Loading…

Study on transverse resistance and coupling losses in superconducting cables

Superconducting transposed cables with different transverse resistivities have been investigated. These cables consist of NbTi-Cu wires with different coatings. The magnitude of interwire resistance has been varied from 10/sup -3/ up to 10/sup -7/ Omega . The methods and results of measuring the tra...

Full description

Saved in:
Bibliographic Details
Published in:IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States) 1991-03, Vol.27 (2), p.2494-2498
Main Authors: Sytnikov, V.E., Svalov, G.G., Radchenko, I.P., Zlobin, A.V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Superconducting transposed cables with different transverse resistivities have been investigated. These cables consist of NbTi-Cu wires with different coatings. The magnitude of interwire resistance has been varied from 10/sup -3/ up to 10/sup -7/ Omega . The methods and results of measuring the transverse resistance and its dependence upon compression and external magnetic field are discussed. On the basis of the results obtained, the construction of the cables with the anisotropic transverse resistance providing a high stability level is proposed. The coupling losses in the cables with different transverse resistances have been measured. The proposed construction of the cables should provide reduction of coupling losses by a factor of 10/sup 2/-10/sup 3/ as compared with soldered cables.
ISSN:0018-9464
1941-0069
DOI:10.1109/20.133725