Loading…
Time resolved flowfield, flame structure and acoustic characterization of a staged multi-injection burner
The present work details the analysis of staging and multipoint injection effects on the flow field, flame structure and acoustic properties of a lean swirled injector, representative of a gas turbine burner. The study is carried out for a constant power and global equivalence ratio while the stagin...
Saved in:
Published in: | Proceedings of the Combustion Institute 2009, Vol.32 (2), p.2965-2972 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c337t-433155fb887666562225ea96c7a3268cfd382cb731d8f7e55fdefcaebb8d124b3 |
---|---|
cites | cdi_FETCH-LOGICAL-c337t-433155fb887666562225ea96c7a3268cfd382cb731d8f7e55fdefcaebb8d124b3 |
container_end_page | 2972 |
container_issue | 2 |
container_start_page | 2965 |
container_title | Proceedings of the Combustion Institute |
container_volume | 32 |
creator | Barbosa, Séverine Scouflaire, Philippe Ducruix, Sébastien |
description | The present work details the analysis of staging and multipoint injection effects on the flow field, flame structure and acoustic properties of a lean swirled injector, representative of a gas turbine burner. The study is carried out for a constant power and global equivalence ratio while the staging parameter
α between pilot and multipoint stages is varied. Using PLIF-OH, it is shown that the flame structure consists in a large central recirculation zone of burnt gases surrounded by an annular conical jet of fresh gases. The OH spatial distribution indicates that increasing
α significantly modifies the flame structure, which becomes more compact and more organized while the mean flame front angle increases. Using High Frequency PIV in the reactive situation, a temporal analysis of the velocity field is carried out, indicating that large coherent structures appear periodically within the combustion chamber. The structure frequencies are determined and compared with acoustic measurements. This comparison indicates that for
α
=
0%, the vortex frequency is slightly lower than the first eigenmode of the chamber, while for
α
=
30%, it corresponds to a secondary peak at a higher frequency of the spectrum for both
p′ and
q′, with dramatic consequences on the burner behavior in terms of stability. When
α increases starting from zero, the level of
p′ and
q′ increases to reach a maximum value for
α
=
20% before decreasing for higher staging. This acoustic behavior can be compared with the evolution of the temperature in the injector, that also reaches a maximum value for
α
=
20%, proving that strong instabilities are associated with flame stabilization within the injector. Increasing the staging factor makes it possible to decrease the flame instability level while keeping the flame compact and robust. |
doi_str_mv | 10.1016/j.proci.2008.06.139 |
format | article |
fullrecord | <record><control><sourceid>hal_cross</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_00497672v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1540748908002563</els_id><sourcerecordid>oai_HAL_hal_00497672v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-433155fb887666562225ea96c7a3268cfd382cb731d8f7e55fdefcaebb8d124b3</originalsourceid><addsrcrecordid>eNp9UE1LwzAYLqLgnP4CL70KtuajTbKDhzHUCQMv8xzS5I1L6ZqRtBP99WabePT0PrzPBzxPlt1iVGKE2UNb7oLXriQIiRKxEtPZWTbBgtOCcFSdJ1xXqOCVmF1mVzG2CFGOaD3J3NptIQ8QfbcHk9vOf1oHnblPUCUmDmHUwxggV73JlfZjHJzO9UYFpQcI7lsNzve5t7lKYvWRQrZjN7jC9S3oI9eMoYdwnV1Y1UW4-b3T7P35ab1YFqu3l9fFfFVoSvlQVJTiuraNEJwxVjNCSA1qxjRXlDChraGC6IZTbITlkKQGrFbQNMJgUjV0mt2dcjeqk7vgtip8Sa-cXM5X8vBDqJpxxskeJy09aXXwMQawfwaM5GFZ2crjsvKwrERMpmWT6_HkglRj7yDIqB30GowLqbI03v3r_wG6NYTO</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Time resolved flowfield, flame structure and acoustic characterization of a staged multi-injection burner</title><source>Elsevier</source><creator>Barbosa, Séverine ; Scouflaire, Philippe ; Ducruix, Sébastien</creator><creatorcontrib>Barbosa, Séverine ; Scouflaire, Philippe ; Ducruix, Sébastien</creatorcontrib><description>The present work details the analysis of staging and multipoint injection effects on the flow field, flame structure and acoustic properties of a lean swirled injector, representative of a gas turbine burner. The study is carried out for a constant power and global equivalence ratio while the staging parameter
α between pilot and multipoint stages is varied. Using PLIF-OH, it is shown that the flame structure consists in a large central recirculation zone of burnt gases surrounded by an annular conical jet of fresh gases. The OH spatial distribution indicates that increasing
α significantly modifies the flame structure, which becomes more compact and more organized while the mean flame front angle increases. Using High Frequency PIV in the reactive situation, a temporal analysis of the velocity field is carried out, indicating that large coherent structures appear periodically within the combustion chamber. The structure frequencies are determined and compared with acoustic measurements. This comparison indicates that for
α
=
0%, the vortex frequency is slightly lower than the first eigenmode of the chamber, while for
α
=
30%, it corresponds to a secondary peak at a higher frequency of the spectrum for both
p′ and
q′, with dramatic consequences on the burner behavior in terms of stability. When
α increases starting from zero, the level of
p′ and
q′ increases to reach a maximum value for
α
=
20% before decreasing for higher staging. This acoustic behavior can be compared with the evolution of the temperature in the injector, that also reaches a maximum value for
α
=
20%, proving that strong instabilities are associated with flame stabilization within the injector. Increasing the staging factor makes it possible to decrease the flame instability level while keeping the flame compact and robust.</description><identifier>ISSN: 1540-7489</identifier><identifier>EISSN: 1873-2704</identifier><identifier>EISSN: 1540-7489</identifier><identifier>DOI: 10.1016/j.proci.2008.06.139</identifier><language>eng</language><publisher>Elsevier Inc</publisher><subject>Acoustic flame interactions ; Engineering Sciences ; Flame dynamics ; Gas turbine ; High frequency PIV ; Multipoint injection ; Reactive fluid environment</subject><ispartof>Proceedings of the Combustion Institute, 2009, Vol.32 (2), p.2965-2972</ispartof><rights>2009 The Combustion Institute</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c337t-433155fb887666562225ea96c7a3268cfd382cb731d8f7e55fdefcaebb8d124b3</citedby><cites>FETCH-LOGICAL-c337t-433155fb887666562225ea96c7a3268cfd382cb731d8f7e55fdefcaebb8d124b3</cites><orcidid>0000-0002-3934-9176 ; 0000-0003-3159-7172 ; 0000-0003-0993-139X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,4010,27902,27903,27904</link.rule.ids><backlink>$$Uhttps://hal.science/hal-00497672$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Barbosa, Séverine</creatorcontrib><creatorcontrib>Scouflaire, Philippe</creatorcontrib><creatorcontrib>Ducruix, Sébastien</creatorcontrib><title>Time resolved flowfield, flame structure and acoustic characterization of a staged multi-injection burner</title><title>Proceedings of the Combustion Institute</title><description>The present work details the analysis of staging and multipoint injection effects on the flow field, flame structure and acoustic properties of a lean swirled injector, representative of a gas turbine burner. The study is carried out for a constant power and global equivalence ratio while the staging parameter
α between pilot and multipoint stages is varied. Using PLIF-OH, it is shown that the flame structure consists in a large central recirculation zone of burnt gases surrounded by an annular conical jet of fresh gases. The OH spatial distribution indicates that increasing
α significantly modifies the flame structure, which becomes more compact and more organized while the mean flame front angle increases. Using High Frequency PIV in the reactive situation, a temporal analysis of the velocity field is carried out, indicating that large coherent structures appear periodically within the combustion chamber. The structure frequencies are determined and compared with acoustic measurements. This comparison indicates that for
α
=
0%, the vortex frequency is slightly lower than the first eigenmode of the chamber, while for
α
=
30%, it corresponds to a secondary peak at a higher frequency of the spectrum for both
p′ and
q′, with dramatic consequences on the burner behavior in terms of stability. When
α increases starting from zero, the level of
p′ and
q′ increases to reach a maximum value for
α
=
20% before decreasing for higher staging. This acoustic behavior can be compared with the evolution of the temperature in the injector, that also reaches a maximum value for
α
=
20%, proving that strong instabilities are associated with flame stabilization within the injector. Increasing the staging factor makes it possible to decrease the flame instability level while keeping the flame compact and robust.</description><subject>Acoustic flame interactions</subject><subject>Engineering Sciences</subject><subject>Flame dynamics</subject><subject>Gas turbine</subject><subject>High frequency PIV</subject><subject>Multipoint injection</subject><subject>Reactive fluid environment</subject><issn>1540-7489</issn><issn>1873-2704</issn><issn>1540-7489</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9UE1LwzAYLqLgnP4CL70KtuajTbKDhzHUCQMv8xzS5I1L6ZqRtBP99WabePT0PrzPBzxPlt1iVGKE2UNb7oLXriQIiRKxEtPZWTbBgtOCcFSdJ1xXqOCVmF1mVzG2CFGOaD3J3NptIQ8QfbcHk9vOf1oHnblPUCUmDmHUwxggV73JlfZjHJzO9UYFpQcI7lsNzve5t7lKYvWRQrZjN7jC9S3oI9eMoYdwnV1Y1UW4-b3T7P35ab1YFqu3l9fFfFVoSvlQVJTiuraNEJwxVjNCSA1qxjRXlDChraGC6IZTbITlkKQGrFbQNMJgUjV0mt2dcjeqk7vgtip8Sa-cXM5X8vBDqJpxxskeJy09aXXwMQawfwaM5GFZ2crjsvKwrERMpmWT6_HkglRj7yDIqB30GowLqbI03v3r_wG6NYTO</recordid><startdate>2009</startdate><enddate>2009</enddate><creator>Barbosa, Séverine</creator><creator>Scouflaire, Philippe</creator><creator>Ducruix, Sébastien</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><orcidid>https://orcid.org/0000-0002-3934-9176</orcidid><orcidid>https://orcid.org/0000-0003-3159-7172</orcidid><orcidid>https://orcid.org/0000-0003-0993-139X</orcidid></search><sort><creationdate>2009</creationdate><title>Time resolved flowfield, flame structure and acoustic characterization of a staged multi-injection burner</title><author>Barbosa, Séverine ; Scouflaire, Philippe ; Ducruix, Sébastien</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-433155fb887666562225ea96c7a3268cfd382cb731d8f7e55fdefcaebb8d124b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Acoustic flame interactions</topic><topic>Engineering Sciences</topic><topic>Flame dynamics</topic><topic>Gas turbine</topic><topic>High frequency PIV</topic><topic>Multipoint injection</topic><topic>Reactive fluid environment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Barbosa, Séverine</creatorcontrib><creatorcontrib>Scouflaire, Philippe</creatorcontrib><creatorcontrib>Ducruix, Sébastien</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Proceedings of the Combustion Institute</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Barbosa, Séverine</au><au>Scouflaire, Philippe</au><au>Ducruix, Sébastien</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Time resolved flowfield, flame structure and acoustic characterization of a staged multi-injection burner</atitle><jtitle>Proceedings of the Combustion Institute</jtitle><date>2009</date><risdate>2009</risdate><volume>32</volume><issue>2</issue><spage>2965</spage><epage>2972</epage><pages>2965-2972</pages><issn>1540-7489</issn><eissn>1873-2704</eissn><eissn>1540-7489</eissn><abstract>The present work details the analysis of staging and multipoint injection effects on the flow field, flame structure and acoustic properties of a lean swirled injector, representative of a gas turbine burner. The study is carried out for a constant power and global equivalence ratio while the staging parameter
α between pilot and multipoint stages is varied. Using PLIF-OH, it is shown that the flame structure consists in a large central recirculation zone of burnt gases surrounded by an annular conical jet of fresh gases. The OH spatial distribution indicates that increasing
α significantly modifies the flame structure, which becomes more compact and more organized while the mean flame front angle increases. Using High Frequency PIV in the reactive situation, a temporal analysis of the velocity field is carried out, indicating that large coherent structures appear periodically within the combustion chamber. The structure frequencies are determined and compared with acoustic measurements. This comparison indicates that for
α
=
0%, the vortex frequency is slightly lower than the first eigenmode of the chamber, while for
α
=
30%, it corresponds to a secondary peak at a higher frequency of the spectrum for both
p′ and
q′, with dramatic consequences on the burner behavior in terms of stability. When
α increases starting from zero, the level of
p′ and
q′ increases to reach a maximum value for
α
=
20% before decreasing for higher staging. This acoustic behavior can be compared with the evolution of the temperature in the injector, that also reaches a maximum value for
α
=
20%, proving that strong instabilities are associated with flame stabilization within the injector. Increasing the staging factor makes it possible to decrease the flame instability level while keeping the flame compact and robust.</abstract><pub>Elsevier Inc</pub><doi>10.1016/j.proci.2008.06.139</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-3934-9176</orcidid><orcidid>https://orcid.org/0000-0003-3159-7172</orcidid><orcidid>https://orcid.org/0000-0003-0993-139X</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1540-7489 |
ispartof | Proceedings of the Combustion Institute, 2009, Vol.32 (2), p.2965-2972 |
issn | 1540-7489 1873-2704 1540-7489 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_00497672v1 |
source | Elsevier |
subjects | Acoustic flame interactions Engineering Sciences Flame dynamics Gas turbine High frequency PIV Multipoint injection Reactive fluid environment |
title | Time resolved flowfield, flame structure and acoustic characterization of a staged multi-injection burner |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T16%3A06%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Time%20resolved%20flowfield,%20flame%20structure%20and%20acoustic%20characterization%20of%20a%20staged%20multi-injection%20burner&rft.jtitle=Proceedings%20of%20the%20Combustion%20Institute&rft.au=Barbosa,%20S%C3%A9verine&rft.date=2009&rft.volume=32&rft.issue=2&rft.spage=2965&rft.epage=2972&rft.pages=2965-2972&rft.issn=1540-7489&rft.eissn=1873-2704&rft_id=info:doi/10.1016/j.proci.2008.06.139&rft_dat=%3Chal_cross%3Eoai_HAL_hal_00497672v1%3C/hal_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c337t-433155fb887666562225ea96c7a3268cfd382cb731d8f7e55fdefcaebb8d124b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |