Loading…

Sensorless Control of 3-Phase PWM Rectifier in Case of Grid Phase Disconnection

Standard drive systems are usually connected to the utility grid using six pulse diode rectifiers. This kind of the rectifiers has many disadvantages, for example non sinusoidal supply currents, non unity power factor, and the DC-link voltage cannot be controlled. To overcome these disadvantages the...

Full description

Saved in:
Bibliographic Details
Main Authors: Szczupak, P., Kennel, R., Boller, T.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 2022
container_issue
container_start_page 2019
container_title
container_volume
creator Szczupak, P.
Kennel, R.
Boller, T.
description Standard drive systems are usually connected to the utility grid using six pulse diode rectifiers. This kind of the rectifiers has many disadvantages, for example non sinusoidal supply currents, non unity power factor, and the DC-link voltage cannot be controlled. To overcome these disadvantages the use of controlled PWM rectifiers seems to be appropriate. There are many control schemes proposed for active rectifiers. One of the most popular schemes is the voltage oriented control (VOC) method. It is easy to implement and simple to analyze especially because of its analogy to the well-known field oriented control (FOC) for the synchronous and asynchronous drives. One of the problems connected with this method is the need for grid voltage measurement. Voltage measurement systems are costly and each failure in the measurement device can lead to the destruction of the PWM rectifier. Due to these problems voltage estimation methods often are implemented. One of the many sensorless strategies, a phase tracking concept was presented on the PESC03 conference. The method proved to be robust to system parameter changes when being used for line current control. It was also successfully tested under the distorted voltage supply like over-voltage and under-voltage. After the presentation of the respective results on the PESC04 conference some questions arose from industry concerning the behavior of the sensorless PWM rectifier when one of the grid phase voltages disrupts. This paper shows the possible solution for this particular problem. The sensitivity of the phase tracking method to the voltage phase asymmetry is also presented. The control was performed on a rapid prototype system for power electronics control according to A. Linder (2001). Experimental results of the test are presented
doi_str_mv 10.1109/PESC.2005.1581909
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1581909</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1581909</ieee_id><sourcerecordid>1581909</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-2a2f45b503d2bc323309d1762a4df8a24029742bb4ccbb79ae71adbc3938515c3</originalsourceid><addsrcrecordid>eNotkN1KxDAUhIM_YF33AcSbvEDrOTlN01xKXVdhZYureLkkbYqR2krSG9_eLrswMDB8MxfD2C1Chgj6vl7tqkwAyAxliRr0GUsEKZUWBapzttSqhFmkgQgvWAJCyVQTFFfsOsbvuUgIMmHbnRviGHoXI6_GYQpjz8eOU1p_meh4_fnK31wz-c67wP3Aq0M6A-vgW35kHn1sxmE4UONwwy4700e3PPmCfTyt3qvndLNdv1QPm9SjklMqjOhyaSVQK2xDggh0i6oQJm-70ogchFa5sDZvGmuVNk6haWdSUylRNrRgd8dd75zb_wb_Y8Lf_vQF_QM5lk9Y</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Sensorless Control of 3-Phase PWM Rectifier in Case of Grid Phase Disconnection</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Szczupak, P. ; Kennel, R. ; Boller, T.</creator><creatorcontrib>Szczupak, P. ; Kennel, R. ; Boller, T.</creatorcontrib><description>Standard drive systems are usually connected to the utility grid using six pulse diode rectifiers. This kind of the rectifiers has many disadvantages, for example non sinusoidal supply currents, non unity power factor, and the DC-link voltage cannot be controlled. To overcome these disadvantages the use of controlled PWM rectifiers seems to be appropriate. There are many control schemes proposed for active rectifiers. One of the most popular schemes is the voltage oriented control (VOC) method. It is easy to implement and simple to analyze especially because of its analogy to the well-known field oriented control (FOC) for the synchronous and asynchronous drives. One of the problems connected with this method is the need for grid voltage measurement. Voltage measurement systems are costly and each failure in the measurement device can lead to the destruction of the PWM rectifier. Due to these problems voltage estimation methods often are implemented. One of the many sensorless strategies, a phase tracking concept was presented on the PESC03 conference. The method proved to be robust to system parameter changes when being used for line current control. It was also successfully tested under the distorted voltage supply like over-voltage and under-voltage. After the presentation of the respective results on the PESC04 conference some questions arose from industry concerning the behavior of the sensorless PWM rectifier when one of the grid phase voltages disrupts. This paper shows the possible solution for this particular problem. The sensitivity of the phase tracking method to the voltage phase asymmetry is also presented. The control was performed on a rapid prototype system for power electronics control according to A. Linder (2001). Experimental results of the test are presented</description><identifier>ISSN: 0275-9306</identifier><identifier>ISBN: 9780780390331</identifier><identifier>ISBN: 0780390334</identifier><identifier>EISSN: 2377-6617</identifier><identifier>DOI: 10.1109/PESC.2005.1581909</identifier><language>eng</language><publisher>IEEE</publisher><subject>Control systems ; Current supplies ; Diodes ; Pulse width modulation ; Rectifiers ; Sensorless control ; Space vector pulse width modulation ; Testing ; Voltage control ; Voltage measurement</subject><ispartof>2005 IEEE 36th Power Electronics Specialists Conference, 2005, p.2019-2022</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1581909$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54555,54920,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1581909$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Szczupak, P.</creatorcontrib><creatorcontrib>Kennel, R.</creatorcontrib><creatorcontrib>Boller, T.</creatorcontrib><title>Sensorless Control of 3-Phase PWM Rectifier in Case of Grid Phase Disconnection</title><title>2005 IEEE 36th Power Electronics Specialists Conference</title><addtitle>PESC</addtitle><description>Standard drive systems are usually connected to the utility grid using six pulse diode rectifiers. This kind of the rectifiers has many disadvantages, for example non sinusoidal supply currents, non unity power factor, and the DC-link voltage cannot be controlled. To overcome these disadvantages the use of controlled PWM rectifiers seems to be appropriate. There are many control schemes proposed for active rectifiers. One of the most popular schemes is the voltage oriented control (VOC) method. It is easy to implement and simple to analyze especially because of its analogy to the well-known field oriented control (FOC) for the synchronous and asynchronous drives. One of the problems connected with this method is the need for grid voltage measurement. Voltage measurement systems are costly and each failure in the measurement device can lead to the destruction of the PWM rectifier. Due to these problems voltage estimation methods often are implemented. One of the many sensorless strategies, a phase tracking concept was presented on the PESC03 conference. The method proved to be robust to system parameter changes when being used for line current control. It was also successfully tested under the distorted voltage supply like over-voltage and under-voltage. After the presentation of the respective results on the PESC04 conference some questions arose from industry concerning the behavior of the sensorless PWM rectifier when one of the grid phase voltages disrupts. This paper shows the possible solution for this particular problem. The sensitivity of the phase tracking method to the voltage phase asymmetry is also presented. The control was performed on a rapid prototype system for power electronics control according to A. Linder (2001). Experimental results of the test are presented</description><subject>Control systems</subject><subject>Current supplies</subject><subject>Diodes</subject><subject>Pulse width modulation</subject><subject>Rectifiers</subject><subject>Sensorless control</subject><subject>Space vector pulse width modulation</subject><subject>Testing</subject><subject>Voltage control</subject><subject>Voltage measurement</subject><issn>0275-9306</issn><issn>2377-6617</issn><isbn>9780780390331</isbn><isbn>0780390334</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2005</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkN1KxDAUhIM_YF33AcSbvEDrOTlN01xKXVdhZYureLkkbYqR2krSG9_eLrswMDB8MxfD2C1Chgj6vl7tqkwAyAxliRr0GUsEKZUWBapzttSqhFmkgQgvWAJCyVQTFFfsOsbvuUgIMmHbnRviGHoXI6_GYQpjz8eOU1p_meh4_fnK31wz-c67wP3Aq0M6A-vgW35kHn1sxmE4UONwwy4700e3PPmCfTyt3qvndLNdv1QPm9SjklMqjOhyaSVQK2xDggh0i6oQJm-70ogchFa5sDZvGmuVNk6haWdSUylRNrRgd8dd75zb_wb_Y8Lf_vQF_QM5lk9Y</recordid><startdate>2005</startdate><enddate>2005</enddate><creator>Szczupak, P.</creator><creator>Kennel, R.</creator><creator>Boller, T.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2005</creationdate><title>Sensorless Control of 3-Phase PWM Rectifier in Case of Grid Phase Disconnection</title><author>Szczupak, P. ; Kennel, R. ; Boller, T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-2a2f45b503d2bc323309d1762a4df8a24029742bb4ccbb79ae71adbc3938515c3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Control systems</topic><topic>Current supplies</topic><topic>Diodes</topic><topic>Pulse width modulation</topic><topic>Rectifiers</topic><topic>Sensorless control</topic><topic>Space vector pulse width modulation</topic><topic>Testing</topic><topic>Voltage control</topic><topic>Voltage measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Szczupak, P.</creatorcontrib><creatorcontrib>Kennel, R.</creatorcontrib><creatorcontrib>Boller, T.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Szczupak, P.</au><au>Kennel, R.</au><au>Boller, T.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Sensorless Control of 3-Phase PWM Rectifier in Case of Grid Phase Disconnection</atitle><btitle>2005 IEEE 36th Power Electronics Specialists Conference</btitle><stitle>PESC</stitle><date>2005</date><risdate>2005</risdate><spage>2019</spage><epage>2022</epage><pages>2019-2022</pages><issn>0275-9306</issn><eissn>2377-6617</eissn><isbn>9780780390331</isbn><isbn>0780390334</isbn><abstract>Standard drive systems are usually connected to the utility grid using six pulse diode rectifiers. This kind of the rectifiers has many disadvantages, for example non sinusoidal supply currents, non unity power factor, and the DC-link voltage cannot be controlled. To overcome these disadvantages the use of controlled PWM rectifiers seems to be appropriate. There are many control schemes proposed for active rectifiers. One of the most popular schemes is the voltage oriented control (VOC) method. It is easy to implement and simple to analyze especially because of its analogy to the well-known field oriented control (FOC) for the synchronous and asynchronous drives. One of the problems connected with this method is the need for grid voltage measurement. Voltage measurement systems are costly and each failure in the measurement device can lead to the destruction of the PWM rectifier. Due to these problems voltage estimation methods often are implemented. One of the many sensorless strategies, a phase tracking concept was presented on the PESC03 conference. The method proved to be robust to system parameter changes when being used for line current control. It was also successfully tested under the distorted voltage supply like over-voltage and under-voltage. After the presentation of the respective results on the PESC04 conference some questions arose from industry concerning the behavior of the sensorless PWM rectifier when one of the grid phase voltages disrupts. This paper shows the possible solution for this particular problem. The sensitivity of the phase tracking method to the voltage phase asymmetry is also presented. The control was performed on a rapid prototype system for power electronics control according to A. Linder (2001). Experimental results of the test are presented</abstract><pub>IEEE</pub><doi>10.1109/PESC.2005.1581909</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0275-9306
ispartof 2005 IEEE 36th Power Electronics Specialists Conference, 2005, p.2019-2022
issn 0275-9306
2377-6617
language eng
recordid cdi_ieee_primary_1581909
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Control systems
Current supplies
Diodes
Pulse width modulation
Rectifiers
Sensorless control
Space vector pulse width modulation
Testing
Voltage control
Voltage measurement
title Sensorless Control of 3-Phase PWM Rectifier in Case of Grid Phase Disconnection
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T11%3A21%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Sensorless%20Control%20of%203-Phase%20PWM%20Rectifier%20in%20Case%20of%20Grid%20Phase%20Disconnection&rft.btitle=2005%20IEEE%2036th%20Power%20Electronics%20Specialists%20Conference&rft.au=Szczupak,%20P.&rft.date=2005&rft.spage=2019&rft.epage=2022&rft.pages=2019-2022&rft.issn=0275-9306&rft.eissn=2377-6617&rft.isbn=9780780390331&rft.isbn_list=0780390334&rft_id=info:doi/10.1109/PESC.2005.1581909&rft_dat=%3Cieee_6IE%3E1581909%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-2a2f45b503d2bc323309d1762a4df8a24029742bb4ccbb79ae71adbc3938515c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1581909&rfr_iscdi=true