Performance evolution of Nb/sub 3/Sn cable-in-conduit conductors under cyclic load [for Tokamaks]

Two subsize, Nb/sub 3/Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I/sub c/ and n-factor is observed upon cyclic load, with a d...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on applied superconductivity 2002-03, Vol.12 (1), p.516-519
Main Authors: Bruzzone, P., Fuchs, A.M., Stepanov, B., Vecsey, G.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Two subsize, Nb/sub 3/Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I/sub c/ and n-factor is observed upon cyclic load, with a drop of the critical current, I/sub c/, larger than 30%. The results are critically discussed and compared to similar findings from the literature. The impact of the cyclic load on the Nb/sub 3/Sn CICC performance must be carefully evaluated in the magnet design.
ISSN:1051-8223
1558-2515
DOI:10.1109/TASC.2002.1018456