Loading…

Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode

Anodic stripping voltammetry (ASV) with rotating glassy carbon electrode (RGCE) and microfiber carbon electrode (µFCE), both filmed with mercury, were used to determine copper content in wine. Influence of phenolics on in situ mercury film formation was studied. Wine and quercetin were added gradual...

Full description

Saved in:
Bibliographic Details
Published in:Croatica Chemica Acta 2017, Vol.90 (2), p.353
Main Authors: Sužnjević, Desanka Ž., Pastor, Ferenc T., Gorjanović, Stanislava Ž.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c296t-aa0fd0a8f5391977cc924836546dbe3456e0c49e730e95ebd98e0ee4e589b5133
cites
container_end_page
container_issue 2
container_start_page 353
container_title Croatica Chemica Acta
container_volume 90
creator Sužnjević, Desanka Ž.
Pastor, Ferenc T.
Gorjanović, Stanislava Ž.
description Anodic stripping voltammetry (ASV) with rotating glassy carbon electrode (RGCE) and microfiber carbon electrode (µFCE), both filmed with mercury, were used to determine copper content in wine. Influence of phenolics on in situ mercury film formation was studied. Wine and quercetin were added gradually into solution of Hg(II) in acetic acid-sodium acetate buffer (pH = 4.60). Reduction of Hg(II) was observed in both cases. In situ filmed electrode was found unsuitable. Results obtained using ex situ filmed RGCE and µFCE were found in good agreement with ASV using hanging mercury drop electrode. Thus, ASV with ex situ mercury filmed electrodes can be recommended for accurate quantification of copper in complex samples containing phenolics, without any special pretreatments. This work is licensed under a Creative Commons Attribution 4.0 International License .
doi_str_mv 10.5562/cca3178
format article
fullrecord <record><control><sourceid>crossref_hrcak</sourceid><recordid>TN_cdi_hrcak_primary_oai_hrcak_srce_hr_187855</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_5562_cca3178</sourcerecordid><originalsourceid>FETCH-LOGICAL-c296t-aa0fd0a8f5391977cc924836546dbe3456e0c49e730e95ebd98e0ee4e589b5133</originalsourceid><addsrcrecordid>eNo9kE9LxDAQxYMouK7iV8jNUzVpkjY5LnVdhRXB_7eSplM32m1KEpDilzeyi6cZ3rz3GH4InVNyKUSRXxmjGS3lAZpRxnjGafl-iGaEUJrRgrNjdBLCJyG54ELO0M81RPBbO-ho3YBdhys3juCxHfCbHQA3E14MrrUGP0Vvx9EOH_jV9VFvtxD9hL9t3OBHF1M-XVa9DmHClfZNatNDi--t8a6zTarcq8seTPSuhVN01Ok-wNl-ztHLzfK5us3WD6u7arHOTK6KmGlNupZo2QmmqCpLY1TOJSsEL9oGGBcFEMMVlIyAEtC0SgIB4CCkakSCMEfZrnfjjf6qR2-32k-107beKcEbSGtNZSmFSP6LnT99HoKH7j9CSf3HuN4zZr9wmXEk</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode</title><source>Publicly Available Content Database</source><creator>Sužnjević, Desanka Ž. ; Pastor, Ferenc T. ; Gorjanović, Stanislava Ž.</creator><creatorcontrib>Sužnjević, Desanka Ž. ; Pastor, Ferenc T. ; Gorjanović, Stanislava Ž.</creatorcontrib><description>Anodic stripping voltammetry (ASV) with rotating glassy carbon electrode (RGCE) and microfiber carbon electrode (µFCE), both filmed with mercury, were used to determine copper content in wine. Influence of phenolics on in situ mercury film formation was studied. Wine and quercetin were added gradually into solution of Hg(II) in acetic acid-sodium acetate buffer (pH = 4.60). Reduction of Hg(II) was observed in both cases. In situ filmed electrode was found unsuitable. Results obtained using ex situ filmed RGCE and µFCE were found in good agreement with ASV using hanging mercury drop electrode. Thus, ASV with ex situ mercury filmed electrodes can be recommended for accurate quantification of copper in complex samples containing phenolics, without any special pretreatments. This work is licensed under a Creative Commons Attribution 4.0 International License .</description><identifier>ISSN: 0011-1643</identifier><identifier>EISSN: 1334-417X</identifier><identifier>DOI: 10.5562/cca3178</identifier><identifier>CODEN: CCACAA</identifier><language>eng</language><publisher>Hrvatsko kemijsko društvo</publisher><subject>anodic stripping voltammetry ; carbon microfiber electrode ; copper ; glassy carbon electrode ; mercury film electrode ; wine</subject><ispartof>Croatica Chemica Acta, 2017, Vol.90 (2), p.353</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c296t-aa0fd0a8f5391977cc924836546dbe3456e0c49e730e95ebd98e0ee4e589b5133</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://hrcak.srce.hr/logo_broj/14850.jpg</thumbnail><link.rule.ids>230,314,780,784,885,4023,27922,27923,27924</link.rule.ids></links><search><creatorcontrib>Sužnjević, Desanka Ž.</creatorcontrib><creatorcontrib>Pastor, Ferenc T.</creatorcontrib><creatorcontrib>Gorjanović, Stanislava Ž.</creatorcontrib><title>Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode</title><title>Croatica Chemica Acta</title><description>Anodic stripping voltammetry (ASV) with rotating glassy carbon electrode (RGCE) and microfiber carbon electrode (µFCE), both filmed with mercury, were used to determine copper content in wine. Influence of phenolics on in situ mercury film formation was studied. Wine and quercetin were added gradually into solution of Hg(II) in acetic acid-sodium acetate buffer (pH = 4.60). Reduction of Hg(II) was observed in both cases. In situ filmed electrode was found unsuitable. Results obtained using ex situ filmed RGCE and µFCE were found in good agreement with ASV using hanging mercury drop electrode. Thus, ASV with ex situ mercury filmed electrodes can be recommended for accurate quantification of copper in complex samples containing phenolics, without any special pretreatments. This work is licensed under a Creative Commons Attribution 4.0 International License .</description><subject>anodic stripping voltammetry</subject><subject>carbon microfiber electrode</subject><subject>copper</subject><subject>glassy carbon electrode</subject><subject>mercury film electrode</subject><subject>wine</subject><issn>0011-1643</issn><issn>1334-417X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNo9kE9LxDAQxYMouK7iV8jNUzVpkjY5LnVdhRXB_7eSplM32m1KEpDilzeyi6cZ3rz3GH4InVNyKUSRXxmjGS3lAZpRxnjGafl-iGaEUJrRgrNjdBLCJyG54ELO0M81RPBbO-ho3YBdhys3juCxHfCbHQA3E14MrrUGP0Vvx9EOH_jV9VFvtxD9hL9t3OBHF1M-XVa9DmHClfZNatNDi--t8a6zTarcq8seTPSuhVN01Ok-wNl-ztHLzfK5us3WD6u7arHOTK6KmGlNupZo2QmmqCpLY1TOJSsEL9oGGBcFEMMVlIyAEtC0SgIB4CCkakSCMEfZrnfjjf6qR2-32k-107beKcEbSGtNZSmFSP6LnT99HoKH7j9CSf3HuN4zZr9wmXEk</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Sužnjević, Desanka Ž.</creator><creator>Pastor, Ferenc T.</creator><creator>Gorjanović, Stanislava Ž.</creator><general>Hrvatsko kemijsko društvo</general><scope>AAYXX</scope><scope>CITATION</scope><scope>VP8</scope></search><sort><creationdate>2017</creationdate><title>Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode</title><author>Sužnjević, Desanka Ž. ; Pastor, Ferenc T. ; Gorjanović, Stanislava Ž.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c296t-aa0fd0a8f5391977cc924836546dbe3456e0c49e730e95ebd98e0ee4e589b5133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>anodic stripping voltammetry</topic><topic>carbon microfiber electrode</topic><topic>copper</topic><topic>glassy carbon electrode</topic><topic>mercury film electrode</topic><topic>wine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sužnjević, Desanka Ž.</creatorcontrib><creatorcontrib>Pastor, Ferenc T.</creatorcontrib><creatorcontrib>Gorjanović, Stanislava Ž.</creatorcontrib><collection>CrossRef</collection><collection>Hrcak: Portal of scientific journals of Croatia</collection><jtitle>Croatica Chemica Acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sužnjević, Desanka Ž.</au><au>Pastor, Ferenc T.</au><au>Gorjanović, Stanislava Ž.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode</atitle><jtitle>Croatica Chemica Acta</jtitle><date>2017</date><risdate>2017</risdate><volume>90</volume><issue>2</issue><spage>353</spage><pages>353-</pages><issn>0011-1643</issn><eissn>1334-417X</eissn><coden>CCACAA</coden><abstract>Anodic stripping voltammetry (ASV) with rotating glassy carbon electrode (RGCE) and microfiber carbon electrode (µFCE), both filmed with mercury, were used to determine copper content in wine. Influence of phenolics on in situ mercury film formation was studied. Wine and quercetin were added gradually into solution of Hg(II) in acetic acid-sodium acetate buffer (pH = 4.60). Reduction of Hg(II) was observed in both cases. In situ filmed electrode was found unsuitable. Results obtained using ex situ filmed RGCE and µFCE were found in good agreement with ASV using hanging mercury drop electrode. Thus, ASV with ex situ mercury filmed electrodes can be recommended for accurate quantification of copper in complex samples containing phenolics, without any special pretreatments. This work is licensed under a Creative Commons Attribution 4.0 International License .</abstract><pub>Hrvatsko kemijsko društvo</pub><doi>10.5562/cca3178</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0011-1643
ispartof Croatica Chemica Acta, 2017, Vol.90 (2), p.353
issn 0011-1643
1334-417X
language eng
recordid cdi_hrcak_primary_oai_hrcak_srce_hr_187855
source Publicly Available Content Database
subjects anodic stripping voltammetry
carbon microfiber electrode
copper
glassy carbon electrode
mercury film electrode
wine
title Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T06%3A31%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_hrcak&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Copper%20in%20Wine%20by%20Anodic%20Stripping%20Voltammetry%20with%20Rotating%20Glassy%20Carbon%20and%20Microfiber%20Carbon%20Electrode&rft.jtitle=Croatica%20Chemica%20Acta&rft.au=Su%C5%BEnjevi%C4%87,%20Desanka%20%C5%BD.&rft.date=2017&rft.volume=90&rft.issue=2&rft.spage=353&rft.pages=353-&rft.issn=0011-1643&rft.eissn=1334-417X&rft.coden=CCACAA&rft_id=info:doi/10.5562/cca3178&rft_dat=%3Ccrossref_hrcak%3E10_5562_cca3178%3C/crossref_hrcak%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c296t-aa0fd0a8f5391977cc924836546dbe3456e0c49e730e95ebd98e0ee4e589b5133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true