading…

Comparison of voiding cystourethrography and urosonography with second-generation contrast agents in simultaneous prospective study/Porownanie cystouretrografii mikcyjnej i sonocystografii mikcyjnej z uzyciem ultrasonograficznego srodka kontrastujacego drugiej generacji w badaniu prospektywnym

Background: The invasiveness and exposure to radiation in voiding cystourethrography led to the introduction of alternative methods of diagnosis of vesicoureteral reflux, including contrast enhanced voiding urosonography. While there is a limited number of studies comparing these methods using new g...

Full description

Saved in:
Bibliographic Details
Published in:Journal of ultrasonography 2016-12, Vol.16 (67), p.339
Main Authors: Piskunowicz, Maciej, Swieton, Dominik, Rybczynska, Dorota, Czarniak, Piotr, Szarmach, Arkadiusz, Kaszubowski, Mariusz, Szurowska, Edyta
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 67
container_start_page 339
container_title Journal of ultrasonography
container_volume 16
creator Piskunowicz, Maciej
Swieton, Dominik
Rybczynska, Dorota
Czarniak, Piotr
Szarmach, Arkadiusz
Kaszubowski, Mariusz
Szurowska, Edyta
description Background: The invasiveness and exposure to radiation in voiding cystourethrography led to the introduction of alternative methods of diagnosis of vesicoureteral reflux, including contrast enhanced voiding urosonography. While there is a limited number of studies comparing these methods using new generation ultrasound contrast agents, none of them compared both methods simultaneously. This study is aimed at assessing agreement between contrast enhanced voiding urosonography with second-generation ultrasound contrast agents and voiding cystourethrography. Methods: From April 2013 to May 2014, 83 children (37 female and 46 male), mean age 3.5 years, age range from 1 month to 17.5 years, underwent prospective simultaneous assessment by contrast enhanced voiding urosonography and voiding cystourethrography, with a total of 166 uretero-renal units evaluated. Results: The sensitivity of voiding cystourethrography and contrast enhanced voiding urosonography were comparable, amounting to 88%, however, neither reached 100% for the entire studied population. The negative predictive value of voiding urosonography and voiding cystoureth-rography was 97%, and there was no difference between both methods. Conclusion: Voiding cystourethrography and contrast enhanced voiding urosonography are comparable methods in diagnosis of vesicoureteral reflux, and can be performed alternatively. However, some limitations of contrast enhanced voiding urosonography must be remembered. Key words vesicoureteral reflux, voiding cystourethrography, voiding urosonography, ultrasound contrast agent, SonoVue Wprowadzenie: Negatywne skutki promieniowania jonizujacego wykorzystywanego do badan cystouretrografii mikcyjnej wymuszaja poszukiwanie alternatywnych metod diagnostycznych. Takim badaniem moze byc sonocystografia mikcyjna z uzyciem ultrasonograficznych srodków kontrastujacych. Liczba prac porównujacych klasyczne badanie cystouretrografii mikcyjnej i badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej generacji jest jednak niewielka. Dotad nie opublikowano pracy, która porównalaby jednoczasowo obie metody w diagnostyce odplywów pecherzowo-moczowodowych. Prezentowana praca ma na celu ocene zgodnosci miedzy badaniem ultrasonograficznym z uzyciem srodków kontrastujacych drugiej generacji i badaniem cystouretrografii mikcyjnej. Material i metody: W okresie od kwietnia 2013 do maja 2014 roku jednoczasowe badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej ge
doi_str_mv 10.15557/JoU.2016.0034
format article
fullrecord <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A544512688</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A544512688</galeid><sourcerecordid>A544512688</sourcerecordid><originalsourceid>FETCH-LOGICAL-g678-5f5c31d3ad2b395c8bdabbc4f4ba0587e11b0e5d76293813b58c62440ec4bf2b3</originalsourceid><addsrcrecordid>eNptkEtrGzEUhSfQQkOSbdcXAt2No5mRxsoymD4JpIt0HfQc37FHMnrEjH99lNilhRYthM4995wPVdXHhiwaxtjy5of_tWhJ0y8I6ei76rwlnNacEvqhuopxJKTMGO3b9vzs08pPOxEwegfewrNHjW4ANcfkczBpHfwQxG49g3AacvDF-FvZY1pDNMo7XQ_GmSASlpjyTkHEBKKIKQI6iDjlbRLO-BxhV0J2RiV8NhBT1vPNTx_83gmH5k_xW69FhAk3ah6dGQHhtfzN8c_sAPkwKzQTlKLSfqS0qA7ODB5i8HojYHNCy6NQr7IOecCyfaRXI8IepNCFJJ8wN2neu3m6rN5bsY3m6nRfVI9fPj-uvtX3D1-_r-7u66Ff8ppZprpGd0K3srtlikstpFTUUikI40vTNJIYppd9e9vxppOMq76llBhFpS07F9X1MXYQW_OEzvqCqyaM6umOUcqatue8uBb_cZWjzYTl943Fov-18AKZeLT4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Comparison of voiding cystourethrography and urosonography with second-generation contrast agents in simultaneous prospective study/Porownanie cystouretrografii mikcyjnej i sonocystografii mikcyjnej z uzyciem ultrasonograficznego srodka kontrastujacego drugiej generacji w badaniu prospektywnym</title><source>PubMed (Medline)</source><source>IngentaConnect Journals</source><creator>Piskunowicz, Maciej ; Swieton, Dominik ; Rybczynska, Dorota ; Czarniak, Piotr ; Szarmach, Arkadiusz ; Kaszubowski, Mariusz ; Szurowska, Edyta</creator><creatorcontrib>Piskunowicz, Maciej ; Swieton, Dominik ; Rybczynska, Dorota ; Czarniak, Piotr ; Szarmach, Arkadiusz ; Kaszubowski, Mariusz ; Szurowska, Edyta</creatorcontrib><description>Background: The invasiveness and exposure to radiation in voiding cystourethrography led to the introduction of alternative methods of diagnosis of vesicoureteral reflux, including contrast enhanced voiding urosonography. While there is a limited number of studies comparing these methods using new generation ultrasound contrast agents, none of them compared both methods simultaneously. This study is aimed at assessing agreement between contrast enhanced voiding urosonography with second-generation ultrasound contrast agents and voiding cystourethrography. Methods: From April 2013 to May 2014, 83 children (37 female and 46 male), mean age 3.5 years, age range from 1 month to 17.5 years, underwent prospective simultaneous assessment by contrast enhanced voiding urosonography and voiding cystourethrography, with a total of 166 uretero-renal units evaluated. Results: The sensitivity of voiding cystourethrography and contrast enhanced voiding urosonography were comparable, amounting to 88%, however, neither reached 100% for the entire studied population. The negative predictive value of voiding urosonography and voiding cystoureth-rography was 97%, and there was no difference between both methods. Conclusion: Voiding cystourethrography and contrast enhanced voiding urosonography are comparable methods in diagnosis of vesicoureteral reflux, and can be performed alternatively. However, some limitations of contrast enhanced voiding urosonography must be remembered. Key words vesicoureteral reflux, voiding cystourethrography, voiding urosonography, ultrasound contrast agent, SonoVue Wprowadzenie: Negatywne skutki promieniowania jonizujacego wykorzystywanego do badan cystouretrografii mikcyjnej wymuszaja poszukiwanie alternatywnych metod diagnostycznych. Takim badaniem moze byc sonocystografia mikcyjna z uzyciem ultrasonograficznych srodków kontrastujacych. Liczba prac porównujacych klasyczne badanie cystouretrografii mikcyjnej i badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej generacji jest jednak niewielka. Dotad nie opublikowano pracy, która porównalaby jednoczasowo obie metody w diagnostyce odplywów pecherzowo-moczowodowych. Prezentowana praca ma na celu ocene zgodnosci miedzy badaniem ultrasonograficznym z uzyciem srodków kontrastujacych drugiej generacji i badaniem cystouretrografii mikcyjnej. Material i metody: W okresie od kwietnia 2013 do maja 2014 roku jednoczasowe badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej generacji i cystouretrografii mikcyjnej wykonano u 83 dzieci (37 dziewczynek i 46 chlopców, srednia wieku 3,5 roku, zakres wieku od 1 miesiaca do 17,5 roku). Prospektywnej ocenie zostalo poddanych 166 jednostek moczowodowo-nerkowych. Wyniki: W badaniu wykazano podobna czulosc obu metod diagnostycznych w diagnostyce odplywów pecherzowo-moczowodowych, na poziomie 88%, zadna z metod nie osiagnela wyniku 100%. Ujemna wartosc predykcyjna dla obu metod wyniosla 97% i nie wykazano zadnej istotnej róznicy pomiedzy obiema metodami w zakresie diagnostyki odplywów pecherzowo-moczowodowych. Wniosek: Obie metody wykazaly podobna czulosc w ocenie odplywów pecherzowo-moczowodowych. Nalezy jednak pamietac o mozliwych ograniczeniach badania ultrasonograficznego z uzyciem srodków kontrastujacych drugiej generacji w diagnostyce fazy mikcyjnej u niespokojnych, placzacych w trakcie badania dzieci. Slowa kluczowe odplyw pecherzowo-moczowodowy, sonocystografia mikcyjna, ultrasonograficzne srodki kontrastujace, SonoVue</description><identifier>ISSN: 2084-8404</identifier><identifier>DOI: 10.15557/JoU.2016.0034</identifier><language>eng</language><publisher>Exeley Inc</publisher><subject>Comparative analysis ; Contrast media ; Ionizing radiation</subject><ispartof>Journal of ultrasonography, 2016-12, Vol.16 (67), p.339</ispartof><rights>COPYRIGHT 2016 Exeley Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Piskunowicz, Maciej</creatorcontrib><creatorcontrib>Swieton, Dominik</creatorcontrib><creatorcontrib>Rybczynska, Dorota</creatorcontrib><creatorcontrib>Czarniak, Piotr</creatorcontrib><creatorcontrib>Szarmach, Arkadiusz</creatorcontrib><creatorcontrib>Kaszubowski, Mariusz</creatorcontrib><creatorcontrib>Szurowska, Edyta</creatorcontrib><title>Comparison of voiding cystourethrography and urosonography with second-generation contrast agents in simultaneous prospective study/Porownanie cystouretrografii mikcyjnej i sonocystografii mikcyjnej z uzyciem ultrasonograficznego srodka kontrastujacego drugiej generacji w badaniu prospektywnym</title><title>Journal of ultrasonography</title><description>Background: The invasiveness and exposure to radiation in voiding cystourethrography led to the introduction of alternative methods of diagnosis of vesicoureteral reflux, including contrast enhanced voiding urosonography. While there is a limited number of studies comparing these methods using new generation ultrasound contrast agents, none of them compared both methods simultaneously. This study is aimed at assessing agreement between contrast enhanced voiding urosonography with second-generation ultrasound contrast agents and voiding cystourethrography. Methods: From April 2013 to May 2014, 83 children (37 female and 46 male), mean age 3.5 years, age range from 1 month to 17.5 years, underwent prospective simultaneous assessment by contrast enhanced voiding urosonography and voiding cystourethrography, with a total of 166 uretero-renal units evaluated. Results: The sensitivity of voiding cystourethrography and contrast enhanced voiding urosonography were comparable, amounting to 88%, however, neither reached 100% for the entire studied population. The negative predictive value of voiding urosonography and voiding cystoureth-rography was 97%, and there was no difference between both methods. Conclusion: Voiding cystourethrography and contrast enhanced voiding urosonography are comparable methods in diagnosis of vesicoureteral reflux, and can be performed alternatively. However, some limitations of contrast enhanced voiding urosonography must be remembered. Key words vesicoureteral reflux, voiding cystourethrography, voiding urosonography, ultrasound contrast agent, SonoVue Wprowadzenie: Negatywne skutki promieniowania jonizujacego wykorzystywanego do badan cystouretrografii mikcyjnej wymuszaja poszukiwanie alternatywnych metod diagnostycznych. Takim badaniem moze byc sonocystografia mikcyjna z uzyciem ultrasonograficznych srodków kontrastujacych. Liczba prac porównujacych klasyczne badanie cystouretrografii mikcyjnej i badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej generacji jest jednak niewielka. Dotad nie opublikowano pracy, która porównalaby jednoczasowo obie metody w diagnostyce odplywów pecherzowo-moczowodowych. Prezentowana praca ma na celu ocene zgodnosci miedzy badaniem ultrasonograficznym z uzyciem srodków kontrastujacych drugiej generacji i badaniem cystouretrografii mikcyjnej. Material i metody: W okresie od kwietnia 2013 do maja 2014 roku jednoczasowe badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej generacji i cystouretrografii mikcyjnej wykonano u 83 dzieci (37 dziewczynek i 46 chlopców, srednia wieku 3,5 roku, zakres wieku od 1 miesiaca do 17,5 roku). Prospektywnej ocenie zostalo poddanych 166 jednostek moczowodowo-nerkowych. Wyniki: W badaniu wykazano podobna czulosc obu metod diagnostycznych w diagnostyce odplywów pecherzowo-moczowodowych, na poziomie 88%, zadna z metod nie osiagnela wyniku 100%. Ujemna wartosc predykcyjna dla obu metod wyniosla 97% i nie wykazano zadnej istotnej róznicy pomiedzy obiema metodami w zakresie diagnostyki odplywów pecherzowo-moczowodowych. Wniosek: Obie metody wykazaly podobna czulosc w ocenie odplywów pecherzowo-moczowodowych. Nalezy jednak pamietac o mozliwych ograniczeniach badania ultrasonograficznego z uzyciem srodków kontrastujacych drugiej generacji w diagnostyce fazy mikcyjnej u niespokojnych, placzacych w trakcie badania dzieci. Slowa kluczowe odplyw pecherzowo-moczowodowy, sonocystografia mikcyjna, ultrasonograficzne srodki kontrastujace, SonoVue</description><subject>Comparative analysis</subject><subject>Contrast media</subject><subject>Ionizing radiation</subject><issn>2084-8404</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNptkEtrGzEUhSfQQkOSbdcXAt2No5mRxsoymD4JpIt0HfQc37FHMnrEjH99lNilhRYthM4995wPVdXHhiwaxtjy5of_tWhJ0y8I6ei76rwlnNacEvqhuopxJKTMGO3b9vzs08pPOxEwegfewrNHjW4ANcfkczBpHfwQxG49g3AacvDF-FvZY1pDNMo7XQ_GmSASlpjyTkHEBKKIKQI6iDjlbRLO-BxhV0J2RiV8NhBT1vPNTx_83gmH5k_xW69FhAk3ah6dGQHhtfzN8c_sAPkwKzQTlKLSfqS0qA7ODB5i8HojYHNCy6NQr7IOecCyfaRXI8IepNCFJJ8wN2neu3m6rN5bsY3m6nRfVI9fPj-uvtX3D1-_r-7u66Ff8ppZprpGd0K3srtlikstpFTUUikI40vTNJIYppd9e9vxppOMq76llBhFpS07F9X1MXYQW_OEzvqCqyaM6umOUcqatue8uBb_cZWjzYTl943Fov-18AKZeLT4</recordid><startdate>20161201</startdate><enddate>20161201</enddate><creator>Piskunowicz, Maciej</creator><creator>Swieton, Dominik</creator><creator>Rybczynska, Dorota</creator><creator>Czarniak, Piotr</creator><creator>Szarmach, Arkadiusz</creator><creator>Kaszubowski, Mariusz</creator><creator>Szurowska, Edyta</creator><general>Exeley Inc</general><scope/></search><sort><creationdate>20161201</creationdate><title>Comparison of voiding cystourethrography and urosonography with second-generation contrast agents in simultaneous prospective study/Porownanie cystouretrografii mikcyjnej i sonocystografii mikcyjnej z uzyciem ultrasonograficznego srodka kontrastujacego drugiej generacji w badaniu prospektywnym</title><author>Piskunowicz, Maciej ; Swieton, Dominik ; Rybczynska, Dorota ; Czarniak, Piotr ; Szarmach, Arkadiusz ; Kaszubowski, Mariusz ; Szurowska, Edyta</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g678-5f5c31d3ad2b395c8bdabbc4f4ba0587e11b0e5d76293813b58c62440ec4bf2b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Comparative analysis</topic><topic>Contrast media</topic><topic>Ionizing radiation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Piskunowicz, Maciej</creatorcontrib><creatorcontrib>Swieton, Dominik</creatorcontrib><creatorcontrib>Rybczynska, Dorota</creatorcontrib><creatorcontrib>Czarniak, Piotr</creatorcontrib><creatorcontrib>Szarmach, Arkadiusz</creatorcontrib><creatorcontrib>Kaszubowski, Mariusz</creatorcontrib><creatorcontrib>Szurowska, Edyta</creatorcontrib><jtitle>Journal of ultrasonography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Piskunowicz, Maciej</au><au>Swieton, Dominik</au><au>Rybczynska, Dorota</au><au>Czarniak, Piotr</au><au>Szarmach, Arkadiusz</au><au>Kaszubowski, Mariusz</au><au>Szurowska, Edyta</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of voiding cystourethrography and urosonography with second-generation contrast agents in simultaneous prospective study/Porownanie cystouretrografii mikcyjnej i sonocystografii mikcyjnej z uzyciem ultrasonograficznego srodka kontrastujacego drugiej generacji w badaniu prospektywnym</atitle><jtitle>Journal of ultrasonography</jtitle><date>2016-12-01</date><risdate>2016</risdate><volume>16</volume><issue>67</issue><spage>339</spage><pages>339-</pages><issn>2084-8404</issn><abstract>Background: The invasiveness and exposure to radiation in voiding cystourethrography led to the introduction of alternative methods of diagnosis of vesicoureteral reflux, including contrast enhanced voiding urosonography. While there is a limited number of studies comparing these methods using new generation ultrasound contrast agents, none of them compared both methods simultaneously. This study is aimed at assessing agreement between contrast enhanced voiding urosonography with second-generation ultrasound contrast agents and voiding cystourethrography. Methods: From April 2013 to May 2014, 83 children (37 female and 46 male), mean age 3.5 years, age range from 1 month to 17.5 years, underwent prospective simultaneous assessment by contrast enhanced voiding urosonography and voiding cystourethrography, with a total of 166 uretero-renal units evaluated. Results: The sensitivity of voiding cystourethrography and contrast enhanced voiding urosonography were comparable, amounting to 88%, however, neither reached 100% for the entire studied population. The negative predictive value of voiding urosonography and voiding cystoureth-rography was 97%, and there was no difference between both methods. Conclusion: Voiding cystourethrography and contrast enhanced voiding urosonography are comparable methods in diagnosis of vesicoureteral reflux, and can be performed alternatively. However, some limitations of contrast enhanced voiding urosonography must be remembered. Key words vesicoureteral reflux, voiding cystourethrography, voiding urosonography, ultrasound contrast agent, SonoVue Wprowadzenie: Negatywne skutki promieniowania jonizujacego wykorzystywanego do badan cystouretrografii mikcyjnej wymuszaja poszukiwanie alternatywnych metod diagnostycznych. Takim badaniem moze byc sonocystografia mikcyjna z uzyciem ultrasonograficznych srodków kontrastujacych. Liczba prac porównujacych klasyczne badanie cystouretrografii mikcyjnej i badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej generacji jest jednak niewielka. Dotad nie opublikowano pracy, która porównalaby jednoczasowo obie metody w diagnostyce odplywów pecherzowo-moczowodowych. Prezentowana praca ma na celu ocene zgodnosci miedzy badaniem ultrasonograficznym z uzyciem srodków kontrastujacych drugiej generacji i badaniem cystouretrografii mikcyjnej. Material i metody: W okresie od kwietnia 2013 do maja 2014 roku jednoczasowe badanie ultrasonograficzne z uzyciem srodków kontrastujacych drugiej generacji i cystouretrografii mikcyjnej wykonano u 83 dzieci (37 dziewczynek i 46 chlopców, srednia wieku 3,5 roku, zakres wieku od 1 miesiaca do 17,5 roku). Prospektywnej ocenie zostalo poddanych 166 jednostek moczowodowo-nerkowych. Wyniki: W badaniu wykazano podobna czulosc obu metod diagnostycznych w diagnostyce odplywów pecherzowo-moczowodowych, na poziomie 88%, zadna z metod nie osiagnela wyniku 100%. Ujemna wartosc predykcyjna dla obu metod wyniosla 97% i nie wykazano zadnej istotnej róznicy pomiedzy obiema metodami w zakresie diagnostyki odplywów pecherzowo-moczowodowych. Wniosek: Obie metody wykazaly podobna czulosc w ocenie odplywów pecherzowo-moczowodowych. Nalezy jednak pamietac o mozliwych ograniczeniach badania ultrasonograficznego z uzyciem srodków kontrastujacych drugiej generacji w diagnostyce fazy mikcyjnej u niespokojnych, placzacych w trakcie badania dzieci. Slowa kluczowe odplyw pecherzowo-moczowodowy, sonocystografia mikcyjna, ultrasonograficzne srodki kontrastujace, SonoVue</abstract><pub>Exeley Inc</pub><doi>10.15557/JoU.2016.0034</doi></addata></record>
fulltext fulltext
identifier ISSN: 2084-8404
ispartof Journal of ultrasonography, 2016-12, Vol.16 (67), p.339
issn 2084-8404
language eng
recordid cdi_gale_infotracmisc_A544512688
source PubMed (Medline); IngentaConnect Journals
subjects Comparative analysis
Contrast media
Ionizing radiation
title Comparison of voiding cystourethrography and urosonography with second-generation contrast agents in simultaneous prospective study/Porownanie cystouretrografii mikcyjnej i sonocystografii mikcyjnej z uzyciem ultrasonograficznego srodka kontrastujacego drugiej generacji w badaniu prospektywnym
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T23%3A08%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20voiding%20cystourethrography%20and%20urosonography%20with%20second-generation%20contrast%20agents%20in%20simultaneous%20prospective%20study/Porownanie%20cystouretrografii%20mikcyjnej%20i%20sonocystografii%20mikcyjnej%20z%20uzyciem%20ultrasonograficznego%20srodka%20kontrastujacego%20drugiej%20generacji%20w%20badaniu%20prospektywnym&rft.jtitle=Journal%20of%20ultrasonography&rft.au=Piskunowicz,%20Maciej&rft.date=2016-12-01&rft.volume=16&rft.issue=67&rft.spage=339&rft.pages=339-&rft.issn=2084-8404&rft_id=info:doi/10.15557/JoU.2016.0034&rft_dat=%3Cgale%3EA544512688%3C/gale%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-g678-5f5c31d3ad2b395c8bdabbc4f4ba0587e11b0e5d76293813b58c62440ec4bf2b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A544512688&rfr_iscdi=true