An important challenge for low energy buildings lies in the need to master airflows through the building envelope. This paper describes a campaign on 21 low-energy houses. First, we carried out an aeraulic measurement campaign on every dwelling including visual survey, airflow or pressure at the air...

Full description

Saved in:
Bibliographic Details
Published in:The International journal of ventilation 2018-07, Vol.17 (3), p.187-195
Main Authors: Guyot, Gaëlle, Melois, Adeline, Bernard, Anne-Marie, Coeudevez, Claire-Sophie, Déoux, Suzanne, Berlin, Sandra, Parent, Enora, Huet, Alexis, Berthault, Sylvain, Jobert, Romuald, Labaume, Damien
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c391t-abaf861bb70a417e70698c4875bea3ac78b46d7198f36884b9aacb8a0c7123c73
cites cdi_FETCH-LOGICAL-c391t-abaf861bb70a417e70698c4875bea3ac78b46d7198f36884b9aacb8a0c7123c73
container_end_page 195
container_issue 3
container_start_page 187
container_title The International journal of ventilation
container_volume 17
creator Guyot, Gaëlle
Melois, Adeline
Bernard, Anne-Marie
Coeudevez, Claire-Sophie
Déoux, Suzanne
Berlin, Sandra
Parent, Enora
Huet, Alexis
Berthault, Sylvain
Jobert, Romuald
Labaume, Damien
description An important challenge for low energy buildings lies in the need to master airflows through the building envelope. This paper describes a campaign on 21 low-energy houses. First, we carried out an aeraulic measurement campaign on every dwelling including visual survey, airflow or pressure at the air-vents, ventilation duct airleakage, and acoustics measurements. Then, we selected 10 dwellings to carry out an indoor air quality winter campaign. This campaign included outdoor and indoor measurements of temperature, relative humidity, carbon dioxide, chemical pollutants (VOC, aldehydes). Inhabitant habits and building influence were studied through a complementary questionnaire survey. With this campaign, we were able to identify ventilation dysfunctions and to compare them with the national statistics on dwelling stock. The second part of the measurement campaign allowed us also to identify links between aeraulic diagnoses and indoor pollutant measurements.
doi_str_mv 10.1080/14733315.2017.1377393
format article
fullrecord <record><control><sourceid>hal_cross</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_01670490v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_HAL_hal_01670490v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-abaf861bb70a417e70698c4875bea3ac78b46d7198f36884b9aacb8a0c7123c73</originalsourceid><addsrcrecordid>eNp9kMFKAzEQhoMoWKuPIOTqYWuyyW6yN0uxrVDwooKnMJvNtpE0Kclq6du7a6tHLzMw8_3_4UPolpIJJZLcUy4YY7SY5ISKCWVCsIqdoVFOOM94P87RaGCyAbpEVyl9EMIKVooRen8zvrMOOhs83pnYhrgFrw0G32DrmxAiBhvxLjj32YHvEm4srH1INvV_nFM8j8brDXZhj403cX3Am7A16RpdtOCSuTntMXqdP77MltnqefE0m64yzSraZVBDK0ta14IAp8IIUlZScymK2gADLWTNy0bQSraslJLXFYCuJRAtaM60YGN0d-zdgFO7aLcQDyqAVcvpSg03QktBeEW-aM8WR1bHkFI07V-AEjW4VL8u1eBSnVz2uYdjzvofQfsQXaM6OLgQ29j7skmx_yu-ARZJeyU</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Ventilation performance and indoor air pollutants diagnosis in 21 French low energy homes</title><source>Taylor and Francis Science and Technology Collection</source><creator>Guyot, Gaëlle ; Melois, Adeline ; Bernard, Anne-Marie ; Coeudevez, Claire-Sophie ; Déoux, Suzanne ; Berlin, Sandra ; Parent, Enora ; Huet, Alexis ; Berthault, Sylvain ; Jobert, Romuald ; Labaume, Damien</creator><creatorcontrib>Guyot, Gaëlle ; Melois, Adeline ; Bernard, Anne-Marie ; Coeudevez, Claire-Sophie ; Déoux, Suzanne ; Berlin, Sandra ; Parent, Enora ; Huet, Alexis ; Berthault, Sylvain ; Jobert, Romuald ; Labaume, Damien</creatorcontrib><description>An important challenge for low energy buildings lies in the need to master airflows through the building envelope. This paper describes a campaign on 21 low-energy houses. First, we carried out an aeraulic measurement campaign on every dwelling including visual survey, airflow or pressure at the air-vents, ventilation duct airleakage, and acoustics measurements. Then, we selected 10 dwellings to carry out an indoor air quality winter campaign. This campaign included outdoor and indoor measurements of temperature, relative humidity, carbon dioxide, chemical pollutants (VOC, aldehydes). Inhabitant habits and building influence were studied through a complementary questionnaire survey. With this campaign, we were able to identify ventilation dysfunctions and to compare them with the national statistics on dwelling stock. The second part of the measurement campaign allowed us also to identify links between aeraulic diagnoses and indoor pollutant measurements.</description><identifier>ISSN: 1473-3315</identifier><identifier>EISSN: 2044-4044</identifier><identifier>DOI: 10.1080/14733315.2017.1377393</identifier><language>eng</language><publisher>Taylor &amp; Francis</publisher><subject>Civil Engineering ; Construction durable ; Eco-conception ; Engineering Sciences ; Environment and Society ; Environmental Sciences ; indoor air quality ; low energy single-family homes ; measurements ; Mechanics ; Risques ; Thermics ; Ventilation</subject><ispartof>The International journal of ventilation, 2018-07, Vol.17 (3), p.187-195</ispartof><rights>2017 Informa UK Limited, trading as Taylor &amp; Francis Group 2017</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-abaf861bb70a417e70698c4875bea3ac78b46d7198f36884b9aacb8a0c7123c73</citedby><cites>FETCH-LOGICAL-c391t-abaf861bb70a417e70698c4875bea3ac78b46d7198f36884b9aacb8a0c7123c73</cites><orcidid>0000-0001-7027-0864 ; 0000-0001-6112-9295</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,778,782,883,27911,27912</link.rule.ids><backlink>$$Uhttps://hal.science/hal-01670490$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Guyot, Gaëlle</creatorcontrib><creatorcontrib>Melois, Adeline</creatorcontrib><creatorcontrib>Bernard, Anne-Marie</creatorcontrib><creatorcontrib>Coeudevez, Claire-Sophie</creatorcontrib><creatorcontrib>Déoux, Suzanne</creatorcontrib><creatorcontrib>Berlin, Sandra</creatorcontrib><creatorcontrib>Parent, Enora</creatorcontrib><creatorcontrib>Huet, Alexis</creatorcontrib><creatorcontrib>Berthault, Sylvain</creatorcontrib><creatorcontrib>Jobert, Romuald</creatorcontrib><creatorcontrib>Labaume, Damien</creatorcontrib><title>Ventilation performance and indoor air pollutants diagnosis in 21 French low energy homes</title><title>The International journal of ventilation</title><description>An important challenge for low energy buildings lies in the need to master airflows through the building envelope. This paper describes a campaign on 21 low-energy houses. First, we carried out an aeraulic measurement campaign on every dwelling including visual survey, airflow or pressure at the air-vents, ventilation duct airleakage, and acoustics measurements. Then, we selected 10 dwellings to carry out an indoor air quality winter campaign. This campaign included outdoor and indoor measurements of temperature, relative humidity, carbon dioxide, chemical pollutants (VOC, aldehydes). Inhabitant habits and building influence were studied through a complementary questionnaire survey. With this campaign, we were able to identify ventilation dysfunctions and to compare them with the national statistics on dwelling stock. The second part of the measurement campaign allowed us also to identify links between aeraulic diagnoses and indoor pollutant measurements.</description><subject>Civil Engineering</subject><subject>Construction durable</subject><subject>Eco-conception</subject><subject>Engineering Sciences</subject><subject>Environment and Society</subject><subject>Environmental Sciences</subject><subject>indoor air quality</subject><subject>low energy single-family homes</subject><subject>measurements</subject><subject>Mechanics</subject><subject>Risques</subject><subject>Thermics</subject><subject>Ventilation</subject><issn>1473-3315</issn><issn>2044-4044</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kMFKAzEQhoMoWKuPIOTqYWuyyW6yN0uxrVDwooKnMJvNtpE0Kclq6du7a6tHLzMw8_3_4UPolpIJJZLcUy4YY7SY5ISKCWVCsIqdoVFOOM94P87RaGCyAbpEVyl9EMIKVooRen8zvrMOOhs83pnYhrgFrw0G32DrmxAiBhvxLjj32YHvEm4srH1INvV_nFM8j8brDXZhj403cX3Am7A16RpdtOCSuTntMXqdP77MltnqefE0m64yzSraZVBDK0ta14IAp8IIUlZScymK2gADLWTNy0bQSraslJLXFYCuJRAtaM60YGN0d-zdgFO7aLcQDyqAVcvpSg03QktBeEW-aM8WR1bHkFI07V-AEjW4VL8u1eBSnVz2uYdjzvofQfsQXaM6OLgQ29j7skmx_yu-ARZJeyU</recordid><startdate>20180703</startdate><enddate>20180703</enddate><creator>Guyot, Gaëlle</creator><creator>Melois, Adeline</creator><creator>Bernard, Anne-Marie</creator><creator>Coeudevez, Claire-Sophie</creator><creator>Déoux, Suzanne</creator><creator>Berlin, Sandra</creator><creator>Parent, Enora</creator><creator>Huet, Alexis</creator><creator>Berthault, Sylvain</creator><creator>Jobert, Romuald</creator><creator>Labaume, Damien</creator><general>Taylor &amp; Francis</general><general>VEETECH</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0001-7027-0864</orcidid><orcidid>https://orcid.org/0000-0001-6112-9295</orcidid></search><sort><creationdate>20180703</creationdate><title>Ventilation performance and indoor air pollutants diagnosis in 21 French low energy homes</title><author>Guyot, Gaëlle ; Melois, Adeline ; Bernard, Anne-Marie ; Coeudevez, Claire-Sophie ; Déoux, Suzanne ; Berlin, Sandra ; Parent, Enora ; Huet, Alexis ; Berthault, Sylvain ; Jobert, Romuald ; Labaume, Damien</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-abaf861bb70a417e70698c4875bea3ac78b46d7198f36884b9aacb8a0c7123c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Civil Engineering</topic><topic>Construction durable</topic><topic>Eco-conception</topic><topic>Engineering Sciences</topic><topic>Environment and Society</topic><topic>Environmental Sciences</topic><topic>indoor air quality</topic><topic>low energy single-family homes</topic><topic>measurements</topic><topic>Mechanics</topic><topic>Risques</topic><topic>Thermics</topic><topic>Ventilation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Guyot, Gaëlle</creatorcontrib><creatorcontrib>Melois, Adeline</creatorcontrib><creatorcontrib>Bernard, Anne-Marie</creatorcontrib><creatorcontrib>Coeudevez, Claire-Sophie</creatorcontrib><creatorcontrib>Déoux, Suzanne</creatorcontrib><creatorcontrib>Berlin, Sandra</creatorcontrib><creatorcontrib>Parent, Enora</creatorcontrib><creatorcontrib>Huet, Alexis</creatorcontrib><creatorcontrib>Berthault, Sylvain</creatorcontrib><creatorcontrib>Jobert, Romuald</creatorcontrib><creatorcontrib>Labaume, Damien</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>The International journal of ventilation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Guyot, Gaëlle</au><au>Melois, Adeline</au><au>Bernard, Anne-Marie</au><au>Coeudevez, Claire-Sophie</au><au>Déoux, Suzanne</au><au>Berlin, Sandra</au><au>Parent, Enora</au><au>Huet, Alexis</au><au>Berthault, Sylvain</au><au>Jobert, Romuald</au><au>Labaume, Damien</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ventilation performance and indoor air pollutants diagnosis in 21 French low energy homes</atitle><jtitle>The International journal of ventilation</jtitle><date>2018-07-03</date><risdate>2018</risdate><volume>17</volume><issue>3</issue><spage>187</spage><epage>195</epage><pages>187-195</pages><issn>1473-3315</issn><eissn>2044-4044</eissn><abstract>An important challenge for low energy buildings lies in the need to master airflows through the building envelope. This paper describes a campaign on 21 low-energy houses. First, we carried out an aeraulic measurement campaign on every dwelling including visual survey, airflow or pressure at the air-vents, ventilation duct airleakage, and acoustics measurements. Then, we selected 10 dwellings to carry out an indoor air quality winter campaign. This campaign included outdoor and indoor measurements of temperature, relative humidity, carbon dioxide, chemical pollutants (VOC, aldehydes). Inhabitant habits and building influence were studied through a complementary questionnaire survey. With this campaign, we were able to identify ventilation dysfunctions and to compare them with the national statistics on dwelling stock. The second part of the measurement campaign allowed us also to identify links between aeraulic diagnoses and indoor pollutant measurements.</abstract><pub>Taylor &amp; Francis</pub><doi>10.1080/14733315.2017.1377393</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0001-7027-0864</orcidid><orcidid>https://orcid.org/0000-0001-6112-9295</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1473-3315
ispartof The International journal of ventilation, 2018-07, Vol.17 (3), p.187-195
issn 1473-3315
2044-4044
language eng
recordid cdi_hal_primary_oai_HAL_hal_01670490v1
source Taylor and Francis Science and Technology Collection
subjects Civil Engineering
Construction durable
Eco-conception
Engineering Sciences
Environment and Society
Environmental Sciences
indoor air quality
low energy single-family homes
measurements
Mechanics
Risques
Thermics
Ventilation
title Ventilation performance and indoor air pollutants diagnosis in 21 French low energy homes
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T18%3A33%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ventilation%20performance%20and%20indoor%20air%20pollutants%20diagnosis%20in%2021%20French%20low%20energy%20homes&rft.jtitle=The%20International%20journal%20of%20ventilation&rft.au=Guyot,%20Ga%C3%ABlle&rft.date=2018-07-03&rft.volume=17&rft.issue=3&rft.spage=187&rft.epage=195&rft.pages=187-195&rft.issn=1473-3315&rft.eissn=2044-4044&rft_id=info:doi/10.1080/14733315.2017.1377393&rft_dat=%3Chal_cross%3Eoai_HAL_hal_01670490v1%3C/hal_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c391t-abaf861bb70a417e70698c4875bea3ac78b46d7198f36884b9aacb8a0c7123c73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true