Deposition of hydrogen chloride gas on copper wafer depending on humidity and HCl concentration

Residual volatile HCl acid remaining on the wafer surface after certain microelectronic fabrication can lead to the yield defectiveness of integrated circuits made of copper (Cu). The control of HCl contamination is a key point to avoid the yield loss. In order to elucidate the deposition mechanism...

Full description

Saved in:
Bibliographic Details
Published in:Microelectronic engineering 2019-02, Vol.207, p.1-6
Main Authors: Tran, Minh-Phuong, Gonzalez-Aguirre, Paola, Beitia, Carlos, Lundgren, Jorgen, Moon, Sung-In, Fontaine, Hervé
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Residual volatile HCl acid remaining on the wafer surface after certain microelectronic fabrication can lead to the yield defectiveness of integrated circuits made of copper (Cu). The control of HCl contamination is a key point to avoid the yield loss. In order to elucidate the deposition mechanism of HCl on copper surface, Cu-coated wafers were exposed to HCl at different HCl airborne concentrations (20–450 ppbv) and at different relative humidity (