Performance evolution of Nb/sub 3/Sn cable-in-conduit conductors under cyclic load [for Tokamaks]
Two subsize, Nb/sub 3/Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I/sub c/ and n-factor is observed upon cyclic load, with a d...
Saved in:
Published in: | IEEE transactions on applied superconductivity 2002-03, Vol.12 (1), p.516-519 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Two subsize, Nb/sub 3/Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I/sub c/ and n-factor is observed upon cyclic load, with a drop of the critical current, I/sub c/, larger than 30%. The results are critically discussed and compared to similar findings from the literature. The impact of the cyclic load on the Nb/sub 3/Sn CICC performance must be carefully evaluated in the magnet design. |
---|---|
ISSN: | 1051-8223 1558-2515 |