Loading…

High-accuracy mass determination of unstable cesium and barium isotopes

Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of δm ≈ 13 keV have been obtained. The masses...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear physics. A 1999-05, Vol.651 (1), p.3-30
Main Authors: Ames, F., Audi, G., Beck, D., Bollen, G., de Saint Simon, M., Jertz, R., Kluge, H.-J., Kohl, A., König, M., Lunney, D., Martel, I., Moore, R.B., Otto, T., Patyk, Z., Raimbault-Hartmann, H., Rouleau, G., Savard, G., Schark, E., Schwarz, S., Schweikhard, L., Stolzenberg, H., Szerypo, J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c425t-3a8dee96839caa84640f2b4f18b6c6c433874fda34d87fee6acea6375bbedbde3
cites cdi_FETCH-LOGICAL-c425t-3a8dee96839caa84640f2b4f18b6c6c433874fda34d87fee6acea6375bbedbde3
container_end_page 30
container_issue 1
container_start_page 3
container_title Nuclear physics. A
container_volume 651
creator Ames, F.
Audi, G.
Beck, D.
Bollen, G.
de Saint Simon, M.
Jertz, R.
Kluge, H.-J.
Kohl, A.
König, M.
Lunney, D.
Martel, I.
Moore, R.B.
Otto, T.
Patyk, Z.
Raimbault-Hartmann, H.
Rouleau, G.
Savard, G.
Schark, E.
Schwarz, S.
Schweikhard, L.
Stolzenberg, H.
Szerypo, J.
description Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of δm ≈ 13 keV have been obtained. The masses of 123,124,126Ba and 122 m Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.
doi_str_mv 10.1016/S0375-9474(99)00111-6
format article
fullrecord <record><control><sourceid>elsevier_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_in2p3_00013288v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0375947499001116</els_id><sourcerecordid>S0375947499001116</sourcerecordid><originalsourceid>FETCH-LOGICAL-c425t-3a8dee96839caa84640f2b4f18b6c6c433874fda34d87fee6acea6375bbedbde3</originalsourceid><addsrcrecordid>eNqFkEFLAzEQhYMoWKs_QdijIqvJJpvNnqQUbYWCB_UcJsnERrq7JdkW-u_dttKrc5k5vPeY9xFyy-gjo0w-fVBelXktKnFX1_eUMsZyeUZGTFU8Z2UpzsnoJLkkVyn90GEkpSMym4fvZQ7WbiLYXdZASpnDHmMTWuhD12adzzZt6sGsMLOYwqbJoHWZgbg_Q-r6bo3pmlx4WCW8-dtj8vX68jmd54v32dt0ssitKMo-56AcYi0Vry2AElJQXxjhmTLSSis4V5XwDrhwqvKIEiyCHH43Bp1xyMfk4Zi7hJVex9BA3OkOgp5PFjq0xZrroRrjhVJbNqjLo9rGLqWI_mRhVO_Z6QM7vQej61of2Gk5-J6PPhyqbANGnWzA1qILEW2vXRf-SfgFyhB3CQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>High-accuracy mass determination of unstable cesium and barium isotopes</title><source>Elsevier:Jisc Collections:Elsevier Read and Publish Agreement 2022-2024:Freedom Collection (Reading list)</source><creator>Ames, F. ; Audi, G. ; Beck, D. ; Bollen, G. ; de Saint Simon, M. ; Jertz, R. ; Kluge, H.-J. ; Kohl, A. ; König, M. ; Lunney, D. ; Martel, I. ; Moore, R.B. ; Otto, T. ; Patyk, Z. ; Raimbault-Hartmann, H. ; Rouleau, G. ; Savard, G. ; Schark, E. ; Schwarz, S. ; Schweikhard, L. ; Stolzenberg, H. ; Szerypo, J.</creator><creatorcontrib>Ames, F. ; Audi, G. ; Beck, D. ; Bollen, G. ; de Saint Simon, M. ; Jertz, R. ; Kluge, H.-J. ; Kohl, A. ; König, M. ; Lunney, D. ; Martel, I. ; Moore, R.B. ; Otto, T. ; Patyk, Z. ; Raimbault-Hartmann, H. ; Rouleau, G. ; Savard, G. ; Schark, E. ; Schwarz, S. ; Schweikhard, L. ; Stolzenberg, H. ; Szerypo, J. ; ; The ISOLDE Collaboration</creatorcontrib><description>Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of δm ≈ 13 keV have been obtained. The masses of 123,124,126Ba and 122 m Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.</description><identifier>ISSN: 0375-9474</identifier><identifier>EISSN: 1873-1554</identifier><identifier>DOI: 10.1016/S0375-9474(99)00111-6</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Atomic masses ; Nuclear Experiment ; Physics</subject><ispartof>Nuclear physics. A, 1999-05, Vol.651 (1), p.3-30</ispartof><rights>1999</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c425t-3a8dee96839caa84640f2b4f18b6c6c433874fda34d87fee6acea6375bbedbde3</citedby><cites>FETCH-LOGICAL-c425t-3a8dee96839caa84640f2b4f18b6c6c433874fda34d87fee6acea6375bbedbde3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://in2p3.hal.science/in2p3-00013288$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Ames, F.</creatorcontrib><creatorcontrib>Audi, G.</creatorcontrib><creatorcontrib>Beck, D.</creatorcontrib><creatorcontrib>Bollen, G.</creatorcontrib><creatorcontrib>de Saint Simon, M.</creatorcontrib><creatorcontrib>Jertz, R.</creatorcontrib><creatorcontrib>Kluge, H.-J.</creatorcontrib><creatorcontrib>Kohl, A.</creatorcontrib><creatorcontrib>König, M.</creatorcontrib><creatorcontrib>Lunney, D.</creatorcontrib><creatorcontrib>Martel, I.</creatorcontrib><creatorcontrib>Moore, R.B.</creatorcontrib><creatorcontrib>Otto, T.</creatorcontrib><creatorcontrib>Patyk, Z.</creatorcontrib><creatorcontrib>Raimbault-Hartmann, H.</creatorcontrib><creatorcontrib>Rouleau, G.</creatorcontrib><creatorcontrib>Savard, G.</creatorcontrib><creatorcontrib>Schark, E.</creatorcontrib><creatorcontrib>Schwarz, S.</creatorcontrib><creatorcontrib>Schweikhard, L.</creatorcontrib><creatorcontrib>Stolzenberg, H.</creatorcontrib><creatorcontrib>Szerypo, J.</creatorcontrib><creatorcontrib>The ISOLDE Collaboration</creatorcontrib><title>High-accuracy mass determination of unstable cesium and barium isotopes</title><title>Nuclear physics. A</title><description>Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of δm ≈ 13 keV have been obtained. The masses of 123,124,126Ba and 122 m Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.</description><subject>Atomic masses</subject><subject>Nuclear Experiment</subject><subject>Physics</subject><issn>0375-9474</issn><issn>1873-1554</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqFkEFLAzEQhYMoWKs_QdijIqvJJpvNnqQUbYWCB_UcJsnERrq7JdkW-u_dttKrc5k5vPeY9xFyy-gjo0w-fVBelXktKnFX1_eUMsZyeUZGTFU8Z2UpzsnoJLkkVyn90GEkpSMym4fvZQ7WbiLYXdZASpnDHmMTWuhD12adzzZt6sGsMLOYwqbJoHWZgbg_Q-r6bo3pmlx4WCW8-dtj8vX68jmd54v32dt0ssitKMo-56AcYi0Vry2AElJQXxjhmTLSSis4V5XwDrhwqvKIEiyCHH43Bp1xyMfk4Zi7hJVex9BA3OkOgp5PFjq0xZrroRrjhVJbNqjLo9rGLqWI_mRhVO_Z6QM7vQej61of2Gk5-J6PPhyqbANGnWzA1qILEW2vXRf-SfgFyhB3CQ</recordid><startdate>19990503</startdate><enddate>19990503</enddate><creator>Ames, F.</creator><creator>Audi, G.</creator><creator>Beck, D.</creator><creator>Bollen, G.</creator><creator>de Saint Simon, M.</creator><creator>Jertz, R.</creator><creator>Kluge, H.-J.</creator><creator>Kohl, A.</creator><creator>König, M.</creator><creator>Lunney, D.</creator><creator>Martel, I.</creator><creator>Moore, R.B.</creator><creator>Otto, T.</creator><creator>Patyk, Z.</creator><creator>Raimbault-Hartmann, H.</creator><creator>Rouleau, G.</creator><creator>Savard, G.</creator><creator>Schark, E.</creator><creator>Schwarz, S.</creator><creator>Schweikhard, L.</creator><creator>Stolzenberg, H.</creator><creator>Szerypo, J.</creator><general>Elsevier B.V</general><general>North-Holland ; Elsevier [1967-....]</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope></search><sort><creationdate>19990503</creationdate><title>High-accuracy mass determination of unstable cesium and barium isotopes</title><author>Ames, F. ; Audi, G. ; Beck, D. ; Bollen, G. ; de Saint Simon, M. ; Jertz, R. ; Kluge, H.-J. ; Kohl, A. ; König, M. ; Lunney, D. ; Martel, I. ; Moore, R.B. ; Otto, T. ; Patyk, Z. ; Raimbault-Hartmann, H. ; Rouleau, G. ; Savard, G. ; Schark, E. ; Schwarz, S. ; Schweikhard, L. ; Stolzenberg, H. ; Szerypo, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c425t-3a8dee96839caa84640f2b4f18b6c6c433874fda34d87fee6acea6375bbedbde3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Atomic masses</topic><topic>Nuclear Experiment</topic><topic>Physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ames, F.</creatorcontrib><creatorcontrib>Audi, G.</creatorcontrib><creatorcontrib>Beck, D.</creatorcontrib><creatorcontrib>Bollen, G.</creatorcontrib><creatorcontrib>de Saint Simon, M.</creatorcontrib><creatorcontrib>Jertz, R.</creatorcontrib><creatorcontrib>Kluge, H.-J.</creatorcontrib><creatorcontrib>Kohl, A.</creatorcontrib><creatorcontrib>König, M.</creatorcontrib><creatorcontrib>Lunney, D.</creatorcontrib><creatorcontrib>Martel, I.</creatorcontrib><creatorcontrib>Moore, R.B.</creatorcontrib><creatorcontrib>Otto, T.</creatorcontrib><creatorcontrib>Patyk, Z.</creatorcontrib><creatorcontrib>Raimbault-Hartmann, H.</creatorcontrib><creatorcontrib>Rouleau, G.</creatorcontrib><creatorcontrib>Savard, G.</creatorcontrib><creatorcontrib>Schark, E.</creatorcontrib><creatorcontrib>Schwarz, S.</creatorcontrib><creatorcontrib>Schweikhard, L.</creatorcontrib><creatorcontrib>Stolzenberg, H.</creatorcontrib><creatorcontrib>Szerypo, J.</creatorcontrib><creatorcontrib>The ISOLDE Collaboration</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Nuclear physics. A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ames, F.</au><au>Audi, G.</au><au>Beck, D.</au><au>Bollen, G.</au><au>de Saint Simon, M.</au><au>Jertz, R.</au><au>Kluge, H.-J.</au><au>Kohl, A.</au><au>König, M.</au><au>Lunney, D.</au><au>Martel, I.</au><au>Moore, R.B.</au><au>Otto, T.</au><au>Patyk, Z.</au><au>Raimbault-Hartmann, H.</au><au>Rouleau, G.</au><au>Savard, G.</au><au>Schark, E.</au><au>Schwarz, S.</au><au>Schweikhard, L.</au><au>Stolzenberg, H.</au><au>Szerypo, J.</au><aucorp>The ISOLDE Collaboration</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High-accuracy mass determination of unstable cesium and barium isotopes</atitle><jtitle>Nuclear physics. A</jtitle><date>1999-05-03</date><risdate>1999</risdate><volume>651</volume><issue>1</issue><spage>3</spage><epage>30</epage><pages>3-30</pages><issn>0375-9474</issn><eissn>1873-1554</eissn><abstract>Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of δm ≈ 13 keV have been obtained. The masses of 123,124,126Ba and 122 m Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0375-9474(99)00111-6</doi><tpages>28</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0375-9474
ispartof Nuclear physics. A, 1999-05, Vol.651 (1), p.3-30
issn 0375-9474
1873-1554
language eng
recordid cdi_hal_primary_oai_HAL_in2p3_00013288v1
source Elsevier:Jisc Collections:Elsevier Read and Publish Agreement 2022-2024:Freedom Collection (Reading list)
subjects Atomic masses
Nuclear Experiment
Physics
title High-accuracy mass determination of unstable cesium and barium isotopes
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T02%3A51%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High-accuracy%20mass%20determination%20of%20unstable%20cesium%20and%20barium%20isotopes&rft.jtitle=Nuclear%20physics.%20A&rft.au=Ames,%20F.&rft.aucorp=The%20ISOLDE%20Collaboration&rft.date=1999-05-03&rft.volume=651&rft.issue=1&rft.spage=3&rft.epage=30&rft.pages=3-30&rft.issn=0375-9474&rft.eissn=1873-1554&rft_id=info:doi/10.1016/S0375-9474(99)00111-6&rft_dat=%3Celsevier_hal_p%3ES0375947499001116%3C/elsevier_hal_p%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c425t-3a8dee96839caa84640f2b4f18b6c6c433874fda34d87fee6acea6375bbedbde3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true