Experimental Verification of Characteristic Mode Analysis (CMA) using Reverberation Chamber
In this work, a novel experimental validation of characteristic mode analysis (CMA) is proposed using reverberation chamber measurements. Using the modal weighting coefficient formulation based on the magnetic moment and modal H field obtained from solvers, the total radiated power (TRP) is calculat...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 4 |
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Manoharan, Haran Wang, Xu Wu, Matthew Rajagopalan, Jagan Mohan, Akshay Hwang, Chulsoon |
description | In this work, a novel experimental validation of characteristic mode analysis (CMA) is proposed using reverberation chamber measurements. Using the modal weighting coefficient formulation based on the magnetic moment and modal H field obtained from solvers, the total radiated power (TRP) is calculated. This TRP is compared with the TRP obtained from the reverberation chamber measurements. A good correlation between the simulation and measurement was achieved for a simple rectangular plate of size 15 cm × 8 cm with an error of less than 4 dB. |
doi_str_mv | 10.1109/APEMC57782.2023.10217353 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_10217353</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10217353</ieee_id><sourcerecordid>10217353</sourcerecordid><originalsourceid>FETCH-LOGICAL-i204t-fe7c5edb512d192a8c5e4b1b69c52df9b9d39cbf186743df3ad5345dc3fa5a4b3</originalsourceid><addsrcrecordid>eNo1UM1LwzAcjYLgmPsPPOSoh84kv6RJjqVMJ6wool48jHxqpGtHU8X99xamp_cB78F7CGFKlpQSfVM9rppaSKnYkhEGS0oYlSDgBC201AoEAVDA1SmasZKTQvJSn6NFzp-EEEYIpaWaobfVzz4MaRe60bT4daIxOTOmvsN9xPWHGYwbJzePyeGm9wFXnWkPOWV8VTfVNf7KqXvHT-E7DDYMx-QU203iAp1F0-aw-MM5erldPdfrYvNwd19XmyIxwsciBulE8FZQ5qlmRk2KW2pL7QTzUVvtQTsbqSolBx_BeAFceAfRCMMtzNHlsTeFELb7aY0ZDtv_P-AXcCVWdA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Experimental Verification of Characteristic Mode Analysis (CMA) using Reverberation Chamber</title><source>IEEE Xplore All Conference Series</source><creator>Manoharan, Haran ; Wang, Xu ; Wu, Matthew ; Rajagopalan, Jagan ; Mohan, Akshay ; Hwang, Chulsoon</creator><creatorcontrib>Manoharan, Haran ; Wang, Xu ; Wu, Matthew ; Rajagopalan, Jagan ; Mohan, Akshay ; Hwang, Chulsoon</creatorcontrib><description>In this work, a novel experimental validation of characteristic mode analysis (CMA) is proposed using reverberation chamber measurements. Using the modal weighting coefficient formulation based on the magnetic moment and modal H field obtained from solvers, the total radiated power (TRP) is calculated. This TRP is compared with the TRP obtained from the reverberation chamber measurements. A good correlation between the simulation and measurement was achieved for a simple rectangular plate of size 15 cm × 8 cm with an error of less than 4 dB.</description><identifier>EISSN: 2640-7469</identifier><identifier>EISBN: 9798350338348</identifier><identifier>DOI: 10.1109/APEMC57782.2023.10217353</identifier><language>eng</language><publisher>IEEE</publisher><subject>characteristic mode analysis ; CMA ; Correlation ; Frequency measurement ; Magnetic field measurement ; Magnetic moments ; Measurement uncertainty ; modal weighting coefficients ; reverberation chamber ; Reverberation chambers ; Size measurement ; total radiated power</subject><ispartof>2023 Joint Asia-Pacific International Symposium on Electromagnetic Compatibility and International Conference on ElectroMagnetic Interference & Compatibility (APEMC/INCEMIC), 2023, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10217353$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10217353$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Manoharan, Haran</creatorcontrib><creatorcontrib>Wang, Xu</creatorcontrib><creatorcontrib>Wu, Matthew</creatorcontrib><creatorcontrib>Rajagopalan, Jagan</creatorcontrib><creatorcontrib>Mohan, Akshay</creatorcontrib><creatorcontrib>Hwang, Chulsoon</creatorcontrib><title>Experimental Verification of Characteristic Mode Analysis (CMA) using Reverberation Chamber</title><title>2023 Joint Asia-Pacific International Symposium on Electromagnetic Compatibility and International Conference on ElectroMagnetic Interference & Compatibility (APEMC/INCEMIC)</title><addtitle>APEMC</addtitle><description>In this work, a novel experimental validation of characteristic mode analysis (CMA) is proposed using reverberation chamber measurements. Using the modal weighting coefficient formulation based on the magnetic moment and modal H field obtained from solvers, the total radiated power (TRP) is calculated. This TRP is compared with the TRP obtained from the reverberation chamber measurements. A good correlation between the simulation and measurement was achieved for a simple rectangular plate of size 15 cm × 8 cm with an error of less than 4 dB.</description><subject>characteristic mode analysis</subject><subject>CMA</subject><subject>Correlation</subject><subject>Frequency measurement</subject><subject>Magnetic field measurement</subject><subject>Magnetic moments</subject><subject>Measurement uncertainty</subject><subject>modal weighting coefficients</subject><subject>reverberation chamber</subject><subject>Reverberation chambers</subject><subject>Size measurement</subject><subject>total radiated power</subject><issn>2640-7469</issn><isbn>9798350338348</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2023</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo1UM1LwzAcjYLgmPsPPOSoh84kv6RJjqVMJ6wool48jHxqpGtHU8X99xamp_cB78F7CGFKlpQSfVM9rppaSKnYkhEGS0oYlSDgBC201AoEAVDA1SmasZKTQvJSn6NFzp-EEEYIpaWaobfVzz4MaRe60bT4daIxOTOmvsN9xPWHGYwbJzePyeGm9wFXnWkPOWV8VTfVNf7KqXvHT-E7DDYMx-QU203iAp1F0-aw-MM5erldPdfrYvNwd19XmyIxwsciBulE8FZQ5qlmRk2KW2pL7QTzUVvtQTsbqSolBx_BeAFceAfRCMMtzNHlsTeFELb7aY0ZDtv_P-AXcCVWdA</recordid><startdate>20230523</startdate><enddate>20230523</enddate><creator>Manoharan, Haran</creator><creator>Wang, Xu</creator><creator>Wu, Matthew</creator><creator>Rajagopalan, Jagan</creator><creator>Mohan, Akshay</creator><creator>Hwang, Chulsoon</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>20230523</creationdate><title>Experimental Verification of Characteristic Mode Analysis (CMA) using Reverberation Chamber</title><author>Manoharan, Haran ; Wang, Xu ; Wu, Matthew ; Rajagopalan, Jagan ; Mohan, Akshay ; Hwang, Chulsoon</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i204t-fe7c5edb512d192a8c5e4b1b69c52df9b9d39cbf186743df3ad5345dc3fa5a4b3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2023</creationdate><topic>characteristic mode analysis</topic><topic>CMA</topic><topic>Correlation</topic><topic>Frequency measurement</topic><topic>Magnetic field measurement</topic><topic>Magnetic moments</topic><topic>Measurement uncertainty</topic><topic>modal weighting coefficients</topic><topic>reverberation chamber</topic><topic>Reverberation chambers</topic><topic>Size measurement</topic><topic>total radiated power</topic><toplevel>online_resources</toplevel><creatorcontrib>Manoharan, Haran</creatorcontrib><creatorcontrib>Wang, Xu</creatorcontrib><creatorcontrib>Wu, Matthew</creatorcontrib><creatorcontrib>Rajagopalan, Jagan</creatorcontrib><creatorcontrib>Mohan, Akshay</creatorcontrib><creatorcontrib>Hwang, Chulsoon</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore (Online service)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Manoharan, Haran</au><au>Wang, Xu</au><au>Wu, Matthew</au><au>Rajagopalan, Jagan</au><au>Mohan, Akshay</au><au>Hwang, Chulsoon</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Experimental Verification of Characteristic Mode Analysis (CMA) using Reverberation Chamber</atitle><btitle>2023 Joint Asia-Pacific International Symposium on Electromagnetic Compatibility and International Conference on ElectroMagnetic Interference & Compatibility (APEMC/INCEMIC)</btitle><stitle>APEMC</stitle><date>2023-05-23</date><risdate>2023</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><eissn>2640-7469</eissn><eisbn>9798350338348</eisbn><abstract>In this work, a novel experimental validation of characteristic mode analysis (CMA) is proposed using reverberation chamber measurements. Using the modal weighting coefficient formulation based on the magnetic moment and modal H field obtained from solvers, the total radiated power (TRP) is calculated. This TRP is compared with the TRP obtained from the reverberation chamber measurements. A good correlation between the simulation and measurement was achieved for a simple rectangular plate of size 15 cm × 8 cm with an error of less than 4 dB.</abstract><pub>IEEE</pub><doi>10.1109/APEMC57782.2023.10217353</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | EISSN: 2640-7469 |
ispartof | 2023 Joint Asia-Pacific International Symposium on Electromagnetic Compatibility and International Conference on ElectroMagnetic Interference & Compatibility (APEMC/INCEMIC), 2023, p.1-4 |
issn | 2640-7469 |
language | eng |
recordid | cdi_ieee_primary_10217353 |
source | IEEE Xplore All Conference Series |
subjects | characteristic mode analysis CMA Correlation Frequency measurement Magnetic field measurement Magnetic moments Measurement uncertainty modal weighting coefficients reverberation chamber Reverberation chambers Size measurement total radiated power |
title | Experimental Verification of Characteristic Mode Analysis (CMA) using Reverberation Chamber |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T20%3A48%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Experimental%20Verification%20of%20Characteristic%20Mode%20Analysis%20(CMA)%20using%20Reverberation%20Chamber&rft.btitle=2023%20Joint%20Asia-Pacific%20International%20Symposium%20on%20Electromagnetic%20Compatibility%20and%20International%20Conference%20on%20ElectroMagnetic%20Interference%20&%20Compatibility%20(APEMC/INCEMIC)&rft.au=Manoharan,%20Haran&rft.date=2023-05-23&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.eissn=2640-7469&rft_id=info:doi/10.1109/APEMC57782.2023.10217353&rft.eisbn=9798350338348&rft_dat=%3Cieee_CHZPO%3E10217353%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i204t-fe7c5edb512d192a8c5e4b1b69c52df9b9d39cbf186743df3ad5345dc3fa5a4b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=10217353&rfr_iscdi=true |