DPC controlled three-phase active filter for power quality improvement
This paper presents a new control method entitled direct power control (DPC) for shunt active power filtering (5th, 7th, 11th, …) (SAPF), which is applied to eliminate line current harmonics and compensate reactive power. Its main goal is to rebuild active and reactive powers to be compared to refer...
Saved in:
Published in: | International journal of electrical power & energy systems 2008-10, Vol.30 (8), p.476-485 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c370t-24ddd8090f9bfa9c992fbcd785a5251c544943adc176c3a510a5b0255d9971583 |
---|---|
cites | cdi_FETCH-LOGICAL-c370t-24ddd8090f9bfa9c992fbcd785a5251c544943adc176c3a510a5b0255d9971583 |
container_end_page | 485 |
container_issue | 8 |
container_start_page | 476 |
container_title | International journal of electrical power & energy systems |
container_volume | 30 |
creator | Chaoui, Abdelmadjid Krim, Fateh Gaubert, Jean-Paul Rambault, Laurent |
description | This paper presents a new control method entitled direct power control (DPC) for shunt active power filtering (5th, 7th, 11th, …) (SAPF), which is applied to eliminate line current harmonics and compensate reactive power. Its main goal is to rebuild active and reactive powers to be compared to references values using hysteresis control. The outputs of hysteresis controllers associated with a switching table, control the instantaneous active and reactive power by selecting the optimum switching state of the voltage source inverter (VSI). A theoretical analysis with a complete simulation of the system and experimental results are presented to prove the excellent performance of the proposed control technique. |
doi_str_mv | 10.1016/j.ijepes.2008.04.009 |
format | article |
fullrecord | <record><control><sourceid>elsevier_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03204280v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0142061508000318</els_id><sourcerecordid>S0142061508000318</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-24ddd8090f9bfa9c992fbcd785a5251c544943adc176c3a510a5b0255d9971583</originalsourceid><addsrcrecordid>eNp9kLFOwzAQhi0EEqXwBgxZGBgSzo6dxAtSVShFqgQDzJZrX1RHaRLsENS3J1VQR6Y7nf7vTvcRckshoUCzhypxFXYYEgZQJMATAHlGZrTIZZwKmp-TGVDOYsiouCRXIVQAkEvOZmT19L6MTNv0vq1rtFG_84hxt9MBI216N2BUurpHH5Wtj7r2Z-y-vnXt-kPk9p1vB9xj01-Ti1LXAW_-6px8rp4_lut48_byulxsYpPm0MeMW2sLkFDKbamlkZKVW2PzQmjBBDWCc8lTbQ3NM5NqQUGLLTAhrJQ5FUU6J_fT3p2uVefdXvuDarVT68VGHWeQMuCsgIGOWT5ljW9D8FieAArq6E1VavKmjt4UcDV6G7G7Cet0MLouvW6MCyeWQVYAozDmHqccjv8ODr0KxmFj0DqPple2df8f-gUf8oRy</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>DPC controlled three-phase active filter for power quality improvement</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Chaoui, Abdelmadjid ; Krim, Fateh ; Gaubert, Jean-Paul ; Rambault, Laurent</creator><creatorcontrib>Chaoui, Abdelmadjid ; Krim, Fateh ; Gaubert, Jean-Paul ; Rambault, Laurent</creatorcontrib><description>This paper presents a new control method entitled direct power control (DPC) for shunt active power filtering (5th, 7th, 11th, …) (SAPF), which is applied to eliminate line current harmonics and compensate reactive power. Its main goal is to rebuild active and reactive powers to be compared to references values using hysteresis control. The outputs of hysteresis controllers associated with a switching table, control the instantaneous active and reactive power by selecting the optimum switching state of the voltage source inverter (VSI). A theoretical analysis with a complete simulation of the system and experimental results are presented to prove the excellent performance of the proposed control technique.</description><identifier>ISSN: 0142-0615</identifier><identifier>EISSN: 1879-3517</identifier><identifier>DOI: 10.1016/j.ijepes.2008.04.009</identifier><identifier>CODEN: IEPSDC</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; Capacitors. Resistors. Filters ; Computer Science ; Electrical engineering. Electrical power engineering ; Electrical machines ; Electrical power engineering ; Exact sciences and technology ; Harmonics ; Hysteresis comparator ; Instantaneous power ; Operation. Load control. Reliability ; Power electronics, power supplies ; Power networks and lines ; Power quality ; Regulation and control ; Shunt active filters ; Switching table ; Various equipment and components</subject><ispartof>International journal of electrical power & energy systems, 2008-10, Vol.30 (8), p.476-485</ispartof><rights>2008 Elsevier Ltd</rights><rights>2008 INIST-CNRS</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-24ddd8090f9bfa9c992fbcd785a5251c544943adc176c3a510a5b0255d9971583</citedby><cites>FETCH-LOGICAL-c370t-24ddd8090f9bfa9c992fbcd785a5251c544943adc176c3a510a5b0255d9971583</cites><orcidid>0000-0002-7145-411X ; 0000-0002-2104-8535</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=20680210$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-03204280$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Chaoui, Abdelmadjid</creatorcontrib><creatorcontrib>Krim, Fateh</creatorcontrib><creatorcontrib>Gaubert, Jean-Paul</creatorcontrib><creatorcontrib>Rambault, Laurent</creatorcontrib><title>DPC controlled three-phase active filter for power quality improvement</title><title>International journal of electrical power & energy systems</title><description>This paper presents a new control method entitled direct power control (DPC) for shunt active power filtering (5th, 7th, 11th, …) (SAPF), which is applied to eliminate line current harmonics and compensate reactive power. Its main goal is to rebuild active and reactive powers to be compared to references values using hysteresis control. The outputs of hysteresis controllers associated with a switching table, control the instantaneous active and reactive power by selecting the optimum switching state of the voltage source inverter (VSI). A theoretical analysis with a complete simulation of the system and experimental results are presented to prove the excellent performance of the proposed control technique.</description><subject>Applied sciences</subject><subject>Capacitors. Resistors. Filters</subject><subject>Computer Science</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Electrical machines</subject><subject>Electrical power engineering</subject><subject>Exact sciences and technology</subject><subject>Harmonics</subject><subject>Hysteresis comparator</subject><subject>Instantaneous power</subject><subject>Operation. Load control. Reliability</subject><subject>Power electronics, power supplies</subject><subject>Power networks and lines</subject><subject>Power quality</subject><subject>Regulation and control</subject><subject>Shunt active filters</subject><subject>Switching table</subject><subject>Various equipment and components</subject><issn>0142-0615</issn><issn>1879-3517</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNp9kLFOwzAQhi0EEqXwBgxZGBgSzo6dxAtSVShFqgQDzJZrX1RHaRLsENS3J1VQR6Y7nf7vTvcRckshoUCzhypxFXYYEgZQJMATAHlGZrTIZZwKmp-TGVDOYsiouCRXIVQAkEvOZmT19L6MTNv0vq1rtFG_84hxt9MBI216N2BUurpHH5Wtj7r2Z-y-vnXt-kPk9p1vB9xj01-Ti1LXAW_-6px8rp4_lut48_byulxsYpPm0MeMW2sLkFDKbamlkZKVW2PzQmjBBDWCc8lTbQ3NM5NqQUGLLTAhrJQ5FUU6J_fT3p2uVefdXvuDarVT68VGHWeQMuCsgIGOWT5ljW9D8FieAArq6E1VavKmjt4UcDV6G7G7Cet0MLouvW6MCyeWQVYAozDmHqccjv8ODr0KxmFj0DqPple2df8f-gUf8oRy</recordid><startdate>20081001</startdate><enddate>20081001</enddate><creator>Chaoui, Abdelmadjid</creator><creator>Krim, Fateh</creator><creator>Gaubert, Jean-Paul</creator><creator>Rambault, Laurent</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><orcidid>https://orcid.org/0000-0002-7145-411X</orcidid><orcidid>https://orcid.org/0000-0002-2104-8535</orcidid></search><sort><creationdate>20081001</creationdate><title>DPC controlled three-phase active filter for power quality improvement</title><author>Chaoui, Abdelmadjid ; Krim, Fateh ; Gaubert, Jean-Paul ; Rambault, Laurent</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-24ddd8090f9bfa9c992fbcd785a5251c544943adc176c3a510a5b0255d9971583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Applied sciences</topic><topic>Capacitors. Resistors. Filters</topic><topic>Computer Science</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Electrical machines</topic><topic>Electrical power engineering</topic><topic>Exact sciences and technology</topic><topic>Harmonics</topic><topic>Hysteresis comparator</topic><topic>Instantaneous power</topic><topic>Operation. Load control. Reliability</topic><topic>Power electronics, power supplies</topic><topic>Power networks and lines</topic><topic>Power quality</topic><topic>Regulation and control</topic><topic>Shunt active filters</topic><topic>Switching table</topic><topic>Various equipment and components</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chaoui, Abdelmadjid</creatorcontrib><creatorcontrib>Krim, Fateh</creatorcontrib><creatorcontrib>Gaubert, Jean-Paul</creatorcontrib><creatorcontrib>Rambault, Laurent</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>International journal of electrical power & energy systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chaoui, Abdelmadjid</au><au>Krim, Fateh</au><au>Gaubert, Jean-Paul</au><au>Rambault, Laurent</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>DPC controlled three-phase active filter for power quality improvement</atitle><jtitle>International journal of electrical power & energy systems</jtitle><date>2008-10-01</date><risdate>2008</risdate><volume>30</volume><issue>8</issue><spage>476</spage><epage>485</epage><pages>476-485</pages><issn>0142-0615</issn><eissn>1879-3517</eissn><coden>IEPSDC</coden><abstract>This paper presents a new control method entitled direct power control (DPC) for shunt active power filtering (5th, 7th, 11th, …) (SAPF), which is applied to eliminate line current harmonics and compensate reactive power. Its main goal is to rebuild active and reactive powers to be compared to references values using hysteresis control. The outputs of hysteresis controllers associated with a switching table, control the instantaneous active and reactive power by selecting the optimum switching state of the voltage source inverter (VSI). A theoretical analysis with a complete simulation of the system and experimental results are presented to prove the excellent performance of the proposed control technique.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.ijepes.2008.04.009</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-7145-411X</orcidid><orcidid>https://orcid.org/0000-0002-2104-8535</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0142-0615 |
ispartof | International journal of electrical power & energy systems, 2008-10, Vol.30 (8), p.476-485 |
issn | 0142-0615 1879-3517 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_03204280v1 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Applied sciences Capacitors. Resistors. Filters Computer Science Electrical engineering. Electrical power engineering Electrical machines Electrical power engineering Exact sciences and technology Harmonics Hysteresis comparator Instantaneous power Operation. Load control. Reliability Power electronics, power supplies Power networks and lines Power quality Regulation and control Shunt active filters Switching table Various equipment and components |
title | DPC controlled three-phase active filter for power quality improvement |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T06%3A15%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=DPC%20controlled%20three-phase%20active%20filter%20for%20power%20quality%20improvement&rft.jtitle=International%20journal%20of%20electrical%20power%20&%20energy%20systems&rft.au=Chaoui,%20Abdelmadjid&rft.date=2008-10-01&rft.volume=30&rft.issue=8&rft.spage=476&rft.epage=485&rft.pages=476-485&rft.issn=0142-0615&rft.eissn=1879-3517&rft.coden=IEPSDC&rft_id=info:doi/10.1016/j.ijepes.2008.04.009&rft_dat=%3Celsevier_hal_p%3ES0142061508000318%3C/elsevier_hal_p%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c370t-24ddd8090f9bfa9c992fbcd785a5251c544943adc176c3a510a5b0255d9971583%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |