Loading…

Test results of HTS dipole

Test of HTS dipole with coil wound by Bi-2223 tape was carried out. Volt-current characteristics of the dipole at various temperatures as well as results of magnetic field measurements are presented. A process of transition to normal state for the HTS coil was calculated.

Saved in:
Bibliographic Details
Published in:IEEE transactions on applied superconductivity 2002-03, Vol.12 (1), p.125-128
Main Authors: Ageev, A.I., Akirnov, I.I., Andriishchin, A.M., Bogdanov, I.V., Kozub, S.S., Myznikov, K.P., Rakov, D.N., Rekudanov, A.V., Shcherbakov, P.A., Slabodchikov, P.I., Seletsky, A.A., Shikov, A.K., Sytnik, V.V., Tikhov, A.V., Tkachenko, L.M., Zubko, V.V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Test of HTS dipole with coil wound by Bi-2223 tape was carried out. Volt-current characteristics of the dipole at various temperatures as well as results of magnetic field measurements are presented. A process of transition to normal state for the HTS coil was calculated.
ISSN:1051-8223
1558-2515
DOI:10.1109/TASC.2002.1018366