Primary high-current testing of relays with low ratio current transformers
This paper serves as one of few references describing primary high-current testing of protective relays using low ratio current transformers. Accurate measurement of high-current magnitudes requires high ratio current transformers. However, it is the practice to apply low ratio CTs based on small mo...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 189 |
container_issue | |
container_start_page | 182 |
container_title | |
container_volume | |
creator | Zocholl, S.E. Mooney, J. |
description | This paper serves as one of few references describing primary high-current testing of protective relays using low ratio current transformers. Accurate measurement of high-current magnitudes requires high ratio current transformers. However, it is the practice to apply low ratio CTs based on small motor loads. The protection engineer then relies on the motor relay to trip for the enormous current of a phase-to-phase fault in the motor cable. The assumption is that fault current exceeding 300 times the CT rating can produce a secondary current large enough for a fast instantaneous trip. This leap of faith is based on the lack of knowledge of the highly distorted secondary waveform and how it is processed in the relay. The tests show the limitations of Fourier and cosine filters used in microprocessor relays that extract the fundamental phasors and eliminate harmonics. The tests validate the operation of a cosine-peak adaptive filter designed to cope with the highly distorted saturated waveforms produced by the low ratio CTs subjected to high current. This paper also reports on the results of primary high-current tests of overcurrent, motor, and distance relays using low ratio CTs. Lastly, this paper compares the internal unfiltered event records with MATLAB/spl reg/ simulations of the same cases. |
doi_str_mv | 10.1109/CPRE.2004.238491 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1287093</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1287093</ieee_id><sourcerecordid>1287093</sourcerecordid><originalsourceid>FETCH-LOGICAL-i173t-94544cae172765c791ebe4f633b2111bd512de47896e9cc7196b84638f0962f53</originalsourceid><addsrcrecordid>eNo9jk1LAzEURQMiqLV7wU3-wIx5-c5ShqqVgkV0XTLTl05kOiNJpPTfW6h4N_csLodLyB2wGoC5h2b9vqg5Y7LmwkoHF-SGGctOLLi-IvOcv9gpUoGy6pq8rlPc-3Skfdz1VfeTEo6FFswljjs6BZpw8MdMD7H0dJgONPkSJ_o_TH7MYUp7TPmWXAY_ZJz_9Yx8Pi0-mpdq9fa8bB5XVQQjSuWkkrLzCIYbrTrjAFuUQQvRcgBotwr4FqWxTqPrOgNOt1ZqYQNzmgclZuT-7I2IuPk-_98At4Y5IX4BX11LGQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Primary high-current testing of relays with low ratio current transformers</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Zocholl, S.E. ; Mooney, J.</creator><creatorcontrib>Zocholl, S.E. ; Mooney, J.</creatorcontrib><description>This paper serves as one of few references describing primary high-current testing of protective relays using low ratio current transformers. Accurate measurement of high-current magnitudes requires high ratio current transformers. However, it is the practice to apply low ratio CTs based on small motor loads. The protection engineer then relies on the motor relay to trip for the enormous current of a phase-to-phase fault in the motor cable. The assumption is that fault current exceeding 300 times the CT rating can produce a secondary current large enough for a fast instantaneous trip. This leap of faith is based on the lack of knowledge of the highly distorted secondary waveform and how it is processed in the relay. The tests show the limitations of Fourier and cosine filters used in microprocessor relays that extract the fundamental phasors and eliminate harmonics. The tests validate the operation of a cosine-peak adaptive filter designed to cope with the highly distorted saturated waveforms produced by the low ratio CTs subjected to high current. This paper also reports on the results of primary high-current tests of overcurrent, motor, and distance relays using low ratio CTs. Lastly, this paper compares the internal unfiltered event records with MATLAB/spl reg/ simulations of the same cases.</description><identifier>ISBN: 0780384326</identifier><identifier>ISBN: 9780780384323</identifier><identifier>DOI: 10.1109/CPRE.2004.238491</identifier><language>eng</language><publisher>IEEE</publisher><subject>Adaptive filters ; Current measurement ; Current transformers ; Fault currents ; Microprocessors ; Power harmonic filters ; Protection ; Protective relaying ; Relays ; Testing</subject><ispartof>57th Annual Conference for Protective Relay Engineers, 2004, 2004, p.182-189</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1287093$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1287093$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Zocholl, S.E.</creatorcontrib><creatorcontrib>Mooney, J.</creatorcontrib><title>Primary high-current testing of relays with low ratio current transformers</title><title>57th Annual Conference for Protective Relay Engineers, 2004</title><addtitle>CPRE</addtitle><description>This paper serves as one of few references describing primary high-current testing of protective relays using low ratio current transformers. Accurate measurement of high-current magnitudes requires high ratio current transformers. However, it is the practice to apply low ratio CTs based on small motor loads. The protection engineer then relies on the motor relay to trip for the enormous current of a phase-to-phase fault in the motor cable. The assumption is that fault current exceeding 300 times the CT rating can produce a secondary current large enough for a fast instantaneous trip. This leap of faith is based on the lack of knowledge of the highly distorted secondary waveform and how it is processed in the relay. The tests show the limitations of Fourier and cosine filters used in microprocessor relays that extract the fundamental phasors and eliminate harmonics. The tests validate the operation of a cosine-peak adaptive filter designed to cope with the highly distorted saturated waveforms produced by the low ratio CTs subjected to high current. This paper also reports on the results of primary high-current tests of overcurrent, motor, and distance relays using low ratio CTs. Lastly, this paper compares the internal unfiltered event records with MATLAB/spl reg/ simulations of the same cases.</description><subject>Adaptive filters</subject><subject>Current measurement</subject><subject>Current transformers</subject><subject>Fault currents</subject><subject>Microprocessors</subject><subject>Power harmonic filters</subject><subject>Protection</subject><subject>Protective relaying</subject><subject>Relays</subject><subject>Testing</subject><isbn>0780384326</isbn><isbn>9780780384323</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2004</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo9jk1LAzEURQMiqLV7wU3-wIx5-c5ShqqVgkV0XTLTl05kOiNJpPTfW6h4N_csLodLyB2wGoC5h2b9vqg5Y7LmwkoHF-SGGctOLLi-IvOcv9gpUoGy6pq8rlPc-3Skfdz1VfeTEo6FFswljjs6BZpw8MdMD7H0dJgONPkSJ_o_TH7MYUp7TPmWXAY_ZJz_9Yx8Pi0-mpdq9fa8bB5XVQQjSuWkkrLzCIYbrTrjAFuUQQvRcgBotwr4FqWxTqPrOgNOt1ZqYQNzmgclZuT-7I2IuPk-_98At4Y5IX4BX11LGQ</recordid><startdate>2004</startdate><enddate>2004</enddate><creator>Zocholl, S.E.</creator><creator>Mooney, J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2004</creationdate><title>Primary high-current testing of relays with low ratio current transformers</title><author>Zocholl, S.E. ; Mooney, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i173t-94544cae172765c791ebe4f633b2111bd512de47896e9cc7196b84638f0962f53</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Adaptive filters</topic><topic>Current measurement</topic><topic>Current transformers</topic><topic>Fault currents</topic><topic>Microprocessors</topic><topic>Power harmonic filters</topic><topic>Protection</topic><topic>Protective relaying</topic><topic>Relays</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Zocholl, S.E.</creatorcontrib><creatorcontrib>Mooney, J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Zocholl, S.E.</au><au>Mooney, J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Primary high-current testing of relays with low ratio current transformers</atitle><btitle>57th Annual Conference for Protective Relay Engineers, 2004</btitle><stitle>CPRE</stitle><date>2004</date><risdate>2004</risdate><spage>182</spage><epage>189</epage><pages>182-189</pages><isbn>0780384326</isbn><isbn>9780780384323</isbn><abstract>This paper serves as one of few references describing primary high-current testing of protective relays using low ratio current transformers. Accurate measurement of high-current magnitudes requires high ratio current transformers. However, it is the practice to apply low ratio CTs based on small motor loads. The protection engineer then relies on the motor relay to trip for the enormous current of a phase-to-phase fault in the motor cable. The assumption is that fault current exceeding 300 times the CT rating can produce a secondary current large enough for a fast instantaneous trip. This leap of faith is based on the lack of knowledge of the highly distorted secondary waveform and how it is processed in the relay. The tests show the limitations of Fourier and cosine filters used in microprocessor relays that extract the fundamental phasors and eliminate harmonics. The tests validate the operation of a cosine-peak adaptive filter designed to cope with the highly distorted saturated waveforms produced by the low ratio CTs subjected to high current. This paper also reports on the results of primary high-current tests of overcurrent, motor, and distance relays using low ratio CTs. Lastly, this paper compares the internal unfiltered event records with MATLAB/spl reg/ simulations of the same cases.</abstract><pub>IEEE</pub><doi>10.1109/CPRE.2004.238491</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 0780384326 |
ispartof | 57th Annual Conference for Protective Relay Engineers, 2004, 2004, p.182-189 |
issn | |
language | eng |
recordid | cdi_ieee_primary_1287093 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Adaptive filters Current measurement Current transformers Fault currents Microprocessors Power harmonic filters Protection Protective relaying Relays Testing |
title | Primary high-current testing of relays with low ratio current transformers |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T15%3A36%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Primary%20high-current%20testing%20of%20relays%20with%20low%20ratio%20current%20transformers&rft.btitle=57th%20Annual%20Conference%20for%20Protective%20Relay%20Engineers,%202004&rft.au=Zocholl,%20S.E.&rft.date=2004&rft.spage=182&rft.epage=189&rft.pages=182-189&rft.isbn=0780384326&rft.isbn_list=9780780384323&rft_id=info:doi/10.1109/CPRE.2004.238491&rft_dat=%3Cieee_6IE%3E1287093%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i173t-94544cae172765c791ebe4f633b2111bd512de47896e9cc7196b84638f0962f53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1287093&rfr_iscdi=true |