Loading…

Which method should be chosen to estimate the oxygen cost of walking in post-stroke individuals?

•Oxygen cost provides access to the energy expenditure of walking in stroke individuals.•Oxygen cost can be estimated regardless of the method used to measure walking speed.•Estimation of the oxygen cost by gait speed has a good test retest reliability. The oxygen cost of walking (Cw) represents the...

Full description

Saved in:
Bibliographic Details
Published in:Gait & posture 2021-09, Vol.89, p.217-219
Main Authors: Compagnat, Maxence, Mandigout, Stéphane, Perrochon, Anaick, Salle, Jean Yves, Daviet, Jean Christophe
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c427t-35906bf835e1629584870e08eaaa9f01640efd24e90408c5636a462ad1caba23
cites cdi_FETCH-LOGICAL-c427t-35906bf835e1629584870e08eaaa9f01640efd24e90408c5636a462ad1caba23
container_end_page 219
container_issue
container_start_page 217
container_title Gait & posture
container_volume 89
creator Compagnat, Maxence
Mandigout, Stéphane
Perrochon, Anaick
Salle, Jean Yves
Daviet, Jean Christophe
description •Oxygen cost provides access to the energy expenditure of walking in stroke individuals.•Oxygen cost can be estimated regardless of the method used to measure walking speed.•Estimation of the oxygen cost by gait speed has a good test retest reliability. The oxygen cost of walking (Cw) represents the energy expenditure involved in walking, which is a major concern when quantifying physical activity in stroke. Recent studies have reported that Cw may be estimated accurately with a prediction equation using the self-self-selected walking speed (Sfree). To evaluate the validity of Cw estimates according to different modalities of Sfree measurements (10-m walking test, 6-minute walking test, GaitRite system). Twenty-one stroke individuals in subacute phase who were able to walk without human aid were included. Cw was estimated from the walking speed measured during a 10-m walking test, a 6-minute walking test and a recording on a GaitRite system. The values of the Cw estimates were compared to those measured by a respiratory gas exchange analyzer (Metamax3b). The findings showed that there is no significant difference between the Cw measured by Metamax3b and the Cw estimates regardless of the modalities used to measure Sfree (Fvalue = 0.02; pvalue = 0.99). The mean bias between Cw measured by the Metamax3b and those estimated using the different Sfree measurement modalities was less than 2.5 % of the mean Cw value. Test retest reliability was excellent with an intraclass correlation coefficient higher than 0.95. in stroke survivors who are able to walk independently without human aid, the use of a 10-m walking test, a 6-minute walking test or a GaitRite recording can be considered validated for estimating Cw.
doi_str_mv 10.1016/j.gaitpost.2021.07.017
format article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_03517308v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S096663622100268X</els_id><sourcerecordid>2559425614</sourcerecordid><originalsourceid>FETCH-LOGICAL-c427t-35906bf835e1629584870e08eaaa9f01640efd24e90408c5636a462ad1caba23</originalsourceid><addsrcrecordid>eNqFUU1vEzEUtBCIpoW_gHwsh90-f673VKoKKFIkLpU4Gsf7Nut0s07XTqD_HkdpufY0eqN5895oCPnEoGbA9NWmXruQdzHlmgNnNTQ1sOYNWTDTtBXnrH1LFtBqXWmh-Rk5T2kDAFIY_p6cCSmUaZRZkN-_huAHusU8xI6mIe7Hjq6Q-iEmnGiOFFMOW5eR5gFp_Pu0LrQvd2ns6R83PoRpTcNEj69UKc_xAcvYhUPo9m5M1x_Iu74gfnzGC3L_7ev97V21_Pn9x-3NsvKSN7kSqgW96o1QyDRvlZGmAQSDzrm2L4klYN9xiS1IMF6VVE5q7jrm3cpxcUE-n2wHN9rdXD6en2x0wd7dLO2RA6FYI8AcWNFenrS7OT7uSz67DcnjOLoJ4z5ZrlQrudJMFqk-Sf0cU5qx_-_NwB6LsBv7UoQ9FmGhsaWIsvjltIgl8yHgbJMPOHnswow-2y6G1yz-AX6Xkvs</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2559425614</pqid></control><display><type>article</type><title>Which method should be chosen to estimate the oxygen cost of walking in post-stroke individuals?</title><source>ScienceDirect Freedom Collection</source><creator>Compagnat, Maxence ; Mandigout, Stéphane ; Perrochon, Anaick ; Salle, Jean Yves ; Daviet, Jean Christophe</creator><creatorcontrib>Compagnat, Maxence ; Mandigout, Stéphane ; Perrochon, Anaick ; Salle, Jean Yves ; Daviet, Jean Christophe</creatorcontrib><description>•Oxygen cost provides access to the energy expenditure of walking in stroke individuals.•Oxygen cost can be estimated regardless of the method used to measure walking speed.•Estimation of the oxygen cost by gait speed has a good test retest reliability. The oxygen cost of walking (Cw) represents the energy expenditure involved in walking, which is a major concern when quantifying physical activity in stroke. Recent studies have reported that Cw may be estimated accurately with a prediction equation using the self-self-selected walking speed (Sfree). To evaluate the validity of Cw estimates according to different modalities of Sfree measurements (10-m walking test, 6-minute walking test, GaitRite system). Twenty-one stroke individuals in subacute phase who were able to walk without human aid were included. Cw was estimated from the walking speed measured during a 10-m walking test, a 6-minute walking test and a recording on a GaitRite system. The values of the Cw estimates were compared to those measured by a respiratory gas exchange analyzer (Metamax3b). The findings showed that there is no significant difference between the Cw measured by Metamax3b and the Cw estimates regardless of the modalities used to measure Sfree (Fvalue = 0.02; pvalue = 0.99). The mean bias between Cw measured by the Metamax3b and those estimated using the different Sfree measurement modalities was less than 2.5 % of the mean Cw value. Test retest reliability was excellent with an intraclass correlation coefficient higher than 0.95. in stroke survivors who are able to walk independently without human aid, the use of a 10-m walking test, a 6-minute walking test or a GaitRite recording can be considered validated for estimating Cw.</description><identifier>ISSN: 0966-6362</identifier><identifier>EISSN: 1879-2219</identifier><identifier>DOI: 10.1016/j.gaitpost.2021.07.017</identifier><identifier>PMID: 34358758</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Energy cost ; Energy expenditure ; Gait ; Humans ; Life Sciences ; Oxygen ; Oxygen cost ; Reproducibility of Results ; Stroke ; Walk Test ; Walking</subject><ispartof>Gait &amp; posture, 2021-09, Vol.89, p.217-219</ispartof><rights>2021 Elsevier B.V.</rights><rights>Attribution - NonCommercial</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c427t-35906bf835e1629584870e08eaaa9f01640efd24e90408c5636a462ad1caba23</citedby><cites>FETCH-LOGICAL-c427t-35906bf835e1629584870e08eaaa9f01640efd24e90408c5636a462ad1caba23</cites><orcidid>0000-0001-6915-2094 ; 0000-0002-0188-8043</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://hal.science/hal-03517308$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Compagnat, Maxence</creatorcontrib><creatorcontrib>Mandigout, Stéphane</creatorcontrib><creatorcontrib>Perrochon, Anaick</creatorcontrib><creatorcontrib>Salle, Jean Yves</creatorcontrib><creatorcontrib>Daviet, Jean Christophe</creatorcontrib><title>Which method should be chosen to estimate the oxygen cost of walking in post-stroke individuals?</title><title>Gait &amp; posture</title><description>•Oxygen cost provides access to the energy expenditure of walking in stroke individuals.•Oxygen cost can be estimated regardless of the method used to measure walking speed.•Estimation of the oxygen cost by gait speed has a good test retest reliability. The oxygen cost of walking (Cw) represents the energy expenditure involved in walking, which is a major concern when quantifying physical activity in stroke. Recent studies have reported that Cw may be estimated accurately with a prediction equation using the self-self-selected walking speed (Sfree). To evaluate the validity of Cw estimates according to different modalities of Sfree measurements (10-m walking test, 6-minute walking test, GaitRite system). Twenty-one stroke individuals in subacute phase who were able to walk without human aid were included. Cw was estimated from the walking speed measured during a 10-m walking test, a 6-minute walking test and a recording on a GaitRite system. The values of the Cw estimates were compared to those measured by a respiratory gas exchange analyzer (Metamax3b). The findings showed that there is no significant difference between the Cw measured by Metamax3b and the Cw estimates regardless of the modalities used to measure Sfree (Fvalue = 0.02; pvalue = 0.99). The mean bias between Cw measured by the Metamax3b and those estimated using the different Sfree measurement modalities was less than 2.5 % of the mean Cw value. Test retest reliability was excellent with an intraclass correlation coefficient higher than 0.95. in stroke survivors who are able to walk independently without human aid, the use of a 10-m walking test, a 6-minute walking test or a GaitRite recording can be considered validated for estimating Cw.</description><subject>Energy cost</subject><subject>Energy expenditure</subject><subject>Gait</subject><subject>Humans</subject><subject>Life Sciences</subject><subject>Oxygen</subject><subject>Oxygen cost</subject><subject>Reproducibility of Results</subject><subject>Stroke</subject><subject>Walk Test</subject><subject>Walking</subject><issn>0966-6362</issn><issn>1879-2219</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqFUU1vEzEUtBCIpoW_gHwsh90-f673VKoKKFIkLpU4Gsf7Nut0s07XTqD_HkdpufY0eqN5895oCPnEoGbA9NWmXruQdzHlmgNnNTQ1sOYNWTDTtBXnrH1LFtBqXWmh-Rk5T2kDAFIY_p6cCSmUaZRZkN-_huAHusU8xI6mIe7Hjq6Q-iEmnGiOFFMOW5eR5gFp_Pu0LrQvd2ns6R83PoRpTcNEj69UKc_xAcvYhUPo9m5M1x_Iu74gfnzGC3L_7ev97V21_Pn9x-3NsvKSN7kSqgW96o1QyDRvlZGmAQSDzrm2L4klYN9xiS1IMF6VVE5q7jrm3cpxcUE-n2wHN9rdXD6en2x0wd7dLO2RA6FYI8AcWNFenrS7OT7uSz67DcnjOLoJ4z5ZrlQrudJMFqk-Sf0cU5qx_-_NwB6LsBv7UoQ9FmGhsaWIsvjltIgl8yHgbJMPOHnswow-2y6G1yz-AX6Xkvs</recordid><startdate>202109</startdate><enddate>202109</enddate><creator>Compagnat, Maxence</creator><creator>Mandigout, Stéphane</creator><creator>Perrochon, Anaick</creator><creator>Salle, Jean Yves</creator><creator>Daviet, Jean Christophe</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0001-6915-2094</orcidid><orcidid>https://orcid.org/0000-0002-0188-8043</orcidid></search><sort><creationdate>202109</creationdate><title>Which method should be chosen to estimate the oxygen cost of walking in post-stroke individuals?</title><author>Compagnat, Maxence ; Mandigout, Stéphane ; Perrochon, Anaick ; Salle, Jean Yves ; Daviet, Jean Christophe</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c427t-35906bf835e1629584870e08eaaa9f01640efd24e90408c5636a462ad1caba23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Energy cost</topic><topic>Energy expenditure</topic><topic>Gait</topic><topic>Humans</topic><topic>Life Sciences</topic><topic>Oxygen</topic><topic>Oxygen cost</topic><topic>Reproducibility of Results</topic><topic>Stroke</topic><topic>Walk Test</topic><topic>Walking</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Compagnat, Maxence</creatorcontrib><creatorcontrib>Mandigout, Stéphane</creatorcontrib><creatorcontrib>Perrochon, Anaick</creatorcontrib><creatorcontrib>Salle, Jean Yves</creatorcontrib><creatorcontrib>Daviet, Jean Christophe</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Gait &amp; posture</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Compagnat, Maxence</au><au>Mandigout, Stéphane</au><au>Perrochon, Anaick</au><au>Salle, Jean Yves</au><au>Daviet, Jean Christophe</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Which method should be chosen to estimate the oxygen cost of walking in post-stroke individuals?</atitle><jtitle>Gait &amp; posture</jtitle><date>2021-09</date><risdate>2021</risdate><volume>89</volume><spage>217</spage><epage>219</epage><pages>217-219</pages><issn>0966-6362</issn><eissn>1879-2219</eissn><abstract>•Oxygen cost provides access to the energy expenditure of walking in stroke individuals.•Oxygen cost can be estimated regardless of the method used to measure walking speed.•Estimation of the oxygen cost by gait speed has a good test retest reliability. The oxygen cost of walking (Cw) represents the energy expenditure involved in walking, which is a major concern when quantifying physical activity in stroke. Recent studies have reported that Cw may be estimated accurately with a prediction equation using the self-self-selected walking speed (Sfree). To evaluate the validity of Cw estimates according to different modalities of Sfree measurements (10-m walking test, 6-minute walking test, GaitRite system). Twenty-one stroke individuals in subacute phase who were able to walk without human aid were included. Cw was estimated from the walking speed measured during a 10-m walking test, a 6-minute walking test and a recording on a GaitRite system. The values of the Cw estimates were compared to those measured by a respiratory gas exchange analyzer (Metamax3b). The findings showed that there is no significant difference between the Cw measured by Metamax3b and the Cw estimates regardless of the modalities used to measure Sfree (Fvalue = 0.02; pvalue = 0.99). The mean bias between Cw measured by the Metamax3b and those estimated using the different Sfree measurement modalities was less than 2.5 % of the mean Cw value. Test retest reliability was excellent with an intraclass correlation coefficient higher than 0.95. in stroke survivors who are able to walk independently without human aid, the use of a 10-m walking test, a 6-minute walking test or a GaitRite recording can be considered validated for estimating Cw.</abstract><pub>Elsevier B.V</pub><pmid>34358758</pmid><doi>10.1016/j.gaitpost.2021.07.017</doi><tpages>3</tpages><orcidid>https://orcid.org/0000-0001-6915-2094</orcidid><orcidid>https://orcid.org/0000-0002-0188-8043</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0966-6362
ispartof Gait & posture, 2021-09, Vol.89, p.217-219
issn 0966-6362
1879-2219
language eng
recordid cdi_hal_primary_oai_HAL_hal_03517308v1
source ScienceDirect Freedom Collection
subjects Energy cost
Energy expenditure
Gait
Humans
Life Sciences
Oxygen
Oxygen cost
Reproducibility of Results
Stroke
Walk Test
Walking
title Which method should be chosen to estimate the oxygen cost of walking in post-stroke individuals?
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T23%3A44%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Which%20method%20should%20be%20chosen%20to%20estimate%20the%20oxygen%20cost%20of%20walking%20in%20post-stroke%20individuals?&rft.jtitle=Gait%20&%20posture&rft.au=Compagnat,%20Maxence&rft.date=2021-09&rft.volume=89&rft.spage=217&rft.epage=219&rft.pages=217-219&rft.issn=0966-6362&rft.eissn=1879-2219&rft_id=info:doi/10.1016/j.gaitpost.2021.07.017&rft_dat=%3Cproquest_hal_p%3E2559425614%3C/proquest_hal_p%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c427t-35906bf835e1629584870e08eaaa9f01640efd24e90408c5636a462ad1caba23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2559425614&rft_id=info:pmid/34358758&rfr_iscdi=true