Loading…

Estimates of the Distortion Contribution From the Reference Sensor to the Calibration Results of the Built-in Angle Sensors

The paper proposes an alternative approach that provides high-precision calibration of built-in angle encoders included in angle measuring setups using available control means. The approach is based on the complex use of modern variants of realization of cross- and autocalibration methods. It is sho...

Full description

Saved in:
Bibliographic Details
Main Authors: Kiryanov, Alexey V., Kiryanov, Valeriy P.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1315
container_issue
container_start_page 1310
container_title
container_volume
creator Kiryanov, Alexey V.
Kiryanov, Valeriy P.
description The paper proposes an alternative approach that provides high-precision calibration of built-in angle encoders included in angle measuring setups using available control means. The approach is based on the complex use of modern variants of realization of cross- and autocalibration methods. It is shown that algorithmically the procedure of cross-calibration of one scale with the help of another is identical to the procedure of autocalibration in multi-headed angle encoders whose readout heads are localized according to the prescriptions of basic methods, including the Watanabe multi-combination method. It is shown that the uncertainty of calibration of angle sensors of the built-in type can be reduced from the initial level of ±1.3ʺ, which characterizes the instrumental error of manufacturing the scale of the controlling sensor, to the required level, estimated as ±0.02ʺ, in just 15 comparisons of all scale bars of the controlled sensor with all scale bars of the four-headed controlling sensor, taken as a standard of comparison.
doi_str_mv 10.1109/APEIE59731.2023.10347829
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_10347829</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10347829</ieee_id><sourcerecordid>10347829</sourcerecordid><originalsourceid>FETCH-LOGICAL-i119t-f3923ea4c06706d6362014f6cfc82771516d2c4767b096f51f211fddb1068b403</originalsourceid><addsrcrecordid>eNo9UM1OwzAYC0hIjLE34JAX6Pi-pM3PsZQOJk0CDThP_UkgqGtQkh0QLw8qjJNly7ZkE0IRloigr8vHel0XWnJcMmB8icBzqZg-IQstteIFcA5KFadkxnLJM1VIfk4uYnwH4AoZzMhXHZPbN8lE6i1Nb4beuph8SM6PtPJjCq49TGQV_H4ybI01wYydoU9mjD7Q5Ce9agbXhmYyb008DOm_8-bghpS5kZbj63DMxUtyZpshmsUfzsnLqn6u7rPNw926KjeZQ9Qps1wzbpq8AyFB9IILBphb0dlOMSmxQNGzLpdCtqCFLdAyRNv3LYJQbQ58Tq5-e50xZvcRfvaGz93xLP4NX3Zfxw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Estimates of the Distortion Contribution From the Reference Sensor to the Calibration Results of the Built-in Angle Sensors</title><source>IEEE Xplore All Conference Series</source><creator>Kiryanov, Alexey V. ; Kiryanov, Valeriy P.</creator><creatorcontrib>Kiryanov, Alexey V. ; Kiryanov, Valeriy P.</creatorcontrib><description>The paper proposes an alternative approach that provides high-precision calibration of built-in angle encoders included in angle measuring setups using available control means. The approach is based on the complex use of modern variants of realization of cross- and autocalibration methods. It is shown that algorithmically the procedure of cross-calibration of one scale with the help of another is identical to the procedure of autocalibration in multi-headed angle encoders whose readout heads are localized according to the prescriptions of basic methods, including the Watanabe multi-combination method. It is shown that the uncertainty of calibration of angle sensors of the built-in type can be reduced from the initial level of ±1.3ʺ, which characterizes the instrumental error of manufacturing the scale of the controlling sensor, to the required level, estimated as ±0.02ʺ, in just 15 comparisons of all scale bars of the controlled sensor with all scale bars of the four-headed controlling sensor, taken as a standard of comparison.</description><identifier>EISSN: 2473-8573</identifier><identifier>EISBN: 9798350330885</identifier><identifier>DOI: 10.1109/APEIE59731.2023.10347829</identifier><language>eng</language><publisher>IEEE</publisher><subject>angle comparators ; angle encode ; angle measuring machine ; angle sensor ; autocalibration ; Calibration ; cross-calibration ; Distortion ; Instruments ; laser pattern generator ; Magnetic heads ; Manufacturing ; Sensor phenomena and characterization ; Uncertainty ; Watanabe multicombination method</subject><ispartof>2023 IEEE XVI International Scientific and Technical Conference Actual Problems of Electronic Instrument Engineering (APEIE), 2023, p.1310-1315</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10347829$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,27904,54533,54910</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10347829$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kiryanov, Alexey V.</creatorcontrib><creatorcontrib>Kiryanov, Valeriy P.</creatorcontrib><title>Estimates of the Distortion Contribution From the Reference Sensor to the Calibration Results of the Built-in Angle Sensors</title><title>2023 IEEE XVI International Scientific and Technical Conference Actual Problems of Electronic Instrument Engineering (APEIE)</title><addtitle>APEIE</addtitle><description>The paper proposes an alternative approach that provides high-precision calibration of built-in angle encoders included in angle measuring setups using available control means. The approach is based on the complex use of modern variants of realization of cross- and autocalibration methods. It is shown that algorithmically the procedure of cross-calibration of one scale with the help of another is identical to the procedure of autocalibration in multi-headed angle encoders whose readout heads are localized according to the prescriptions of basic methods, including the Watanabe multi-combination method. It is shown that the uncertainty of calibration of angle sensors of the built-in type can be reduced from the initial level of ±1.3ʺ, which characterizes the instrumental error of manufacturing the scale of the controlling sensor, to the required level, estimated as ±0.02ʺ, in just 15 comparisons of all scale bars of the controlled sensor with all scale bars of the four-headed controlling sensor, taken as a standard of comparison.</description><subject>angle comparators</subject><subject>angle encode</subject><subject>angle measuring machine</subject><subject>angle sensor</subject><subject>autocalibration</subject><subject>Calibration</subject><subject>cross-calibration</subject><subject>Distortion</subject><subject>Instruments</subject><subject>laser pattern generator</subject><subject>Magnetic heads</subject><subject>Manufacturing</subject><subject>Sensor phenomena and characterization</subject><subject>Uncertainty</subject><subject>Watanabe multicombination method</subject><issn>2473-8573</issn><isbn>9798350330885</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2023</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo9UM1OwzAYC0hIjLE34JAX6Pi-pM3PsZQOJk0CDThP_UkgqGtQkh0QLw8qjJNly7ZkE0IRloigr8vHel0XWnJcMmB8icBzqZg-IQstteIFcA5KFadkxnLJM1VIfk4uYnwH4AoZzMhXHZPbN8lE6i1Nb4beuph8SM6PtPJjCq49TGQV_H4ybI01wYydoU9mjD7Q5Ce9agbXhmYyb008DOm_8-bghpS5kZbj63DMxUtyZpshmsUfzsnLqn6u7rPNw926KjeZQ9Qps1wzbpq8AyFB9IILBphb0dlOMSmxQNGzLpdCtqCFLdAyRNv3LYJQbQ58Tq5-e50xZvcRfvaGz93xLP4NX3Zfxw</recordid><startdate>20231110</startdate><enddate>20231110</enddate><creator>Kiryanov, Alexey V.</creator><creator>Kiryanov, Valeriy P.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>20231110</creationdate><title>Estimates of the Distortion Contribution From the Reference Sensor to the Calibration Results of the Built-in Angle Sensors</title><author>Kiryanov, Alexey V. ; Kiryanov, Valeriy P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i119t-f3923ea4c06706d6362014f6cfc82771516d2c4767b096f51f211fddb1068b403</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2023</creationdate><topic>angle comparators</topic><topic>angle encode</topic><topic>angle measuring machine</topic><topic>angle sensor</topic><topic>autocalibration</topic><topic>Calibration</topic><topic>cross-calibration</topic><topic>Distortion</topic><topic>Instruments</topic><topic>laser pattern generator</topic><topic>Magnetic heads</topic><topic>Manufacturing</topic><topic>Sensor phenomena and characterization</topic><topic>Uncertainty</topic><topic>Watanabe multicombination method</topic><toplevel>online_resources</toplevel><creatorcontrib>Kiryanov, Alexey V.</creatorcontrib><creatorcontrib>Kiryanov, Valeriy P.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kiryanov, Alexey V.</au><au>Kiryanov, Valeriy P.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Estimates of the Distortion Contribution From the Reference Sensor to the Calibration Results of the Built-in Angle Sensors</atitle><btitle>2023 IEEE XVI International Scientific and Technical Conference Actual Problems of Electronic Instrument Engineering (APEIE)</btitle><stitle>APEIE</stitle><date>2023-11-10</date><risdate>2023</risdate><spage>1310</spage><epage>1315</epage><pages>1310-1315</pages><eissn>2473-8573</eissn><eisbn>9798350330885</eisbn><abstract>The paper proposes an alternative approach that provides high-precision calibration of built-in angle encoders included in angle measuring setups using available control means. The approach is based on the complex use of modern variants of realization of cross- and autocalibration methods. It is shown that algorithmically the procedure of cross-calibration of one scale with the help of another is identical to the procedure of autocalibration in multi-headed angle encoders whose readout heads are localized according to the prescriptions of basic methods, including the Watanabe multi-combination method. It is shown that the uncertainty of calibration of angle sensors of the built-in type can be reduced from the initial level of ±1.3ʺ, which characterizes the instrumental error of manufacturing the scale of the controlling sensor, to the required level, estimated as ±0.02ʺ, in just 15 comparisons of all scale bars of the controlled sensor with all scale bars of the four-headed controlling sensor, taken as a standard of comparison.</abstract><pub>IEEE</pub><doi>10.1109/APEIE59731.2023.10347829</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 2473-8573
ispartof 2023 IEEE XVI International Scientific and Technical Conference Actual Problems of Electronic Instrument Engineering (APEIE), 2023, p.1310-1315
issn 2473-8573
language eng
recordid cdi_ieee_primary_10347829
source IEEE Xplore All Conference Series
subjects angle comparators
angle encode
angle measuring machine
angle sensor
autocalibration
Calibration
cross-calibration
Distortion
Instruments
laser pattern generator
Magnetic heads
Manufacturing
Sensor phenomena and characterization
Uncertainty
Watanabe multicombination method
title Estimates of the Distortion Contribution From the Reference Sensor to the Calibration Results of the Built-in Angle Sensors
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T23%3A58%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Estimates%20of%20the%20Distortion%20Contribution%20From%20the%20Reference%20Sensor%20to%20the%20Calibration%20Results%20of%20the%20Built-in%20Angle%20Sensors&rft.btitle=2023%20IEEE%20XVI%20International%20Scientific%20and%20Technical%20Conference%20Actual%20Problems%20of%20Electronic%20Instrument%20Engineering%20(APEIE)&rft.au=Kiryanov,%20Alexey%20V.&rft.date=2023-11-10&rft.spage=1310&rft.epage=1315&rft.pages=1310-1315&rft.eissn=2473-8573&rft_id=info:doi/10.1109/APEIE59731.2023.10347829&rft.eisbn=9798350330885&rft_dat=%3Cieee_CHZPO%3E10347829%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i119t-f3923ea4c06706d6362014f6cfc82771516d2c4767b096f51f211fddb1068b403%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=10347829&rfr_iscdi=true