Stability measurements between Hg/sup +/ lite 12-pole clocks

We describe frequency stability measurements of two Hg-ion clocks based upon linear 12-pole shuttle ion traps. The inter-comparison was carried out over several multi-day intervals with the short-term stability of each clock better than 2/spl times/10/sup -13/ at 1 second. Longer-term stability as g...

Full description

Saved in:
Bibliographic Details
Main Authors: Prestage, J.D., Chung, S., Burt, E., Maleki, L., Tjoelker, R.L.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We describe frequency stability measurements of two Hg-ion clocks based upon linear 12-pole shuttle ion traps. The inter-comparison was carried out over several multi-day intervals with the short-term stability of each clock better than 2/spl times/10/sup -13/ at 1 second. Longer-term stability as good as 3/spl times/10/sup -16/ was demonstrated for these clocks.
DOI:10.1109/FREQ.2002.1075926