Current versus flux in the control of electromechanical valve actuators

Due to a lack of bandwidth separation, it is unclear which combination of feedback signals would be most advantageous for controlling electromechanical valve actuators. To address this issue, this paper investigates the use of position, current, and flux measurements in the feedback. Based on the an...

Full description

Saved in:
Bibliographic Details
Main Authors: Peterson, L.S., Stefanopoulou, A.G., Freudenberg, J.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Due to a lack of bandwidth separation, it is unclear which combination of feedback signals would be most advantageous for controlling electromechanical valve actuators. To address this issue, this paper investigates the use of position, current, and flux measurements in the feedback. Based on the analysis, a combination of position and flux best achieves the design specifications without incurring large control signals.