Loading…
A 500 Hz predictive visual servoing scheme to mechanically filter complex repetitive organ motions in robotized surgery
Periodic deformations of organs and soft tissues are complex, repetitive disturbances for surgeons manipulating robotic interfaces in computer-assisted surgery. They are due to respiratory movements or heart beats, and they have to be manually compensated for by the surgeon whenever accurate gesture...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 3366 vol.3 |
container_issue | |
container_start_page | 3361 |
container_title | |
container_volume | 4 |
creator | Ginhoux, R. Gangloff, J.A. de Mathelin, M.F. Soler, L. Leroy, J. Marescaux, J. |
description | Periodic deformations of organs and soft tissues are complex, repetitive disturbances for surgeons manipulating robotic interfaces in computer-assisted surgery. They are due to respiratory movements or heart beats, and they have to be manually compensated for by the surgeon whenever accurate gestures are needed, as it is the case in cardiac or robotized laparoscopic surgery. This work presents a repetitive model predictive control scheme for the cancellation of fast periodic motions by a robot arm, which is controlled by visual servoing at 500 Hz by means of a high-speed camera. The problem we address is to keep a constant distance in the camera images from a surgical tool's tip to the organ surface. Contributions of the control input to reference tracking and to the fast-disturbance rejection are split and computed separately to ensure that the surgeon's interaction on the robot bas no influence on the cancellation performance. The system is tested in a laboratory experiment with an experimental surgical arm and in in vivo conditions on a living pig with a standard surgical robot. Results show the effectiveness and the potential of the proposed control scheme. |
doi_str_mv | 10.1109/IROS.2003.1249675 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1249675</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1249675</ieee_id><sourcerecordid>1249675</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-1073e2fc25ebf76ad3af5b06fd5224dabe79e32b45a58096e8ecc156bd253b963</originalsourceid><addsrcrecordid>eNotkM1KAzEURgMiqLUPIG7uC7TeJJPMzLIUtYVCwZ91STJ32sjMZEim1fbpLdpvczibs_gYe-A45RzLp-Xb-n0qEOWUi6zUubpid5gXKPNCI79h45S-8LxMZRrFLfuegUKExQn6SJV3gz8QHHzamwYSxUPw3RaS21FLMARoye1M551pmiPUvhkoggtt39APROpp8H-BELemgzYMPnQJfAcx2LOcqIK0j1uKx3t2XZsm0fjCEft8ef6YLyar9etyPltNPEc1TDjmkkTthCJb59pU0tTKoq4rJURWGUt5SVLYTBlVYKmpIOe40rYSStpSyxF7_O96Itr00bcmHjeXb-QvjNZc_g</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A 500 Hz predictive visual servoing scheme to mechanically filter complex repetitive organ motions in robotized surgery</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ginhoux, R. ; Gangloff, J.A. ; de Mathelin, M.F. ; Soler, L. ; Leroy, J. ; Marescaux, J.</creator><creatorcontrib>Ginhoux, R. ; Gangloff, J.A. ; de Mathelin, M.F. ; Soler, L. ; Leroy, J. ; Marescaux, J.</creatorcontrib><description>Periodic deformations of organs and soft tissues are complex, repetitive disturbances for surgeons manipulating robotic interfaces in computer-assisted surgery. They are due to respiratory movements or heart beats, and they have to be manually compensated for by the surgeon whenever accurate gestures are needed, as it is the case in cardiac or robotized laparoscopic surgery. This work presents a repetitive model predictive control scheme for the cancellation of fast periodic motions by a robot arm, which is controlled by visual servoing at 500 Hz by means of a high-speed camera. The problem we address is to keep a constant distance in the camera images from a surgical tool's tip to the organ surface. Contributions of the control input to reference tracking and to the fast-disturbance rejection are split and computed separately to ensure that the surgeon's interaction on the robot bas no influence on the cancellation performance. The system is tested in a laboratory experiment with an experimental surgical arm and in in vivo conditions on a living pig with a standard surgical robot. Results show the effectiveness and the potential of the proposed control scheme.</description><identifier>ISBN: 0780378601</identifier><identifier>ISBN: 9780780378605</identifier><identifier>DOI: 10.1109/IROS.2003.1249675</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biological tissues ; Cameras ; Computer interfaces ; Filters ; Heart beat ; Minimally invasive surgery ; Predictive control ; Predictive models ; Robot vision systems ; Visual servoing</subject><ispartof>Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453), 2003, Vol.4, p.3361-3366 vol.3</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1249675$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,4036,4037,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1249675$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ginhoux, R.</creatorcontrib><creatorcontrib>Gangloff, J.A.</creatorcontrib><creatorcontrib>de Mathelin, M.F.</creatorcontrib><creatorcontrib>Soler, L.</creatorcontrib><creatorcontrib>Leroy, J.</creatorcontrib><creatorcontrib>Marescaux, J.</creatorcontrib><title>A 500 Hz predictive visual servoing scheme to mechanically filter complex repetitive organ motions in robotized surgery</title><title>Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453)</title><addtitle>IROS</addtitle><description>Periodic deformations of organs and soft tissues are complex, repetitive disturbances for surgeons manipulating robotic interfaces in computer-assisted surgery. They are due to respiratory movements or heart beats, and they have to be manually compensated for by the surgeon whenever accurate gestures are needed, as it is the case in cardiac or robotized laparoscopic surgery. This work presents a repetitive model predictive control scheme for the cancellation of fast periodic motions by a robot arm, which is controlled by visual servoing at 500 Hz by means of a high-speed camera. The problem we address is to keep a constant distance in the camera images from a surgical tool's tip to the organ surface. Contributions of the control input to reference tracking and to the fast-disturbance rejection are split and computed separately to ensure that the surgeon's interaction on the robot bas no influence on the cancellation performance. The system is tested in a laboratory experiment with an experimental surgical arm and in in vivo conditions on a living pig with a standard surgical robot. Results show the effectiveness and the potential of the proposed control scheme.</description><subject>Biological tissues</subject><subject>Cameras</subject><subject>Computer interfaces</subject><subject>Filters</subject><subject>Heart beat</subject><subject>Minimally invasive surgery</subject><subject>Predictive control</subject><subject>Predictive models</subject><subject>Robot vision systems</subject><subject>Visual servoing</subject><isbn>0780378601</isbn><isbn>9780780378605</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2003</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkM1KAzEURgMiqLUPIG7uC7TeJJPMzLIUtYVCwZ91STJ32sjMZEim1fbpLdpvczibs_gYe-A45RzLp-Xb-n0qEOWUi6zUubpid5gXKPNCI79h45S-8LxMZRrFLfuegUKExQn6SJV3gz8QHHzamwYSxUPw3RaS21FLMARoye1M551pmiPUvhkoggtt39APROpp8H-BELemgzYMPnQJfAcx2LOcqIK0j1uKx3t2XZsm0fjCEft8ef6YLyar9etyPltNPEc1TDjmkkTthCJb59pU0tTKoq4rJURWGUt5SVLYTBlVYKmpIOe40rYSStpSyxF7_O96Itr00bcmHjeXb-QvjNZc_g</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>Ginhoux, R.</creator><creator>Gangloff, J.A.</creator><creator>de Mathelin, M.F.</creator><creator>Soler, L.</creator><creator>Leroy, J.</creator><creator>Marescaux, J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2003</creationdate><title>A 500 Hz predictive visual servoing scheme to mechanically filter complex repetitive organ motions in robotized surgery</title><author>Ginhoux, R. ; Gangloff, J.A. ; de Mathelin, M.F. ; Soler, L. ; Leroy, J. ; Marescaux, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-1073e2fc25ebf76ad3af5b06fd5224dabe79e32b45a58096e8ecc156bd253b963</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Biological tissues</topic><topic>Cameras</topic><topic>Computer interfaces</topic><topic>Filters</topic><topic>Heart beat</topic><topic>Minimally invasive surgery</topic><topic>Predictive control</topic><topic>Predictive models</topic><topic>Robot vision systems</topic><topic>Visual servoing</topic><toplevel>online_resources</toplevel><creatorcontrib>Ginhoux, R.</creatorcontrib><creatorcontrib>Gangloff, J.A.</creatorcontrib><creatorcontrib>de Mathelin, M.F.</creatorcontrib><creatorcontrib>Soler, L.</creatorcontrib><creatorcontrib>Leroy, J.</creatorcontrib><creatorcontrib>Marescaux, J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ginhoux, R.</au><au>Gangloff, J.A.</au><au>de Mathelin, M.F.</au><au>Soler, L.</au><au>Leroy, J.</au><au>Marescaux, J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A 500 Hz predictive visual servoing scheme to mechanically filter complex repetitive organ motions in robotized surgery</atitle><btitle>Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453)</btitle><stitle>IROS</stitle><date>2003</date><risdate>2003</risdate><volume>4</volume><spage>3361</spage><epage>3366 vol.3</epage><pages>3361-3366 vol.3</pages><isbn>0780378601</isbn><isbn>9780780378605</isbn><abstract>Periodic deformations of organs and soft tissues are complex, repetitive disturbances for surgeons manipulating robotic interfaces in computer-assisted surgery. They are due to respiratory movements or heart beats, and they have to be manually compensated for by the surgeon whenever accurate gestures are needed, as it is the case in cardiac or robotized laparoscopic surgery. This work presents a repetitive model predictive control scheme for the cancellation of fast periodic motions by a robot arm, which is controlled by visual servoing at 500 Hz by means of a high-speed camera. The problem we address is to keep a constant distance in the camera images from a surgical tool's tip to the organ surface. Contributions of the control input to reference tracking and to the fast-disturbance rejection are split and computed separately to ensure that the surgeon's interaction on the robot bas no influence on the cancellation performance. The system is tested in a laboratory experiment with an experimental surgical arm and in in vivo conditions on a living pig with a standard surgical robot. Results show the effectiveness and the potential of the proposed control scheme.</abstract><pub>IEEE</pub><doi>10.1109/IROS.2003.1249675</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 0780378601 |
ispartof | Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453), 2003, Vol.4, p.3361-3366 vol.3 |
issn | |
language | eng |
recordid | cdi_ieee_primary_1249675 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Biological tissues Cameras Computer interfaces Filters Heart beat Minimally invasive surgery Predictive control Predictive models Robot vision systems Visual servoing |
title | A 500 Hz predictive visual servoing scheme to mechanically filter complex repetitive organ motions in robotized surgery |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T02%3A01%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20500%20Hz%20predictive%20visual%20servoing%20scheme%20to%20mechanically%20filter%20complex%20repetitive%20organ%20motions%20in%20robotized%20surgery&rft.btitle=Proceedings%202003%20IEEE/RSJ%20International%20Conference%20on%20Intelligent%20Robots%20and%20Systems%20(IROS%202003)%20(Cat.%20No.03CH37453)&rft.au=Ginhoux,%20R.&rft.date=2003&rft.volume=4&rft.spage=3361&rft.epage=3366%20vol.3&rft.pages=3361-3366%20vol.3&rft.isbn=0780378601&rft.isbn_list=9780780378605&rft_id=info:doi/10.1109/IROS.2003.1249675&rft_dat=%3Cieee_6IE%3E1249675%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i105t-1073e2fc25ebf76ad3af5b06fd5224dabe79e32b45a58096e8ecc156bd253b963%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1249675&rfr_iscdi=true |