Loading…
Non invasive ultrasonic detector for monitoring gastric motility in rats, using a emitter based on a crystal oscillator
An ultrasonic system for in-vivo monitoring of the gastric motility in rat is presented. This non-invasive technique allows to obtain both the qualitative gastric motility and electrical signals simultaneously without loading excessively the stomach of the subject under study. The system includes a...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | An ultrasonic system for in-vivo monitoring of the gastric motility in rat is presented. This non-invasive technique allows to obtain both the qualitative gastric motility and electrical signals simultaneously without loading excessively the stomach of the subject under study. The system includes a crystal-based oscillator to stabilize the output signal. Comparative measurements were made using a strain gage device and results showed a good qualitative relationship. |
---|---|
ISSN: | 1094-687X 1558-4615 |
DOI: | 10.1109/IEMBS.2002.1053027 |