1-Year Outcomes With the Evolut R Self-Expanding Transcatheter Aortic Valve: From the International FORWARD Study

This study sought to report the 1-year safety and efficacy outcomes in the FORWARD (CoreValve Evolut R FORWARD) study following transcatheter aortic valve replacement (TAVR) with the next-generation Evolut R device (Medtronic, Minneapolis, Minnesota) in routine clinical practice. The FORWARD study r...

Full description

Saved in:
Bibliographic Details
Published in:JACC. Cardiovascular interventions 2018-11, Vol.11 (22), p.2326-2334
Main Authors: Manoharan, Ganesh, Van Mieghem, Nicolas M, Windecker, Stephan, Bosmans, Johan, Bleiziffer, Sabine, Modine, Thomas, Linke, Axel, Scholtz, Werner, Chevalier, Bernard, Gooley, Robert, Zeng, Cathy, Oh, Jae K, Grube, Eberhard
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This study sought to report the 1-year safety and efficacy outcomes in the FORWARD (CoreValve Evolut R FORWARD) study following transcatheter aortic valve replacement (TAVR) with the next-generation Evolut R device (Medtronic, Minneapolis, Minnesota) in routine clinical practice. The FORWARD study reported low incidences of mortality, disabling stroke, and significant paravalvular leak following TAVR in routine clinical practice at 30 days. Longer-term results in large patient populations with the Evolut R self-expanding, repositionable transcatheter heart valve (THV) are lacking. This was a prospective, single-arm, multinational, multicenter, observational study investigating efficacy and safety following TAVR with the next-generation self-expanding THV. Between January and December 2016, 1,040 patients underwent attempted implant of the Evolut R self-expanding repositionable valve at 53 sites worldwide. An independent Clinical Events Committee adjudicated safety endpoints based on Valve Academic Research Consortium-2 definitions. An independent echocardiographic core laboratory evaluated all echocardiograms. The mean age was 81.8 ± 6.2 years, 64.8% were women, and patients had a mean Society of Thoracic Surgeons Predicted Risk of Mortality score of 5.5 ± 4.5% and EuroSCORE II of 5.7 ± 5.0%. The 1-year all-cause mortality rate was 8.9%, with a cardiovascular mortality rate of 6.9%. At 1 year, the incidence of disabling stroke was 2.1%, and a pacemaker was implanted in 19.7% of patients. The incidence of more than mild paravalvular leak was 1.2%. The FORWARD study demonstrated good safety and efficacy profiles for the next-generation Evolut R THV up to 1-year follow-up, with very low mortality and adverse events. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369).
ISSN:1936-8798
1876-7605
DOI:10.1016/j.jcin.2018.07.032