Loading…
High frequency CV measurements of SiC MOS capacitors
MOS capacitors have been fabricated on a p-type 6H–SiC substrate with 〈0001〉Si orientation. The oxide was thermally grown under wet conditions. High frequency CV measurements have been carried out with different sweep rates and stress times in darkness and under different illumination conditions. Th...
Saved in:
Published in: | Solid-state electronics 1998-06, Vol.42 (6), p.915-920 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c372t-695b5fabc77cb9ab7c571b252daf443e6010ea7342878d8a5216f1c6adc232233 |
---|---|
cites | cdi_FETCH-LOGICAL-c372t-695b5fabc77cb9ab7c571b252daf443e6010ea7342878d8a5216f1c6adc232233 |
container_end_page | 920 |
container_issue | 6 |
container_start_page | 915 |
container_title | Solid-state electronics |
container_volume | 42 |
creator | Berberich, S Godignon, P Locatelli, M.L Millán, J Hartnagel, H.L |
description | MOS capacitors have been fabricated on a p-type 6H–SiC substrate with 〈0001〉Si orientation. The oxide was thermally grown under wet conditions. High frequency
CV measurements have been carried out with different sweep rates and stress times in darkness and under different illumination conditions. The bump which appears in the
CV curves is most likely a 6H–SiC manifestation of nonequilibrium effects. A hook which occurs in deep depletion when the structure is measured with UV light is observed. The density of states has been determined using the Terman method and the conductance technique including band bending fluctuations. Due to nonequilibrium effects in the semiconductor occurring during
CV measurements, the Terman method induces errors in the extraction of the interface trap density of SiC MOS devices. The low value of the standard deviation of the surface potential was assumed to be rather due to the large interface state density than to an improvement of the SiC/SiO
2 interface. The extracted
D
it values at the SiC/SiO
2 interface are in the range of 10
12
cm
−2
eV
−1, similar to those available in literature for this oxidation temperature. |
doi_str_mv | 10.1016/S0038-1101(98)00122-1 |
format | article |
fullrecord | <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_00141584v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0038110198001221</els_id><sourcerecordid>27552337</sourcerecordid><originalsourceid>FETCH-LOGICAL-c372t-695b5fabc77cb9ab7c571b252daf443e6010ea7342878d8a5216f1c6adc232233</originalsourceid><addsrcrecordid>eNqFkEFLwzAUx4MoOKcfQehJ3KGalzZNepIx1AmTHaZeQ5q-uki7zqQb7NubruLVUx7h9_6P_4-Qa6B3QCG7X1GayBjCfJvLCaXAWAwnZARS5DFLKT8loz_knFx4_0UpZRnQEUnn9nMdVQ6_d7gxh2j2ETWo_c5hg5vOR20Vrewsel2uIqO32tiudf6SnFW69nj1-47J-9Pj22weL5bPL7PpIjaJYF2c5bzglS6MEKbIdSEMF1AwzkpdpWmCGQWKWiQpk0KWUnMGWQUm06VhCWNJMiaTIXeta7V1ttHuoFpt1Xy6UP1f6JoCl-keAnszsFvXhi6-U431Butab7DdecUE5yFSBJAPoHGt9w6rv2Sgqvepjj5VL0vlUh19qv7Aw7CHofHeolPe2OAMS-vQdKps7T8JPzHtecM</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27552337</pqid></control><display><type>article</type><title>High frequency CV measurements of SiC MOS capacitors</title><source>ScienceDirect Journals</source><creator>Berberich, S ; Godignon, P ; Locatelli, M.L ; Millán, J ; Hartnagel, H.L</creator><creatorcontrib>Berberich, S ; Godignon, P ; Locatelli, M.L ; Millán, J ; Hartnagel, H.L</creatorcontrib><description>MOS capacitors have been fabricated on a p-type 6H–SiC substrate with 〈0001〉Si orientation. The oxide was thermally grown under wet conditions. High frequency
CV measurements have been carried out with different sweep rates and stress times in darkness and under different illumination conditions. The bump which appears in the
CV curves is most likely a 6H–SiC manifestation of nonequilibrium effects. A hook which occurs in deep depletion when the structure is measured with UV light is observed. The density of states has been determined using the Terman method and the conductance technique including band bending fluctuations. Due to nonequilibrium effects in the semiconductor occurring during
CV measurements, the Terman method induces errors in the extraction of the interface trap density of SiC MOS devices. The low value of the standard deviation of the surface potential was assumed to be rather due to the large interface state density than to an improvement of the SiC/SiO
2 interface. The extracted
D
it values at the SiC/SiO
2 interface are in the range of 10
12
cm
−2
eV
−1, similar to those available in literature for this oxidation temperature.</description><identifier>ISSN: 0038-1101</identifier><identifier>EISSN: 1879-2405</identifier><identifier>DOI: 10.1016/S0038-1101(98)00122-1</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Electric power ; Engineering Sciences</subject><ispartof>Solid-state electronics, 1998-06, Vol.42 (6), p.915-920</ispartof><rights>1998 Elsevier Science Ltd</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c372t-695b5fabc77cb9ab7c571b252daf443e6010ea7342878d8a5216f1c6adc232233</citedby><cites>FETCH-LOGICAL-c372t-695b5fabc77cb9ab7c571b252daf443e6010ea7342878d8a5216f1c6adc232233</cites><orcidid>0000-0001-5981-8649</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://hal.science/hal-00141584$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Berberich, S</creatorcontrib><creatorcontrib>Godignon, P</creatorcontrib><creatorcontrib>Locatelli, M.L</creatorcontrib><creatorcontrib>Millán, J</creatorcontrib><creatorcontrib>Hartnagel, H.L</creatorcontrib><title>High frequency CV measurements of SiC MOS capacitors</title><title>Solid-state electronics</title><description>MOS capacitors have been fabricated on a p-type 6H–SiC substrate with 〈0001〉Si orientation. The oxide was thermally grown under wet conditions. High frequency
CV measurements have been carried out with different sweep rates and stress times in darkness and under different illumination conditions. The bump which appears in the
CV curves is most likely a 6H–SiC manifestation of nonequilibrium effects. A hook which occurs in deep depletion when the structure is measured with UV light is observed. The density of states has been determined using the Terman method and the conductance technique including band bending fluctuations. Due to nonequilibrium effects in the semiconductor occurring during
CV measurements, the Terman method induces errors in the extraction of the interface trap density of SiC MOS devices. The low value of the standard deviation of the surface potential was assumed to be rather due to the large interface state density than to an improvement of the SiC/SiO
2 interface. The extracted
D
it values at the SiC/SiO
2 interface are in the range of 10
12
cm
−2
eV
−1, similar to those available in literature for this oxidation temperature.</description><subject>Electric power</subject><subject>Engineering Sciences</subject><issn>0038-1101</issn><issn>1879-2405</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkEFLwzAUx4MoOKcfQehJ3KGalzZNepIx1AmTHaZeQ5q-uki7zqQb7NubruLVUx7h9_6P_4-Qa6B3QCG7X1GayBjCfJvLCaXAWAwnZARS5DFLKT8loz_knFx4_0UpZRnQEUnn9nMdVQ6_d7gxh2j2ETWo_c5hg5vOR20Vrewsel2uIqO32tiudf6SnFW69nj1-47J-9Pj22weL5bPL7PpIjaJYF2c5bzglS6MEKbIdSEMF1AwzkpdpWmCGQWKWiQpk0KWUnMGWQUm06VhCWNJMiaTIXeta7V1ttHuoFpt1Xy6UP1f6JoCl-keAnszsFvXhi6-U431Butab7DdecUE5yFSBJAPoHGt9w6rv2Sgqvepjj5VL0vlUh19qv7Aw7CHofHeolPe2OAMS-vQdKps7T8JPzHtecM</recordid><startdate>19980601</startdate><enddate>19980601</enddate><creator>Berberich, S</creator><creator>Godignon, P</creator><creator>Locatelli, M.L</creator><creator>Millán, J</creator><creator>Hartnagel, H.L</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>1XC</scope><orcidid>https://orcid.org/0000-0001-5981-8649</orcidid></search><sort><creationdate>19980601</creationdate><title>High frequency CV measurements of SiC MOS capacitors</title><author>Berberich, S ; Godignon, P ; Locatelli, M.L ; Millán, J ; Hartnagel, H.L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c372t-695b5fabc77cb9ab7c571b252daf443e6010ea7342878d8a5216f1c6adc232233</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Electric power</topic><topic>Engineering Sciences</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Berberich, S</creatorcontrib><creatorcontrib>Godignon, P</creatorcontrib><creatorcontrib>Locatelli, M.L</creatorcontrib><creatorcontrib>Millán, J</creatorcontrib><creatorcontrib>Hartnagel, H.L</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Solid-state electronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Berberich, S</au><au>Godignon, P</au><au>Locatelli, M.L</au><au>Millán, J</au><au>Hartnagel, H.L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High frequency CV measurements of SiC MOS capacitors</atitle><jtitle>Solid-state electronics</jtitle><date>1998-06-01</date><risdate>1998</risdate><volume>42</volume><issue>6</issue><spage>915</spage><epage>920</epage><pages>915-920</pages><issn>0038-1101</issn><eissn>1879-2405</eissn><abstract>MOS capacitors have been fabricated on a p-type 6H–SiC substrate with 〈0001〉Si orientation. The oxide was thermally grown under wet conditions. High frequency
CV measurements have been carried out with different sweep rates and stress times in darkness and under different illumination conditions. The bump which appears in the
CV curves is most likely a 6H–SiC manifestation of nonequilibrium effects. A hook which occurs in deep depletion when the structure is measured with UV light is observed. The density of states has been determined using the Terman method and the conductance technique including band bending fluctuations. Due to nonequilibrium effects in the semiconductor occurring during
CV measurements, the Terman method induces errors in the extraction of the interface trap density of SiC MOS devices. The low value of the standard deviation of the surface potential was assumed to be rather due to the large interface state density than to an improvement of the SiC/SiO
2 interface. The extracted
D
it values at the SiC/SiO
2 interface are in the range of 10
12
cm
−2
eV
−1, similar to those available in literature for this oxidation temperature.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/S0038-1101(98)00122-1</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0001-5981-8649</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0038-1101 |
ispartof | Solid-state electronics, 1998-06, Vol.42 (6), p.915-920 |
issn | 0038-1101 1879-2405 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_00141584v1 |
source | ScienceDirect Journals |
subjects | Electric power Engineering Sciences |
title | High frequency CV measurements of SiC MOS capacitors |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T14%3A10%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20frequency%20CV%20measurements%20of%20SiC%20MOS%20capacitors&rft.jtitle=Solid-state%20electronics&rft.au=Berberich,%20S&rft.date=1998-06-01&rft.volume=42&rft.issue=6&rft.spage=915&rft.epage=920&rft.pages=915-920&rft.issn=0038-1101&rft.eissn=1879-2405&rft_id=info:doi/10.1016/S0038-1101(98)00122-1&rft_dat=%3Cproquest_hal_p%3E27552337%3C/proquest_hal_p%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c372t-695b5fabc77cb9ab7c571b252daf443e6010ea7342878d8a5216f1c6adc232233%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=27552337&rft_id=info:pmid/&rfr_iscdi=true |