Loading…
Dual-Axis Hanle Magnetometer Based on Atomic Alignment with a Single Optical Access
The usual Hanle-effect magnetometers allow the measurement of two components of a very-low magnetic field using three orthogonal light beams. Here we present a scheme based on atomic alignment that requires only a single optical access for both a pump beam and a probe beam with a small angle between...
Saved in:
Published in: | Physical review applied 2019-12, Vol.12 (6), Article 064010 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c343t-dc3546e5bfd778b0c5fefaf03e0b899c3e35c8f7c587f86044508aa6c31c4d1b3 |
---|---|
cites | cdi_FETCH-LOGICAL-c343t-dc3546e5bfd778b0c5fefaf03e0b899c3e35c8f7c587f86044508aa6c31c4d1b3 |
container_end_page | |
container_issue | 6 |
container_start_page | |
container_title | Physical review applied |
container_volume | 12 |
creator | Le Gal, Gwenael Lieb, Gaëtan Beato, François Jager, Thomas Gilles, Hervé Palacios-Laloy, Agustin |
description | The usual Hanle-effect magnetometers allow the measurement of two components of a very-low magnetic field using three orthogonal light beams. Here we present a scheme based on atomic alignment that requires only a single optical access for both a pump beam and a probe beam with a small angle between them. The results of experimental tests of this configuration are in close agreement with the theoretical predictions. We show that measurements of the third component should be possible by instrumentation of a partial depolarization of the pump beam. Such compact architectures open interesting perspectives for magnetometer arrays for medical imaging. |
doi_str_mv | 10.1103/PhysRevApplied.12.064010 |
format | article |
fullrecord | <record><control><sourceid>hal_cross</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_cea_03141284v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_HAL_cea_03141284v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-c343t-dc3546e5bfd778b0c5fefaf03e0b899c3e35c8f7c587f86044508aa6c31c4d1b3</originalsourceid><addsrcrecordid>eNpVkM1OwzAQhC0EElXpO_jKIWU3dhL3GMpPkYqKKJwtx1m3RmkSxaHQtyeoCMFpR6uZ0ehjjCNMEUFcPW0P4Zn2edtWnsopxlNIJSCcsFEsBEYZ4Oz0jz5nkxDeAAAxTkDBiK1v3k0V5Z8-8IWpK-KPZlNT3-yop45fm0Alb2qeDx9veV75Tb2juucfvt9yw9e-3gyhVdt7ayqeW0shXLAzZ6pAk587Zq93ty_zRbRc3T_M82VkhRR9VFqRyJSSwpVZpgqwiSNnHAiCQs1mVpBIrHKZTVTmVApSDpONSa1AK0ssxJhdHnu3ptJt53emO-jGeL3Il9qS0SBQYqzkHgevOnpt14TQkfsNIOhvlvo_S42xPrIUX_4Eaww</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Dual-Axis Hanle Magnetometer Based on Atomic Alignment with a Single Optical Access</title><source>American Physical Society:Jisc Collections:APS Read and Publish 2023-2025 (reading list)</source><creator>Le Gal, Gwenael ; Lieb, Gaëtan ; Beato, François ; Jager, Thomas ; Gilles, Hervé ; Palacios-Laloy, Agustin</creator><creatorcontrib>Le Gal, Gwenael ; Lieb, Gaëtan ; Beato, François ; Jager, Thomas ; Gilles, Hervé ; Palacios-Laloy, Agustin</creatorcontrib><description>The usual Hanle-effect magnetometers allow the measurement of two components of a very-low magnetic field using three orthogonal light beams. Here we present a scheme based on atomic alignment that requires only a single optical access for both a pump beam and a probe beam with a small angle between them. The results of experimental tests of this configuration are in close agreement with the theoretical predictions. We show that measurements of the third component should be possible by instrumentation of a partial depolarization of the pump beam. Such compact architectures open interesting perspectives for magnetometer arrays for medical imaging.</description><identifier>ISSN: 2331-7019</identifier><identifier>EISSN: 2331-7019</identifier><identifier>DOI: 10.1103/PhysRevApplied.12.064010</identifier><language>eng</language><publisher>American Physical Society</publisher><subject>Physics</subject><ispartof>Physical review applied, 2019-12, Vol.12 (6), Article 064010</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c343t-dc3546e5bfd778b0c5fefaf03e0b899c3e35c8f7c587f86044508aa6c31c4d1b3</citedby><cites>FETCH-LOGICAL-c343t-dc3546e5bfd778b0c5fefaf03e0b899c3e35c8f7c587f86044508aa6c31c4d1b3</cites><orcidid>0000-0001-7312-3317 ; 0000-0001-9871-9934</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27903,27904</link.rule.ids><backlink>$$Uhttps://cea.hal.science/cea-03141284$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Le Gal, Gwenael</creatorcontrib><creatorcontrib>Lieb, Gaëtan</creatorcontrib><creatorcontrib>Beato, François</creatorcontrib><creatorcontrib>Jager, Thomas</creatorcontrib><creatorcontrib>Gilles, Hervé</creatorcontrib><creatorcontrib>Palacios-Laloy, Agustin</creatorcontrib><title>Dual-Axis Hanle Magnetometer Based on Atomic Alignment with a Single Optical Access</title><title>Physical review applied</title><description>The usual Hanle-effect magnetometers allow the measurement of two components of a very-low magnetic field using three orthogonal light beams. Here we present a scheme based on atomic alignment that requires only a single optical access for both a pump beam and a probe beam with a small angle between them. The results of experimental tests of this configuration are in close agreement with the theoretical predictions. We show that measurements of the third component should be possible by instrumentation of a partial depolarization of the pump beam. Such compact architectures open interesting perspectives for magnetometer arrays for medical imaging.</description><subject>Physics</subject><issn>2331-7019</issn><issn>2331-7019</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpVkM1OwzAQhC0EElXpO_jKIWU3dhL3GMpPkYqKKJwtx1m3RmkSxaHQtyeoCMFpR6uZ0ehjjCNMEUFcPW0P4Zn2edtWnsopxlNIJSCcsFEsBEYZ4Oz0jz5nkxDeAAAxTkDBiK1v3k0V5Z8-8IWpK-KPZlNT3-yop45fm0Alb2qeDx9veV75Tb2juucfvt9yw9e-3gyhVdt7ayqeW0shXLAzZ6pAk587Zq93ty_zRbRc3T_M82VkhRR9VFqRyJSSwpVZpgqwiSNnHAiCQs1mVpBIrHKZTVTmVApSDpONSa1AK0ssxJhdHnu3ptJt53emO-jGeL3Il9qS0SBQYqzkHgevOnpt14TQkfsNIOhvlvo_S42xPrIUX_4Eaww</recordid><startdate>20191204</startdate><enddate>20191204</enddate><creator>Le Gal, Gwenael</creator><creator>Lieb, Gaëtan</creator><creator>Beato, François</creator><creator>Jager, Thomas</creator><creator>Gilles, Hervé</creator><creator>Palacios-Laloy, Agustin</creator><general>American Physical Society</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0001-7312-3317</orcidid><orcidid>https://orcid.org/0000-0001-9871-9934</orcidid></search><sort><creationdate>20191204</creationdate><title>Dual-Axis Hanle Magnetometer Based on Atomic Alignment with a Single Optical Access</title><author>Le Gal, Gwenael ; Lieb, Gaëtan ; Beato, François ; Jager, Thomas ; Gilles, Hervé ; Palacios-Laloy, Agustin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c343t-dc3546e5bfd778b0c5fefaf03e0b899c3e35c8f7c587f86044508aa6c31c4d1b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Le Gal, Gwenael</creatorcontrib><creatorcontrib>Lieb, Gaëtan</creatorcontrib><creatorcontrib>Beato, François</creatorcontrib><creatorcontrib>Jager, Thomas</creatorcontrib><creatorcontrib>Gilles, Hervé</creatorcontrib><creatorcontrib>Palacios-Laloy, Agustin</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Physical review applied</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Le Gal, Gwenael</au><au>Lieb, Gaëtan</au><au>Beato, François</au><au>Jager, Thomas</au><au>Gilles, Hervé</au><au>Palacios-Laloy, Agustin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dual-Axis Hanle Magnetometer Based on Atomic Alignment with a Single Optical Access</atitle><jtitle>Physical review applied</jtitle><date>2019-12-04</date><risdate>2019</risdate><volume>12</volume><issue>6</issue><artnum>064010</artnum><issn>2331-7019</issn><eissn>2331-7019</eissn><abstract>The usual Hanle-effect magnetometers allow the measurement of two components of a very-low magnetic field using three orthogonal light beams. Here we present a scheme based on atomic alignment that requires only a single optical access for both a pump beam and a probe beam with a small angle between them. The results of experimental tests of this configuration are in close agreement with the theoretical predictions. We show that measurements of the third component should be possible by instrumentation of a partial depolarization of the pump beam. Such compact architectures open interesting perspectives for magnetometer arrays for medical imaging.</abstract><pub>American Physical Society</pub><doi>10.1103/PhysRevApplied.12.064010</doi><orcidid>https://orcid.org/0000-0001-7312-3317</orcidid><orcidid>https://orcid.org/0000-0001-9871-9934</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2331-7019 |
ispartof | Physical review applied, 2019-12, Vol.12 (6), Article 064010 |
issn | 2331-7019 2331-7019 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_cea_03141284v1 |
source | American Physical Society:Jisc Collections:APS Read and Publish 2023-2025 (reading list) |
subjects | Physics |
title | Dual-Axis Hanle Magnetometer Based on Atomic Alignment with a Single Optical Access |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T15%3A40%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dual-Axis%20Hanle%20Magnetometer%20Based%20on%20Atomic%20Alignment%20with%20a%20Single%20Optical%20Access&rft.jtitle=Physical%20review%20applied&rft.au=Le%20Gal,%20Gwenael&rft.date=2019-12-04&rft.volume=12&rft.issue=6&rft.artnum=064010&rft.issn=2331-7019&rft.eissn=2331-7019&rft_id=info:doi/10.1103/PhysRevApplied.12.064010&rft_dat=%3Chal_cross%3Eoai_HAL_cea_03141284v1%3C/hal_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c343t-dc3546e5bfd778b0c5fefaf03e0b899c3e35c8f7c587f86044508aa6c31c4d1b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |