Loading…

Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER

Shutdown dose rate (SDDR) calculations have been performed to give support to the design of the Interspace (IS) VIS/IR WAVS diagnostic components of the Equatorial Port 12 (EP12), in the framework of the F4E-FPA-407 SG04 project. The Vis/IR WAVS comprises the viewing systems in four Equatorial Ports...

Full description

Saved in:
Bibliographic Details
Published in:Fusion engineering and design 2021-11, Vol.172, p.112916, Article 112916
Main Authors: Mota, F., Peneliau, Y., Catalan, J.P., Alguacil, J., Medrano, M., Rincón, E., Cabrera, S., Carrasco, R., Lapayese, F., Pastor, C., de la Peña, A., Pereira, A., Queral, V., Ramos, F., Rodríguez, C., Soleto, A., Letellier, L., Le Guern, F., Piqueras, J.J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c377t-ea0e387b86eaa5c9bc0cbe77a29f13408fef7494eaab55d3e1139635c2f9e0013
cites cdi_FETCH-LOGICAL-c377t-ea0e387b86eaa5c9bc0cbe77a29f13408fef7494eaab55d3e1139635c2f9e0013
container_end_page
container_issue
container_start_page 112916
container_title Fusion engineering and design
container_volume 172
creator Mota, F.
Peneliau, Y.
Catalan, J.P.
Alguacil, J.
Medrano, M.
Rincón, E.
Cabrera, S.
Carrasco, R.
Lapayese, F.
Pastor, C.
de la Peña, A.
Pereira, A.
Queral, V.
Ramos, F.
Rodríguez, C.
Soleto, A.
Letellier, L.
Le Guern, F.
Piqueras, J.J.
description Shutdown dose rate (SDDR) calculations have been performed to give support to the design of the Interspace (IS) VIS/IR WAVS diagnostic components of the Equatorial Port 12 (EP12), in the framework of the F4E-FPA-407 SG04 project. The Vis/IR WAVS comprises the viewing systems in four Equatorial Ports: 3, 9, 12 and 17, reminding that the present results are relative to the EP12 specifically. The Vis/IR WAVS is an optical diagnostic aimed at monitoring in visible and infrared radiation the ITER plasma facing components for machine protection. This paper describes the methodology used and shows the results obtained. The objective of the assessment is to evaluate whether the design meets the ALARA criteria in the IS area. In this work, once the materials have been selected to contribute as less as possible to the activation, the main criterion is that the contribution of all diagnostics installed in the port should not overcome the target of the biological dose rate of 100 μSv/h in the IS area after 106s of decay time. The main conclusion of the analysis is that the contribution of the VIS/IR WAVS IS components to the SDDR meets with the ALARA criterion in the IS. The contribution of the VIS/IR WAVS IS components to the SDDR in the IS, concerning the contribution of the whole ITER model, is about 9.6% in the left corridor and 5.5% in the right corridor. Besides, the percentage of contribution of the SS316L structure with respect to the total SDDR induced by the IS VIS/IR WAVS components is 99.3% in the left corridor and 99.5% in the right corridor. However, it has to be taken into account that these values have been obtained using a local model, therefore these values will be lower than the realistic values. Therefore, these values should be taken only as relative values.
doi_str_mv 10.1016/j.fusengdes.2021.112916
format article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_cea_04844729v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S092037962100692X</els_id><sourcerecordid>2619670609</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-ea0e387b86eaa5c9bc0cbe77a29f13408fef7494eaab55d3e1139635c2f9e0013</originalsourceid><addsrcrecordid>eNqFkUFrGzEQhUVoIY7T31BBTz2sI63Wq9XRhKQ2GAKJexaydmTLtSVXI8f431dmQ66FgTm8bx4z8wj5ztmEM94-7CbuhBA2PeCkZjWfcF4r3t6QEe-kqCRX7RcyYqpmlZCqvSV3iDvGuCw1In_etqfcx3OgfUSgyWSgBhEQDxAyjY7mLVAfMiQ8GgvUxsMxhqLhVTz7vvBhswf67uHsw4biBTMcaO_NJkTM3lIXE12snl7vyVdn9gjfPvqY_H5-Wj3Oq-XLr8XjbFlZIWWuwDAQnVx3LRgztWptmV2DlKZWjouGdQ6cbFRT1PV02gvgXKhWTG3tFJTDxJj8HHy3Zq-PyR9MuuhovJ7PltqC0azpmkbW6v3K_hjYY4p_T4BZ7-IphbKertvyOslapgolB8qmiJjAfdpypq8p6J3-TEFfU9BDCmVyNkxCObi8KGm0HoKF3iewWffR_9fjH1DYla4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2619670609</pqid></control><display><type>article</type><title>Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER</title><source>Elsevier</source><creator>Mota, F. ; Peneliau, Y. ; Catalan, J.P. ; Alguacil, J. ; Medrano, M. ; Rincón, E. ; Cabrera, S. ; Carrasco, R. ; Lapayese, F. ; Pastor, C. ; de la Peña, A. ; Pereira, A. ; Queral, V. ; Ramos, F. ; Rodríguez, C. ; Soleto, A. ; Letellier, L. ; Le Guern, F. ; Piqueras, J.J.</creator><creatorcontrib>Mota, F. ; Peneliau, Y. ; Catalan, J.P. ; Alguacil, J. ; Medrano, M. ; Rincón, E. ; Cabrera, S. ; Carrasco, R. ; Lapayese, F. ; Pastor, C. ; de la Peña, A. ; Pereira, A. ; Queral, V. ; Ramos, F. ; Rodríguez, C. ; Soleto, A. ; Letellier, L. ; Le Guern, F. ; Piqueras, J.J.</creatorcontrib><description>Shutdown dose rate (SDDR) calculations have been performed to give support to the design of the Interspace (IS) VIS/IR WAVS diagnostic components of the Equatorial Port 12 (EP12), in the framework of the F4E-FPA-407 SG04 project. The Vis/IR WAVS comprises the viewing systems in four Equatorial Ports: 3, 9, 12 and 17, reminding that the present results are relative to the EP12 specifically. The Vis/IR WAVS is an optical diagnostic aimed at monitoring in visible and infrared radiation the ITER plasma facing components for machine protection. This paper describes the methodology used and shows the results obtained. The objective of the assessment is to evaluate whether the design meets the ALARA criteria in the IS area. In this work, once the materials have been selected to contribute as less as possible to the activation, the main criterion is that the contribution of all diagnostics installed in the port should not overcome the target of the biological dose rate of 100 μSv/h in the IS area after 106s of decay time. The main conclusion of the analysis is that the contribution of the VIS/IR WAVS IS components to the SDDR meets with the ALARA criterion in the IS. The contribution of the VIS/IR WAVS IS components to the SDDR in the IS, concerning the contribution of the whole ITER model, is about 9.6% in the left corridor and 5.5% in the right corridor. Besides, the percentage of contribution of the SS316L structure with respect to the total SDDR induced by the IS VIS/IR WAVS components is 99.3% in the left corridor and 99.5% in the right corridor. However, it has to be taken into account that these values have been obtained using a local model, therefore these values will be lower than the realistic values. Therefore, these values should be taken only as relative values.</description><identifier>ISSN: 0920-3796</identifier><identifier>EISSN: 1873-7196</identifier><identifier>DOI: 10.1016/j.fusengdes.2021.112916</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Criteria ; D1SUNED ; Diagnostic ; Diagnostic systems ; Dosage ; Engineering Sciences ; Infrared radiation ; ITER ; Materials selection ; Nuclear analysis ; Physics ; Shutdowns ; Viewing ; WAVS</subject><ispartof>Fusion engineering and design, 2021-11, Vol.172, p.112916, Article 112916</ispartof><rights>2021 Elsevier B.V.</rights><rights>Copyright Elsevier Science Ltd. Nov 2021</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-ea0e387b86eaa5c9bc0cbe77a29f13408fef7494eaab55d3e1139635c2f9e0013</citedby><cites>FETCH-LOGICAL-c377t-ea0e387b86eaa5c9bc0cbe77a29f13408fef7494eaab55d3e1139635c2f9e0013</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://cea.hal.science/cea-04844729$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Mota, F.</creatorcontrib><creatorcontrib>Peneliau, Y.</creatorcontrib><creatorcontrib>Catalan, J.P.</creatorcontrib><creatorcontrib>Alguacil, J.</creatorcontrib><creatorcontrib>Medrano, M.</creatorcontrib><creatorcontrib>Rincón, E.</creatorcontrib><creatorcontrib>Cabrera, S.</creatorcontrib><creatorcontrib>Carrasco, R.</creatorcontrib><creatorcontrib>Lapayese, F.</creatorcontrib><creatorcontrib>Pastor, C.</creatorcontrib><creatorcontrib>de la Peña, A.</creatorcontrib><creatorcontrib>Pereira, A.</creatorcontrib><creatorcontrib>Queral, V.</creatorcontrib><creatorcontrib>Ramos, F.</creatorcontrib><creatorcontrib>Rodríguez, C.</creatorcontrib><creatorcontrib>Soleto, A.</creatorcontrib><creatorcontrib>Letellier, L.</creatorcontrib><creatorcontrib>Le Guern, F.</creatorcontrib><creatorcontrib>Piqueras, J.J.</creatorcontrib><title>Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER</title><title>Fusion engineering and design</title><description>Shutdown dose rate (SDDR) calculations have been performed to give support to the design of the Interspace (IS) VIS/IR WAVS diagnostic components of the Equatorial Port 12 (EP12), in the framework of the F4E-FPA-407 SG04 project. The Vis/IR WAVS comprises the viewing systems in four Equatorial Ports: 3, 9, 12 and 17, reminding that the present results are relative to the EP12 specifically. The Vis/IR WAVS is an optical diagnostic aimed at monitoring in visible and infrared radiation the ITER plasma facing components for machine protection. This paper describes the methodology used and shows the results obtained. The objective of the assessment is to evaluate whether the design meets the ALARA criteria in the IS area. In this work, once the materials have been selected to contribute as less as possible to the activation, the main criterion is that the contribution of all diagnostics installed in the port should not overcome the target of the biological dose rate of 100 μSv/h in the IS area after 106s of decay time. The main conclusion of the analysis is that the contribution of the VIS/IR WAVS IS components to the SDDR meets with the ALARA criterion in the IS. The contribution of the VIS/IR WAVS IS components to the SDDR in the IS, concerning the contribution of the whole ITER model, is about 9.6% in the left corridor and 5.5% in the right corridor. Besides, the percentage of contribution of the SS316L structure with respect to the total SDDR induced by the IS VIS/IR WAVS components is 99.3% in the left corridor and 99.5% in the right corridor. However, it has to be taken into account that these values have been obtained using a local model, therefore these values will be lower than the realistic values. Therefore, these values should be taken only as relative values.</description><subject>Criteria</subject><subject>D1SUNED</subject><subject>Diagnostic</subject><subject>Diagnostic systems</subject><subject>Dosage</subject><subject>Engineering Sciences</subject><subject>Infrared radiation</subject><subject>ITER</subject><subject>Materials selection</subject><subject>Nuclear analysis</subject><subject>Physics</subject><subject>Shutdowns</subject><subject>Viewing</subject><subject>WAVS</subject><issn>0920-3796</issn><issn>1873-7196</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqFkUFrGzEQhUVoIY7T31BBTz2sI63Wq9XRhKQ2GAKJexaydmTLtSVXI8f431dmQ66FgTm8bx4z8wj5ztmEM94-7CbuhBA2PeCkZjWfcF4r3t6QEe-kqCRX7RcyYqpmlZCqvSV3iDvGuCw1In_etqfcx3OgfUSgyWSgBhEQDxAyjY7mLVAfMiQ8GgvUxsMxhqLhVTz7vvBhswf67uHsw4biBTMcaO_NJkTM3lIXE12snl7vyVdn9gjfPvqY_H5-Wj3Oq-XLr8XjbFlZIWWuwDAQnVx3LRgztWptmV2DlKZWjouGdQ6cbFRT1PV02gvgXKhWTG3tFJTDxJj8HHy3Zq-PyR9MuuhovJ7PltqC0azpmkbW6v3K_hjYY4p_T4BZ7-IphbKertvyOslapgolB8qmiJjAfdpypq8p6J3-TEFfU9BDCmVyNkxCObi8KGm0HoKF3iewWffR_9fjH1DYla4</recordid><startdate>202111</startdate><enddate>202111</enddate><creator>Mota, F.</creator><creator>Peneliau, Y.</creator><creator>Catalan, J.P.</creator><creator>Alguacil, J.</creator><creator>Medrano, M.</creator><creator>Rincón, E.</creator><creator>Cabrera, S.</creator><creator>Carrasco, R.</creator><creator>Lapayese, F.</creator><creator>Pastor, C.</creator><creator>de la Peña, A.</creator><creator>Pereira, A.</creator><creator>Queral, V.</creator><creator>Ramos, F.</creator><creator>Rodríguez, C.</creator><creator>Soleto, A.</creator><creator>Letellier, L.</creator><creator>Le Guern, F.</creator><creator>Piqueras, J.J.</creator><general>Elsevier B.V</general><general>Elsevier Science Ltd</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope><scope>1XC</scope></search><sort><creationdate>202111</creationdate><title>Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER</title><author>Mota, F. ; Peneliau, Y. ; Catalan, J.P. ; Alguacil, J. ; Medrano, M. ; Rincón, E. ; Cabrera, S. ; Carrasco, R. ; Lapayese, F. ; Pastor, C. ; de la Peña, A. ; Pereira, A. ; Queral, V. ; Ramos, F. ; Rodríguez, C. ; Soleto, A. ; Letellier, L. ; Le Guern, F. ; Piqueras, J.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-ea0e387b86eaa5c9bc0cbe77a29f13408fef7494eaab55d3e1139635c2f9e0013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Criteria</topic><topic>D1SUNED</topic><topic>Diagnostic</topic><topic>Diagnostic systems</topic><topic>Dosage</topic><topic>Engineering Sciences</topic><topic>Infrared radiation</topic><topic>ITER</topic><topic>Materials selection</topic><topic>Nuclear analysis</topic><topic>Physics</topic><topic>Shutdowns</topic><topic>Viewing</topic><topic>WAVS</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mota, F.</creatorcontrib><creatorcontrib>Peneliau, Y.</creatorcontrib><creatorcontrib>Catalan, J.P.</creatorcontrib><creatorcontrib>Alguacil, J.</creatorcontrib><creatorcontrib>Medrano, M.</creatorcontrib><creatorcontrib>Rincón, E.</creatorcontrib><creatorcontrib>Cabrera, S.</creatorcontrib><creatorcontrib>Carrasco, R.</creatorcontrib><creatorcontrib>Lapayese, F.</creatorcontrib><creatorcontrib>Pastor, C.</creatorcontrib><creatorcontrib>de la Peña, A.</creatorcontrib><creatorcontrib>Pereira, A.</creatorcontrib><creatorcontrib>Queral, V.</creatorcontrib><creatorcontrib>Ramos, F.</creatorcontrib><creatorcontrib>Rodríguez, C.</creatorcontrib><creatorcontrib>Soleto, A.</creatorcontrib><creatorcontrib>Letellier, L.</creatorcontrib><creatorcontrib>Le Guern, F.</creatorcontrib><creatorcontrib>Piqueras, J.J.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Fusion engineering and design</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mota, F.</au><au>Peneliau, Y.</au><au>Catalan, J.P.</au><au>Alguacil, J.</au><au>Medrano, M.</au><au>Rincón, E.</au><au>Cabrera, S.</au><au>Carrasco, R.</au><au>Lapayese, F.</au><au>Pastor, C.</au><au>de la Peña, A.</au><au>Pereira, A.</au><au>Queral, V.</au><au>Ramos, F.</au><au>Rodríguez, C.</au><au>Soleto, A.</au><au>Letellier, L.</au><au>Le Guern, F.</au><au>Piqueras, J.J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER</atitle><jtitle>Fusion engineering and design</jtitle><date>2021-11</date><risdate>2021</risdate><volume>172</volume><spage>112916</spage><pages>112916-</pages><artnum>112916</artnum><issn>0920-3796</issn><eissn>1873-7196</eissn><abstract>Shutdown dose rate (SDDR) calculations have been performed to give support to the design of the Interspace (IS) VIS/IR WAVS diagnostic components of the Equatorial Port 12 (EP12), in the framework of the F4E-FPA-407 SG04 project. The Vis/IR WAVS comprises the viewing systems in four Equatorial Ports: 3, 9, 12 and 17, reminding that the present results are relative to the EP12 specifically. The Vis/IR WAVS is an optical diagnostic aimed at monitoring in visible and infrared radiation the ITER plasma facing components for machine protection. This paper describes the methodology used and shows the results obtained. The objective of the assessment is to evaluate whether the design meets the ALARA criteria in the IS area. In this work, once the materials have been selected to contribute as less as possible to the activation, the main criterion is that the contribution of all diagnostics installed in the port should not overcome the target of the biological dose rate of 100 μSv/h in the IS area after 106s of decay time. The main conclusion of the analysis is that the contribution of the VIS/IR WAVS IS components to the SDDR meets with the ALARA criterion in the IS. The contribution of the VIS/IR WAVS IS components to the SDDR in the IS, concerning the contribution of the whole ITER model, is about 9.6% in the left corridor and 5.5% in the right corridor. Besides, the percentage of contribution of the SS316L structure with respect to the total SDDR induced by the IS VIS/IR WAVS components is 99.3% in the left corridor and 99.5% in the right corridor. However, it has to be taken into account that these values have been obtained using a local model, therefore these values will be lower than the realistic values. Therefore, these values should be taken only as relative values.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.fusengdes.2021.112916</doi></addata></record>
fulltext fulltext
identifier ISSN: 0920-3796
ispartof Fusion engineering and design, 2021-11, Vol.172, p.112916, Article 112916
issn 0920-3796
1873-7196
language eng
recordid cdi_hal_primary_oai_HAL_cea_04844729v1
source Elsevier
subjects Criteria
D1SUNED
Diagnostic
Diagnostic systems
Dosage
Engineering Sciences
Infrared radiation
ITER
Materials selection
Nuclear analysis
Physics
Shutdowns
Viewing
WAVS
title Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T23%3A51%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Shutdown%20dose%20rate%20assessment%20of%20the%20interspace%20components%20of%20wide%20angle%20viewing%20system%20diagnostic%20for%20ITER&rft.jtitle=Fusion%20engineering%20and%20design&rft.au=Mota,%20F.&rft.date=2021-11&rft.volume=172&rft.spage=112916&rft.pages=112916-&rft.artnum=112916&rft.issn=0920-3796&rft.eissn=1873-7196&rft_id=info:doi/10.1016/j.fusengdes.2021.112916&rft_dat=%3Cproquest_hal_p%3E2619670609%3C/proquest_hal_p%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c377t-ea0e387b86eaa5c9bc0cbe77a29f13408fef7494eaab55d3e1139635c2f9e0013%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2619670609&rft_id=info:pmid/&rfr_iscdi=true