Protection scheme of cross differential relay for double transmission lines

This paper presents the development of the cross differential relay. The new relay is suitable to double circuit HV transmission lines. Based on basic principle of cross differential relay, the paper introduces a percentage cross differential current elements used to improve sensitivity of cross dif...

Full description

Saved in:
Bibliographic Details
Main Authors: Wang, Q.P., Dong, X.Z., Bo, Z.Q., Caunce, B.R.J., Tholomier, D., Apostolov, A.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 2701 Vol. 3
container_issue
container_start_page 2697
container_title
container_volume
creator Wang, Q.P.
Dong, X.Z.
Bo, Z.Q.
Caunce, B.R.J.
Tholomier, D.
Apostolov, A.
description This paper presents the development of the cross differential relay. The new relay is suitable to double circuit HV transmission lines. Based on basic principle of cross differential relay, the paper introduces a percentage cross differential current elements used to improve sensitivity of cross differential relay. To improve stability of cross differential relay, voltage elements are used to distinguish between fault and open circuit condition, and phase selector elements are used to block healthy phase elements. EMTP simulations and real time digital simulator system (RTDS) tests prove that the cross differential protection is able to offer correct responses under various system and fault conditions.
doi_str_mv 10.1109/PES.2005.1489524
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1489524</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1489524</ieee_id><sourcerecordid>1489524</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-9a1e6c2d98311b423d229ab2a7b9250267a59cd254d2265464ab4ce76442f2cd3</originalsourceid><addsrcrecordid>eNotj09LAzEUxAMqWGvvgpd8ga15L8nu5iil_sGCBfVcsskLRnY3kqyHfntXLAzMYX4zMIzdgFgDCHO3376tUQi9BtUajeqMrUzTilnSgG7UOVuAkVhpDc0luyrla4YlKFywl31OE7kpppEX90kD8RS4y6kU7mMIlGmcou15pt4eeUiZ-_TT9cSnbMcyxFL-qn0cqVyzi2D7QquTL9nHw_Z981TtXh-fN_e7KoLQU2UsUO3Qm1YCdAqlRzS2Q9t0BrXAurHaOI9azUGtVa1spxw1tVIY0Hm5ZLf_u5GIDt85DjYfD6fv8he6Sk1q</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Protection scheme of cross differential relay for double transmission lines</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Wang, Q.P. ; Dong, X.Z. ; Bo, Z.Q. ; Caunce, B.R.J. ; Tholomier, D. ; Apostolov, A.</creator><creatorcontrib>Wang, Q.P. ; Dong, X.Z. ; Bo, Z.Q. ; Caunce, B.R.J. ; Tholomier, D. ; Apostolov, A.</creatorcontrib><description>This paper presents the development of the cross differential relay. The new relay is suitable to double circuit HV transmission lines. Based on basic principle of cross differential relay, the paper introduces a percentage cross differential current elements used to improve sensitivity of cross differential relay. To improve stability of cross differential relay, voltage elements are used to distinguish between fault and open circuit condition, and phase selector elements are used to block healthy phase elements. EMTP simulations and real time digital simulator system (RTDS) tests prove that the cross differential protection is able to offer correct responses under various system and fault conditions.</description><identifier>ISSN: 1932-5517</identifier><identifier>ISBN: 9780780391574</identifier><identifier>ISBN: 0780391578</identifier><identifier>DOI: 10.1109/PES.2005.1489524</identifier><language>eng</language><publisher>IEEE</publisher><subject>Circuit faults ; Circuit simulation ; Circuit stability ; Digital relays ; Distributed parameter circuits ; EMTP ; Protection ; Protective relaying ; Transmission lines ; Voltage</subject><ispartof>IEEE Power Engineering Society General Meeting, 2005, 2005, p.2697-2701 Vol. 3</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1489524$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1489524$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Wang, Q.P.</creatorcontrib><creatorcontrib>Dong, X.Z.</creatorcontrib><creatorcontrib>Bo, Z.Q.</creatorcontrib><creatorcontrib>Caunce, B.R.J.</creatorcontrib><creatorcontrib>Tholomier, D.</creatorcontrib><creatorcontrib>Apostolov, A.</creatorcontrib><title>Protection scheme of cross differential relay for double transmission lines</title><title>IEEE Power Engineering Society General Meeting, 2005</title><addtitle>PES</addtitle><description>This paper presents the development of the cross differential relay. The new relay is suitable to double circuit HV transmission lines. Based on basic principle of cross differential relay, the paper introduces a percentage cross differential current elements used to improve sensitivity of cross differential relay. To improve stability of cross differential relay, voltage elements are used to distinguish between fault and open circuit condition, and phase selector elements are used to block healthy phase elements. EMTP simulations and real time digital simulator system (RTDS) tests prove that the cross differential protection is able to offer correct responses under various system and fault conditions.</description><subject>Circuit faults</subject><subject>Circuit simulation</subject><subject>Circuit stability</subject><subject>Digital relays</subject><subject>Distributed parameter circuits</subject><subject>EMTP</subject><subject>Protection</subject><subject>Protective relaying</subject><subject>Transmission lines</subject><subject>Voltage</subject><issn>1932-5517</issn><isbn>9780780391574</isbn><isbn>0780391578</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2005</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotj09LAzEUxAMqWGvvgpd8ga15L8nu5iil_sGCBfVcsskLRnY3kqyHfntXLAzMYX4zMIzdgFgDCHO3376tUQi9BtUajeqMrUzTilnSgG7UOVuAkVhpDc0luyrla4YlKFywl31OE7kpppEX90kD8RS4y6kU7mMIlGmcou15pt4eeUiZ-_TT9cSnbMcyxFL-qn0cqVyzi2D7QquTL9nHw_Z981TtXh-fN_e7KoLQU2UsUO3Qm1YCdAqlRzS2Q9t0BrXAurHaOI9azUGtVa1spxw1tVIY0Hm5ZLf_u5GIDt85DjYfD6fv8he6Sk1q</recordid><startdate>2005</startdate><enddate>2005</enddate><creator>Wang, Q.P.</creator><creator>Dong, X.Z.</creator><creator>Bo, Z.Q.</creator><creator>Caunce, B.R.J.</creator><creator>Tholomier, D.</creator><creator>Apostolov, A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2005</creationdate><title>Protection scheme of cross differential relay for double transmission lines</title><author>Wang, Q.P. ; Dong, X.Z. ; Bo, Z.Q. ; Caunce, B.R.J. ; Tholomier, D. ; Apostolov, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-9a1e6c2d98311b423d229ab2a7b9250267a59cd254d2265464ab4ce76442f2cd3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Circuit faults</topic><topic>Circuit simulation</topic><topic>Circuit stability</topic><topic>Digital relays</topic><topic>Distributed parameter circuits</topic><topic>EMTP</topic><topic>Protection</topic><topic>Protective relaying</topic><topic>Transmission lines</topic><topic>Voltage</topic><toplevel>online_resources</toplevel><creatorcontrib>Wang, Q.P.</creatorcontrib><creatorcontrib>Dong, X.Z.</creatorcontrib><creatorcontrib>Bo, Z.Q.</creatorcontrib><creatorcontrib>Caunce, B.R.J.</creatorcontrib><creatorcontrib>Tholomier, D.</creatorcontrib><creatorcontrib>Apostolov, A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Wang, Q.P.</au><au>Dong, X.Z.</au><au>Bo, Z.Q.</au><au>Caunce, B.R.J.</au><au>Tholomier, D.</au><au>Apostolov, A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Protection scheme of cross differential relay for double transmission lines</atitle><btitle>IEEE Power Engineering Society General Meeting, 2005</btitle><stitle>PES</stitle><date>2005</date><risdate>2005</risdate><spage>2697</spage><epage>2701 Vol. 3</epage><pages>2697-2701 Vol. 3</pages><issn>1932-5517</issn><isbn>9780780391574</isbn><isbn>0780391578</isbn><abstract>This paper presents the development of the cross differential relay. The new relay is suitable to double circuit HV transmission lines. Based on basic principle of cross differential relay, the paper introduces a percentage cross differential current elements used to improve sensitivity of cross differential relay. To improve stability of cross differential relay, voltage elements are used to distinguish between fault and open circuit condition, and phase selector elements are used to block healthy phase elements. EMTP simulations and real time digital simulator system (RTDS) tests prove that the cross differential protection is able to offer correct responses under various system and fault conditions.</abstract><pub>IEEE</pub><doi>10.1109/PES.2005.1489524</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1932-5517
ispartof IEEE Power Engineering Society General Meeting, 2005, 2005, p.2697-2701 Vol. 3
issn 1932-5517
language eng
recordid cdi_ieee_primary_1489524
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Circuit faults
Circuit simulation
Circuit stability
Digital relays
Distributed parameter circuits
EMTP
Protection
Protective relaying
Transmission lines
Voltage
title Protection scheme of cross differential relay for double transmission lines
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T21%3A11%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Protection%20scheme%20of%20cross%20differential%20relay%20for%20double%20transmission%20lines&rft.btitle=IEEE%20Power%20Engineering%20Society%20General%20Meeting,%202005&rft.au=Wang,%20Q.P.&rft.date=2005&rft.spage=2697&rft.epage=2701%20Vol.%203&rft.pages=2697-2701%20Vol.%203&rft.issn=1932-5517&rft.isbn=9780780391574&rft.isbn_list=0780391578&rft_id=info:doi/10.1109/PES.2005.1489524&rft_dat=%3Cieee_6IE%3E1489524%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i105t-9a1e6c2d98311b423d229ab2a7b9250267a59cd254d2265464ab4ce76442f2cd3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1489524&rfr_iscdi=true