Loading…

A New Strategy for Detection and Management of Faults in High Power NPC Converter Systems

Neutral Point Clamped (NPC) converter is often used in high power medium voltage industrial applications. This paper proposes a new fault detection and management method for NPC converters, able to detect any type of power semiconductor device fault and to allow the continuity of operation in case o...

Full description

Saved in:
Bibliographic Details
Main Authors: Benevieri, Alessandro, Carbone, Lorenzo, Cosso, Simone, Gallione, Flavio, Hussain, Shafquat
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 9
container_issue
container_start_page 1
container_title
container_volume
creator Benevieri, Alessandro
Carbone, Lorenzo
Cosso, Simone
Gallione, Flavio
Hussain, Shafquat
description Neutral Point Clamped (NPC) converter is often used in high power medium voltage industrial applications. This paper proposes a new fault detection and management method for NPC converters, able to detect any type of power semiconductor device fault and to allow the continuity of operation in case of fault. The fault detection, which is very fast, is based on the measurements of load and clamp-diode legs currents. The fault management strategy is suitable for NPC inverters feeding both passive and active load (such as a threephase asynchronous motor) supplied by Active Front End (AFE) or Diode Front End (DFE). Finally, a comparison among three different reconfiguring modulations, with special regard to the evaluation of harmonic distortion of the line-to-line voltages and phase currents, is suggested.
doi_str_mv 10.1109/ATEE58038.2023.10108255
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_10108255</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10108255</ieee_id><sourcerecordid>10108255</sourcerecordid><originalsourceid>FETCH-LOGICAL-i119t-c59a9e946a3df3d2eb754b7d7f0d997f58b0b6cc4e3fe1a7e0788dea610bf42c3</originalsourceid><addsrcrecordid>eNo1kMtOwkAUQEcTEwnyBybeHyje6XQed0kqiAkiCbhwRabtHayB1rSjhL-XRF2dnM1ZHCHuJI6lRLqfbKZT7VC5cYqpGkuU6FKtL8SILDmlUSlJylyKQSo1Jcpgdi1Gff-BiJKIjFED8TaBJR9hHTsfeXeC0HbwwJHLWLcN-KaCZ9_4HR-4idAGmPmvfeyhbmBe795h1R65g-Uqh7xtvrmLZ1uf-siH_kZcBb_vefTHoXidTTf5PFm8PD7lk0VSS0kxKTV5YsqMV1VQVcqF1VlhKxuwIrJBuwILU5YZq8DSW0brXMXeSCxClpZqKG5_uzUzbz-7-uC70_b_hvoBdfhUWA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A New Strategy for Detection and Management of Faults in High Power NPC Converter Systems</title><source>IEEE Xplore All Conference Series</source><creator>Benevieri, Alessandro ; Carbone, Lorenzo ; Cosso, Simone ; Gallione, Flavio ; Hussain, Shafquat</creator><creatorcontrib>Benevieri, Alessandro ; Carbone, Lorenzo ; Cosso, Simone ; Gallione, Flavio ; Hussain, Shafquat</creatorcontrib><description>Neutral Point Clamped (NPC) converter is often used in high power medium voltage industrial applications. This paper proposes a new fault detection and management method for NPC converters, able to detect any type of power semiconductor device fault and to allow the continuity of operation in case of fault. The fault detection, which is very fast, is based on the measurements of load and clamp-diode legs currents. The fault management strategy is suitable for NPC inverters feeding both passive and active load (such as a threephase asynchronous motor) supplied by Active Front End (AFE) or Diode Front End (DFE). Finally, a comparison among three different reconfiguring modulations, with special regard to the evaluation of harmonic distortion of the line-to-line voltages and phase currents, is suggested.</description><identifier>EISSN: 2159-3604</identifier><identifier>EISBN: 9798350331936</identifier><identifier>DOI: 10.1109/ATEE58038.2023.10108255</identifier><language>eng</language><publisher>IEEE</publisher><subject>Costs ; Fault detection ; Fault tolerance ; Fault tolerant systems ; Inverters ; multilevel converter ; NPC converter ; space vector modulation (SVM) ; Support vector machines ; Total harmonic distortion</subject><ispartof>2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE), 2023, p.1-9</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10108255$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10108255$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Benevieri, Alessandro</creatorcontrib><creatorcontrib>Carbone, Lorenzo</creatorcontrib><creatorcontrib>Cosso, Simone</creatorcontrib><creatorcontrib>Gallione, Flavio</creatorcontrib><creatorcontrib>Hussain, Shafquat</creatorcontrib><title>A New Strategy for Detection and Management of Faults in High Power NPC Converter Systems</title><title>2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)</title><addtitle>ATEE</addtitle><description>Neutral Point Clamped (NPC) converter is often used in high power medium voltage industrial applications. This paper proposes a new fault detection and management method for NPC converters, able to detect any type of power semiconductor device fault and to allow the continuity of operation in case of fault. The fault detection, which is very fast, is based on the measurements of load and clamp-diode legs currents. The fault management strategy is suitable for NPC inverters feeding both passive and active load (such as a threephase asynchronous motor) supplied by Active Front End (AFE) or Diode Front End (DFE). Finally, a comparison among three different reconfiguring modulations, with special regard to the evaluation of harmonic distortion of the line-to-line voltages and phase currents, is suggested.</description><subject>Costs</subject><subject>Fault detection</subject><subject>Fault tolerance</subject><subject>Fault tolerant systems</subject><subject>Inverters</subject><subject>multilevel converter</subject><subject>NPC converter</subject><subject>space vector modulation (SVM)</subject><subject>Support vector machines</subject><subject>Total harmonic distortion</subject><issn>2159-3604</issn><isbn>9798350331936</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2023</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo1kMtOwkAUQEcTEwnyBybeHyje6XQed0kqiAkiCbhwRabtHayB1rSjhL-XRF2dnM1ZHCHuJI6lRLqfbKZT7VC5cYqpGkuU6FKtL8SILDmlUSlJylyKQSo1Jcpgdi1Gff-BiJKIjFED8TaBJR9hHTsfeXeC0HbwwJHLWLcN-KaCZ9_4HR-4idAGmPmvfeyhbmBe795h1R65g-Uqh7xtvrmLZ1uf-siH_kZcBb_vefTHoXidTTf5PFm8PD7lk0VSS0kxKTV5YsqMV1VQVcqF1VlhKxuwIrJBuwILU5YZq8DSW0brXMXeSCxClpZqKG5_uzUzbz-7-uC70_b_hvoBdfhUWA</recordid><startdate>20230323</startdate><enddate>20230323</enddate><creator>Benevieri, Alessandro</creator><creator>Carbone, Lorenzo</creator><creator>Cosso, Simone</creator><creator>Gallione, Flavio</creator><creator>Hussain, Shafquat</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>20230323</creationdate><title>A New Strategy for Detection and Management of Faults in High Power NPC Converter Systems</title><author>Benevieri, Alessandro ; Carbone, Lorenzo ; Cosso, Simone ; Gallione, Flavio ; Hussain, Shafquat</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i119t-c59a9e946a3df3d2eb754b7d7f0d997f58b0b6cc4e3fe1a7e0788dea610bf42c3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Costs</topic><topic>Fault detection</topic><topic>Fault tolerance</topic><topic>Fault tolerant systems</topic><topic>Inverters</topic><topic>multilevel converter</topic><topic>NPC converter</topic><topic>space vector modulation (SVM)</topic><topic>Support vector machines</topic><topic>Total harmonic distortion</topic><toplevel>online_resources</toplevel><creatorcontrib>Benevieri, Alessandro</creatorcontrib><creatorcontrib>Carbone, Lorenzo</creatorcontrib><creatorcontrib>Cosso, Simone</creatorcontrib><creatorcontrib>Gallione, Flavio</creatorcontrib><creatorcontrib>Hussain, Shafquat</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Benevieri, Alessandro</au><au>Carbone, Lorenzo</au><au>Cosso, Simone</au><au>Gallione, Flavio</au><au>Hussain, Shafquat</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A New Strategy for Detection and Management of Faults in High Power NPC Converter Systems</atitle><btitle>2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)</btitle><stitle>ATEE</stitle><date>2023-03-23</date><risdate>2023</risdate><spage>1</spage><epage>9</epage><pages>1-9</pages><eissn>2159-3604</eissn><eisbn>9798350331936</eisbn><abstract>Neutral Point Clamped (NPC) converter is often used in high power medium voltage industrial applications. This paper proposes a new fault detection and management method for NPC converters, able to detect any type of power semiconductor device fault and to allow the continuity of operation in case of fault. The fault detection, which is very fast, is based on the measurements of load and clamp-diode legs currents. The fault management strategy is suitable for NPC inverters feeding both passive and active load (such as a threephase asynchronous motor) supplied by Active Front End (AFE) or Diode Front End (DFE). Finally, a comparison among three different reconfiguring modulations, with special regard to the evaluation of harmonic distortion of the line-to-line voltages and phase currents, is suggested.</abstract><pub>IEEE</pub><doi>10.1109/ATEE58038.2023.10108255</doi><tpages>9</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 2159-3604
ispartof 2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE), 2023, p.1-9
issn 2159-3604
language eng
recordid cdi_ieee_primary_10108255
source IEEE Xplore All Conference Series
subjects Costs
Fault detection
Fault tolerance
Fault tolerant systems
Inverters
multilevel converter
NPC converter
space vector modulation (SVM)
Support vector machines
Total harmonic distortion
title A New Strategy for Detection and Management of Faults in High Power NPC Converter Systems
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A21%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20New%20Strategy%20for%20Detection%20and%20Management%20of%20Faults%20in%20High%20Power%20NPC%20Converter%20Systems&rft.btitle=2023%2013th%20International%20Symposium%20on%20Advanced%20Topics%20in%20Electrical%20Engineering%20(ATEE)&rft.au=Benevieri,%20Alessandro&rft.date=2023-03-23&rft.spage=1&rft.epage=9&rft.pages=1-9&rft.eissn=2159-3604&rft_id=info:doi/10.1109/ATEE58038.2023.10108255&rft.eisbn=9798350331936&rft_dat=%3Cieee_CHZPO%3E10108255%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i119t-c59a9e946a3df3d2eb754b7d7f0d997f58b0b6cc4e3fe1a7e0788dea610bf42c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=10108255&rfr_iscdi=true