Loading…

Articular Noise After THA Using Delta CoC Bearings Has Little Impact on Quality of Life

To report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL). From...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of arthroplasty 2021-05, Vol.36 (5), p.1678-1687
Main Authors: Chatelet, Jean-Christophe, Fessy, Michel-Henri, Saffarini, Mo, Machenaud, Alain, Rollier, Jean-Charles, Setiey, Louis, Chouteau, Julien, Bonnin, Michel P., Vidalain, Jean-Pierre, Jacquot, Laurent
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL). From a series of 456 CoC THAs, there were 25 revisions, 38 deceased, and 36 lost to follow-up. The remaining 357 hips were assessed at 11.1 ± 0.7 years (range, 10-14) using the Forgotten Joint Score, Oxford Hip Score, and a questionnaire on articular noises. Kaplan-Meier survival was calculated, and multivariable analysis was performed to determine associations between articular noise and patient/surgical factors. The 10-year survival was 96.3% for the cup, 96.5% for the stem, and 94.2% for all components. The Forgotten Joint Score was 79 ± 26 (range, 0-100), and Oxford Hip Score was 16 ± 7 (range, 12-60). The mean impact of articular noises on QoL was 1.8 ± 2.9 (range, 0-9): considered negligible in 60 hips (16%), moderate in 27 hips (7%), and severe in only 13 hips (4%). Multivariable analyses revealed that the incidence of articular noise decreased with age (odds ratio [OR], 0.94; P = .001), body mass index (OR, 0.85; P = .001), and in hips implanted with 32-mm (vs 36 mm) heads (OR, 0.18; P = .030). Of 100 hips (28%) that reported some articular noises 10 years after CoC THA, the impact of articular noises on QoL was negligible for most patients. Although larger heads can improve mobility and reduce risks of dislocations, surgeons must be aware that increasing head size could also increase risks of articular noises, notably in young and active patients.
ISSN:0883-5403
1532-8406
DOI:10.1016/j.arth.2020.11.012