Experimental evaluation of vitrified waste as solid fillers used in thermocline thermal energy storage with parametric analysis

•4 m3 Pilot-scale thermocline TES for CSP.•Asbestos contained waste as solid filler in TES outperofrm alumina: 9.7% better discharge efficiencies, 16% lower thermocline thickness during charge and 23% during discharge, a 7% better charge/discharge time ratio.•10% bigger solid filler diameter results...

Full description

Saved in:
Bibliographic Details
Published in:Journal of energy storage 2020-06, Vol.29, p.101285, Article 101285
Main Authors: Keilany, M.A., Milhé, M., Bézian, J-J., Falcoz, Q., Flamant, G.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c374t-b7fa95041978e796be57662347574425cf6d39b9e614f6f89a2736f2ca40098a3
cites cdi_FETCH-LOGICAL-c374t-b7fa95041978e796be57662347574425cf6d39b9e614f6f89a2736f2ca40098a3
container_end_page
container_issue
container_start_page 101285
container_title Journal of energy storage
container_volume 29
creator Keilany, M.A.
Milhé, M.
Bézian, J-J.
Falcoz, Q.
Flamant, G.
description •4 m3 Pilot-scale thermocline TES for CSP.•Asbestos contained waste as solid filler in TES outperofrm alumina: 9.7% better discharge efficiencies, 16% lower thermocline thickness during charge and 23% during discharge, a 7% better charge/discharge time ratio.•10% bigger solid filler diameter results a 2.2% wider thermocline thickness and 1.4% reduction in discharge efficiency after the optimum diameter. This work presents the first use of Cofalit® (vitrified asbestos-containing waste) as a solid filler in pilot-scale thermocline thermal energy storage (TES). The thermocline size is 4 m³ connected to the MicroSol-R installation at the PROMES research facility in Odeillo, France. The study compares the thermal performance of the thermocline filled with Cofalit® to the reference case of alumina spheres for typical charge and discharge operations. It evaluates the actual thermal behavior of thermocline considering three leading performance indicators: process duration, thermocline thickness, and process efficiency. The investigation shows a 22% shorter charge duration in Cofalit® compared to alumina and 16% shorter discharge duration. Cofalit® exhibits about 16% lower thermocline thickness during both charge and discharge compared to alumina. The charge efficiency is slightly better in Cofalit® than alumina with an efficiency of 82% and 78%, respectively. Also, Cofalit® has a better discharge efficiency, 90% with respect to 84% for alumina. These results confim a good thermal performance of Cofalit® as filler material in thermocline TES. Considering the cost-saving and positive environmental impact of using Cofalit® as well as the good thermal performance of the thermocline filled with it, Cofalit® appears a very good filler material in TES. The obtained temperatures from radial positions indicate no significant variation during charge and discharge, and this confirms the one-dimensional thermal behavior of this setup. A parametric analysis is performed using a 1D continuous solid (C-S) model to investigate the influence of particle diameter, porosity, thermal conductivity, and volumetric heat capacity on the thermal performance of the thermocline. The analysis confirms the experimental findings, and it indicates that about a 10.9% longer process duration is associated with a 10% larger volumetric heat capacity and less affected with other parameters. Thermocline thickness is mainly affected by the diameter as well as the volumetric heat capacity of the solid
doi_str_mv 10.1016/j.est.2020.101285
format article
fullrecord <record><control><sourceid>hal_cross</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_02498627v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2352152X19311910</els_id><sourcerecordid>oai_HAL_hal_02498627v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-c374t-b7fa95041978e796be57662347574425cf6d39b9e614f6f89a2736f2ca40098a3</originalsourceid><addsrcrecordid>eNp9kE9LwzAYxosoOHQfwFuuHjqTtE0aPA1RJwy8KHgL79I3W0bWjiRWd_Kr21nx6On9-3vgebLsitEZo0zcbGcY04xT_jPzujrJJryoeM6qoj796_nbeTaNcUvpAFWMKTHJvu4_9xjcDtsEnmAP_h2S61rSWdK7FJx12JAPiAkJRBI77xpinfcYInmPw821JG0w7DrjXYtjf5RqMawPJKYuwBrJh0sbsocAOxxEDYEW_CG6eJmdWfARp7_1Int9uH-5W-TL58enu_kyN4UsU76SFlRFS6ZkjVKJFVZSCF6UspJlyStjRVOolULBSitsrYDLQlhuoKRU1VBcZNej7ga83g-GIRx0B04v5kt93FFeqlpw2bPhl42_JnQxBrR_AKP6GLje6iFwfQxcj4EPzO3I4GCidxh0NA5bg40LaJJuOvcP_Q2gWoow</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Experimental evaluation of vitrified waste as solid fillers used in thermocline thermal energy storage with parametric analysis</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Keilany, M.A. ; Milhé, M. ; Bézian, J-J. ; Falcoz, Q. ; Flamant, G.</creator><creatorcontrib>Keilany, M.A. ; Milhé, M. ; Bézian, J-J. ; Falcoz, Q. ; Flamant, G.</creatorcontrib><description>•4 m3 Pilot-scale thermocline TES for CSP.•Asbestos contained waste as solid filler in TES outperofrm alumina: 9.7% better discharge efficiencies, 16% lower thermocline thickness during charge and 23% during discharge, a 7% better charge/discharge time ratio.•10% bigger solid filler diameter results a 2.2% wider thermocline thickness and 1.4% reduction in discharge efficiency after the optimum diameter. This work presents the first use of Cofalit® (vitrified asbestos-containing waste) as a solid filler in pilot-scale thermocline thermal energy storage (TES). The thermocline size is 4 m³ connected to the MicroSol-R installation at the PROMES research facility in Odeillo, France. The study compares the thermal performance of the thermocline filled with Cofalit® to the reference case of alumina spheres for typical charge and discharge operations. It evaluates the actual thermal behavior of thermocline considering three leading performance indicators: process duration, thermocline thickness, and process efficiency. The investigation shows a 22% shorter charge duration in Cofalit® compared to alumina and 16% shorter discharge duration. Cofalit® exhibits about 16% lower thermocline thickness during both charge and discharge compared to alumina. The charge efficiency is slightly better in Cofalit® than alumina with an efficiency of 82% and 78%, respectively. Also, Cofalit® has a better discharge efficiency, 90% with respect to 84% for alumina. These results confim a good thermal performance of Cofalit® as filler material in thermocline TES. Considering the cost-saving and positive environmental impact of using Cofalit® as well as the good thermal performance of the thermocline filled with it, Cofalit® appears a very good filler material in TES. The obtained temperatures from radial positions indicate no significant variation during charge and discharge, and this confirms the one-dimensional thermal behavior of this setup. A parametric analysis is performed using a 1D continuous solid (C-S) model to investigate the influence of particle diameter, porosity, thermal conductivity, and volumetric heat capacity on the thermal performance of the thermocline. The analysis confirms the experimental findings, and it indicates that about a 10.9% longer process duration is associated with a 10% larger volumetric heat capacity and less affected with other parameters. Thermocline thickness is mainly affected by the diameter as well as the volumetric heat capacity of the solid filler; it grows 2.2% for each 10% diameter increase and around 3.23% for doubling the volumetric heat capacity. Charge efficiency demonstrates independency from evaluated properties. While discharge efficiency increases sharply at a tiny particle diameter before an optimum diameter value is reached, then it starts to decrease by 1.4% to each 10% bigger diameter.</description><identifier>ISSN: 2352-152X</identifier><identifier>EISSN: 2352-1538</identifier><identifier>DOI: 10.1016/j.est.2020.101285</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Discharge/charge efficiencies ; Engineering Sciences ; Materials ; Mechanics ; Performance parameters ; Pilot-scale thermocline for CSP ; Thermal energy storage ; Thermics ; Thermolicne thickness</subject><ispartof>Journal of energy storage, 2020-06, Vol.29, p.101285, Article 101285</ispartof><rights>2020 Elsevier Ltd</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c374t-b7fa95041978e796be57662347574425cf6d39b9e614f6f89a2736f2ca40098a3</citedby><cites>FETCH-LOGICAL-c374t-b7fa95041978e796be57662347574425cf6d39b9e614f6f89a2736f2ca40098a3</cites><orcidid>0000-0003-4562-8515 ; 0000-0001-7697-044X ; 0000-0001-5667-2488 ; 0000-0001-6947-0623</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://imt-mines-albi.hal.science/hal-02498627$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Keilany, M.A.</creatorcontrib><creatorcontrib>Milhé, M.</creatorcontrib><creatorcontrib>Bézian, J-J.</creatorcontrib><creatorcontrib>Falcoz, Q.</creatorcontrib><creatorcontrib>Flamant, G.</creatorcontrib><title>Experimental evaluation of vitrified waste as solid fillers used in thermocline thermal energy storage with parametric analysis</title><title>Journal of energy storage</title><description>•4 m3 Pilot-scale thermocline TES for CSP.•Asbestos contained waste as solid filler in TES outperofrm alumina: 9.7% better discharge efficiencies, 16% lower thermocline thickness during charge and 23% during discharge, a 7% better charge/discharge time ratio.•10% bigger solid filler diameter results a 2.2% wider thermocline thickness and 1.4% reduction in discharge efficiency after the optimum diameter. This work presents the first use of Cofalit® (vitrified asbestos-containing waste) as a solid filler in pilot-scale thermocline thermal energy storage (TES). The thermocline size is 4 m³ connected to the MicroSol-R installation at the PROMES research facility in Odeillo, France. The study compares the thermal performance of the thermocline filled with Cofalit® to the reference case of alumina spheres for typical charge and discharge operations. It evaluates the actual thermal behavior of thermocline considering three leading performance indicators: process duration, thermocline thickness, and process efficiency. The investigation shows a 22% shorter charge duration in Cofalit® compared to alumina and 16% shorter discharge duration. Cofalit® exhibits about 16% lower thermocline thickness during both charge and discharge compared to alumina. The charge efficiency is slightly better in Cofalit® than alumina with an efficiency of 82% and 78%, respectively. Also, Cofalit® has a better discharge efficiency, 90% with respect to 84% for alumina. These results confim a good thermal performance of Cofalit® as filler material in thermocline TES. Considering the cost-saving and positive environmental impact of using Cofalit® as well as the good thermal performance of the thermocline filled with it, Cofalit® appears a very good filler material in TES. The obtained temperatures from radial positions indicate no significant variation during charge and discharge, and this confirms the one-dimensional thermal behavior of this setup. A parametric analysis is performed using a 1D continuous solid (C-S) model to investigate the influence of particle diameter, porosity, thermal conductivity, and volumetric heat capacity on the thermal performance of the thermocline. The analysis confirms the experimental findings, and it indicates that about a 10.9% longer process duration is associated with a 10% larger volumetric heat capacity and less affected with other parameters. Thermocline thickness is mainly affected by the diameter as well as the volumetric heat capacity of the solid filler; it grows 2.2% for each 10% diameter increase and around 3.23% for doubling the volumetric heat capacity. Charge efficiency demonstrates independency from evaluated properties. While discharge efficiency increases sharply at a tiny particle diameter before an optimum diameter value is reached, then it starts to decrease by 1.4% to each 10% bigger diameter.</description><subject>Discharge/charge efficiencies</subject><subject>Engineering Sciences</subject><subject>Materials</subject><subject>Mechanics</subject><subject>Performance parameters</subject><subject>Pilot-scale thermocline for CSP</subject><subject>Thermal energy storage</subject><subject>Thermics</subject><subject>Thermolicne thickness</subject><issn>2352-152X</issn><issn>2352-1538</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kE9LwzAYxosoOHQfwFuuHjqTtE0aPA1RJwy8KHgL79I3W0bWjiRWd_Kr21nx6On9-3vgebLsitEZo0zcbGcY04xT_jPzujrJJryoeM6qoj796_nbeTaNcUvpAFWMKTHJvu4_9xjcDtsEnmAP_h2S61rSWdK7FJx12JAPiAkJRBI77xpinfcYInmPw821JG0w7DrjXYtjf5RqMawPJKYuwBrJh0sbsocAOxxEDYEW_CG6eJmdWfARp7_1Int9uH-5W-TL58enu_kyN4UsU76SFlRFS6ZkjVKJFVZSCF6UspJlyStjRVOolULBSitsrYDLQlhuoKRU1VBcZNej7ga83g-GIRx0B04v5kt93FFeqlpw2bPhl42_JnQxBrR_AKP6GLje6iFwfQxcj4EPzO3I4GCidxh0NA5bg40LaJJuOvcP_Q2gWoow</recordid><startdate>20200601</startdate><enddate>20200601</enddate><creator>Keilany, M.A.</creator><creator>Milhé, M.</creator><creator>Bézian, J-J.</creator><creator>Falcoz, Q.</creator><creator>Flamant, G.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0003-4562-8515</orcidid><orcidid>https://orcid.org/0000-0001-7697-044X</orcidid><orcidid>https://orcid.org/0000-0001-5667-2488</orcidid><orcidid>https://orcid.org/0000-0001-6947-0623</orcidid></search><sort><creationdate>20200601</creationdate><title>Experimental evaluation of vitrified waste as solid fillers used in thermocline thermal energy storage with parametric analysis</title><author>Keilany, M.A. ; Milhé, M. ; Bézian, J-J. ; Falcoz, Q. ; Flamant, G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c374t-b7fa95041978e796be57662347574425cf6d39b9e614f6f89a2736f2ca40098a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Discharge/charge efficiencies</topic><topic>Engineering Sciences</topic><topic>Materials</topic><topic>Mechanics</topic><topic>Performance parameters</topic><topic>Pilot-scale thermocline for CSP</topic><topic>Thermal energy storage</topic><topic>Thermics</topic><topic>Thermolicne thickness</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Keilany, M.A.</creatorcontrib><creatorcontrib>Milhé, M.</creatorcontrib><creatorcontrib>Bézian, J-J.</creatorcontrib><creatorcontrib>Falcoz, Q.</creatorcontrib><creatorcontrib>Flamant, G.</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Journal of energy storage</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Keilany, M.A.</au><au>Milhé, M.</au><au>Bézian, J-J.</au><au>Falcoz, Q.</au><au>Flamant, G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental evaluation of vitrified waste as solid fillers used in thermocline thermal energy storage with parametric analysis</atitle><jtitle>Journal of energy storage</jtitle><date>2020-06-01</date><risdate>2020</risdate><volume>29</volume><spage>101285</spage><pages>101285-</pages><artnum>101285</artnum><issn>2352-152X</issn><eissn>2352-1538</eissn><abstract>•4 m3 Pilot-scale thermocline TES for CSP.•Asbestos contained waste as solid filler in TES outperofrm alumina: 9.7% better discharge efficiencies, 16% lower thermocline thickness during charge and 23% during discharge, a 7% better charge/discharge time ratio.•10% bigger solid filler diameter results a 2.2% wider thermocline thickness and 1.4% reduction in discharge efficiency after the optimum diameter. This work presents the first use of Cofalit® (vitrified asbestos-containing waste) as a solid filler in pilot-scale thermocline thermal energy storage (TES). The thermocline size is 4 m³ connected to the MicroSol-R installation at the PROMES research facility in Odeillo, France. The study compares the thermal performance of the thermocline filled with Cofalit® to the reference case of alumina spheres for typical charge and discharge operations. It evaluates the actual thermal behavior of thermocline considering three leading performance indicators: process duration, thermocline thickness, and process efficiency. The investigation shows a 22% shorter charge duration in Cofalit® compared to alumina and 16% shorter discharge duration. Cofalit® exhibits about 16% lower thermocline thickness during both charge and discharge compared to alumina. The charge efficiency is slightly better in Cofalit® than alumina with an efficiency of 82% and 78%, respectively. Also, Cofalit® has a better discharge efficiency, 90% with respect to 84% for alumina. These results confim a good thermal performance of Cofalit® as filler material in thermocline TES. Considering the cost-saving and positive environmental impact of using Cofalit® as well as the good thermal performance of the thermocline filled with it, Cofalit® appears a very good filler material in TES. The obtained temperatures from radial positions indicate no significant variation during charge and discharge, and this confirms the one-dimensional thermal behavior of this setup. A parametric analysis is performed using a 1D continuous solid (C-S) model to investigate the influence of particle diameter, porosity, thermal conductivity, and volumetric heat capacity on the thermal performance of the thermocline. The analysis confirms the experimental findings, and it indicates that about a 10.9% longer process duration is associated with a 10% larger volumetric heat capacity and less affected with other parameters. Thermocline thickness is mainly affected by the diameter as well as the volumetric heat capacity of the solid filler; it grows 2.2% for each 10% diameter increase and around 3.23% for doubling the volumetric heat capacity. Charge efficiency demonstrates independency from evaluated properties. While discharge efficiency increases sharply at a tiny particle diameter before an optimum diameter value is reached, then it starts to decrease by 1.4% to each 10% bigger diameter.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.est.2020.101285</doi><orcidid>https://orcid.org/0000-0003-4562-8515</orcidid><orcidid>https://orcid.org/0000-0001-7697-044X</orcidid><orcidid>https://orcid.org/0000-0001-5667-2488</orcidid><orcidid>https://orcid.org/0000-0001-6947-0623</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2352-152X
ispartof Journal of energy storage, 2020-06, Vol.29, p.101285, Article 101285
issn 2352-152X
2352-1538
language eng
recordid cdi_hal_primary_oai_HAL_hal_02498627v1
source ScienceDirect Freedom Collection 2022-2024
subjects Discharge/charge efficiencies
Engineering Sciences
Materials
Mechanics
Performance parameters
Pilot-scale thermocline for CSP
Thermal energy storage
Thermics
Thermolicne thickness
title Experimental evaluation of vitrified waste as solid fillers used in thermocline thermal energy storage with parametric analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T21%3A06%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20evaluation%20of%20vitrified%20waste%20as%20solid%20fillers%20used%20in%20thermocline%20thermal%20energy%20storage%20with%20parametric%20analysis&rft.jtitle=Journal%20of%20energy%20storage&rft.au=Keilany,%20M.A.&rft.date=2020-06-01&rft.volume=29&rft.spage=101285&rft.pages=101285-&rft.artnum=101285&rft.issn=2352-152X&rft.eissn=2352-1538&rft_id=info:doi/10.1016/j.est.2020.101285&rft_dat=%3Chal_cross%3Eoai_HAL_hal_02498627v1%3C/hal_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c374t-b7fa95041978e796be57662347574425cf6d39b9e614f6f89a2736f2ca40098a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true