Loading…

Influence of short-lived radioiodines other than 131I on screening direct thyroid measurements with TCS-172 NAI(TL) survey meters

Abstract In a nuclear emergency, one of the actions taken for the sake of public is to monitor thyroid exposure to radioiodines. Japan’s Nuclear Regulation Authority recently published a report on such monitoring and proposed direct thyroid measurements with conventional NaI(Tl) survey meters (e.g....

Full description

Saved in:
Bibliographic Details
Published in:Radiation protection dosimetry 2024-03, Vol.200 (3), p.315-321
Main Authors: Tani, Kotaro, Kim, Eunjoo, Yajima, Kazuaki, Naito, Masayuki, Ishigure, Nobuhito, Beaumont, Tiffany, Broggio, David, Kurihara, Osamu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract In a nuclear emergency, one of the actions taken for the sake of public is to monitor thyroid exposure to radioiodines. Japan’s Nuclear Regulation Authority recently published a report on such monitoring and proposed direct thyroid measurements with conventional NaI(Tl) survey meters (e.g. Hitachi model TCS-172) as a primary screening method. A previous study proposed screening levels (SLs) used in these simplified measurements as the net reading values of the TCS-172 device. Age-specific SLs were derived from a thyroid equivalent dose of 100 mSv due to the inhalation intake of 131I. This study addressed the possible influence of short-lived iodine isotopes other than 131I on the simplified measurements. In preparation for such measurements, the responses of the device for 132I as an ingrowth component from 132Te, 133I, 134I and 135I in the thyroid were evaluated by numerical simulations using age-specific stylized phantoms in addition to those obtained for 131I in the previous study. The radioactivity ratios of the relevant isotopes were taken from the inventory data of the Fukushima Daiichi Nuclear Power Plant. The results were used to predict the net readings of the device when 132Te-132I and 133I as well as 131I were inhaled at 24 or 72 h after the shutdown of a nuclear power plant. In these cases, the signals from 132Te-132I and 133I become undetectable a couple of days after intake, which could lead to underestimations of the thyroid dose. To estimate the thyroid dose accurately from the simplified measurements, it is necessary to identify the exact time of intake after the shutdown and the actual physiochemical property of 132Te that affects the thyroid uptake of 132I.
ISSN:0144-8420
1742-3406
DOI:10.1093/rpd/ncad304