The purpose of this study is to evaluate the performance of four block-iterative algorithms, ordered-subsets expectation-maximization (OS-EM), rescaled block-iterative EM (RBI-EM), modified row-action maximum likelihood algorithm (RAMLA) and rescaled block-iterative maximum a posteriori EM (RBI-MAP-...

Full description

Saved in:
Bibliographic Details
Main Authors: Chi Liu, Volokh, L., Xide Zhao, Jingyan Xu, Taek-Soo Lee, Tsui, B.M.W.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1831
container_issue
container_start_page 5 pp.
container_title
container_volume 3
creator Chi Liu
Volokh, L.
Xide Zhao
Jingyan Xu
Taek-Soo Lee
Tsui, B.M.W.
description The purpose of this study is to evaluate the performance of four block-iterative algorithms, ordered-subsets expectation-maximization (OS-EM), rescaled block-iterative EM (RBI-EM), modified row-action maximum likelihood algorithm (RAMLA) and rescaled block-iterative maximum a posteriori EM (RBI-MAP-EM), for In-111 ProstaScint/spl reg/ SPECT image reconstruction. The 3D NCAT phantom with realistic In-111 ProstaScint/spl reg/ activity distribution was used in the study. Noise-free and noisy projections of the phantom obtained using a medium-energy general-purpose (MEGP) collimator were generated using Monte Carlo simulation methods. For each algorithm, the projection data were reconstructed with the compensations for attenuation, collimator-detector response and scatter. Image quality was evaluated in terms of FWHM of a profile through a small blood vessel, normalized mean square error (NMSE), ensemble normalized standard deviation (NSDE) of a uniform region of interest (ROI) in the reconstructed image measured from 30 noise realizations, and regional NSD (NSDR) of an ROI measure from 1 noise realization. The results indicated that, RBI-EM has superior performance than that of OS-EM when less than 4 views per subset were used and similar performance when 4 or more views per subset were used. Modified RAMLA provides similar image quality with a slower convergence rate than that of OS-EM. Using well-chosen parameters, RBI-MAP-EM provides increased noise smoothing with less loss in resolution and error. We conclude that when compared with OS-EM, the RBI-EM and modified RAMLA have the same performance at a slower convergence rate, while the RBI-MAP-EM has superior performance and can potentially improve image quality.
doi_str_mv 10.1109/NSSMIC.2005.1596676
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1596676</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1596676</ieee_id><sourcerecordid>1596676</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-9c11c4727e825999b04849f9d94627882f587e4d7ff42596922032dbe0334ee53</originalsourceid><addsrcrecordid>eNotkNtKw0AYhBcPYFt9gt7sC2z895TdvZRQtdBqIfW65PCvRpOsbNKCb2_EXg0M8w3MELLkkHAO7v4lz7frLBEAOuHapalJL8hMaGMYWOEuyRyMBemE4PKKzPhkMplqdUPmw_AJIEAqNSPbHUYfYlf0FVI8Fe2xGJvQ0-Bp2YbqizUjxsk6IS3a9xCb8aMb6ETQfLfK9jRiFfphjMfqD7sl175oB7w764K8Pa722TPbvD6ts4cNa7jRI3MV55UywqAV2jlXgrLKeVc7lQpjrfDaGlS18V5NgXQaAVLUJYKUClHLBVn-9zaIePiOTVfEn8P5BvkLnThPfQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Performance evaluation of block-iterative algorithms for SPECT reconstruction</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Chi Liu ; Volokh, L. ; Xide Zhao ; Jingyan Xu ; Taek-Soo Lee ; Tsui, B.M.W.</creator><creatorcontrib>Chi Liu ; Volokh, L. ; Xide Zhao ; Jingyan Xu ; Taek-Soo Lee ; Tsui, B.M.W.</creatorcontrib><description>The purpose of this study is to evaluate the performance of four block-iterative algorithms, ordered-subsets expectation-maximization (OS-EM), rescaled block-iterative EM (RBI-EM), modified row-action maximum likelihood algorithm (RAMLA) and rescaled block-iterative maximum a posteriori EM (RBI-MAP-EM), for In-111 ProstaScint/spl reg/ SPECT image reconstruction. The 3D NCAT phantom with realistic In-111 ProstaScint/spl reg/ activity distribution was used in the study. Noise-free and noisy projections of the phantom obtained using a medium-energy general-purpose (MEGP) collimator were generated using Monte Carlo simulation methods. For each algorithm, the projection data were reconstructed with the compensations for attenuation, collimator-detector response and scatter. Image quality was evaluated in terms of FWHM of a profile through a small blood vessel, normalized mean square error (NMSE), ensemble normalized standard deviation (NSDE) of a uniform region of interest (ROI) in the reconstructed image measured from 30 noise realizations, and regional NSD (NSDR) of an ROI measure from 1 noise realization. The results indicated that, RBI-EM has superior performance than that of OS-EM when less than 4 views per subset were used and similar performance when 4 or more views per subset were used. Modified RAMLA provides similar image quality with a slower convergence rate than that of OS-EM. Using well-chosen parameters, RBI-MAP-EM provides increased noise smoothing with less loss in resolution and error. We conclude that when compared with OS-EM, the RBI-EM and modified RAMLA have the same performance at a slower convergence rate, while the RBI-MAP-EM has superior performance and can potentially improve image quality.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 0780392213</identifier><identifier>ISBN: 9780780392212</identifier><identifier>EISSN: 2577-0829</identifier><identifier>DOI: 10.1109/NSSMIC.2005.1596676</identifier><language>eng</language><publisher>IEEE</publisher><subject>Attenuation ; Blood vessels ; Collimators ; Convergence ; Image quality ; Image reconstruction ; Imaging phantoms ; Noise generators ; Noise measurement ; Scattering</subject><ispartof>IEEE Nuclear Science Symposium Conference Record, 2005, 2005, Vol.3, p.5 pp.-1831</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1596676$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54555,54920,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1596676$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Chi Liu</creatorcontrib><creatorcontrib>Volokh, L.</creatorcontrib><creatorcontrib>Xide Zhao</creatorcontrib><creatorcontrib>Jingyan Xu</creatorcontrib><creatorcontrib>Taek-Soo Lee</creatorcontrib><creatorcontrib>Tsui, B.M.W.</creatorcontrib><title>Performance evaluation of block-iterative algorithms for SPECT reconstruction</title><title>IEEE Nuclear Science Symposium Conference Record, 2005</title><addtitle>NSSMIC</addtitle><description>The purpose of this study is to evaluate the performance of four block-iterative algorithms, ordered-subsets expectation-maximization (OS-EM), rescaled block-iterative EM (RBI-EM), modified row-action maximum likelihood algorithm (RAMLA) and rescaled block-iterative maximum a posteriori EM (RBI-MAP-EM), for In-111 ProstaScint/spl reg/ SPECT image reconstruction. The 3D NCAT phantom with realistic In-111 ProstaScint/spl reg/ activity distribution was used in the study. Noise-free and noisy projections of the phantom obtained using a medium-energy general-purpose (MEGP) collimator were generated using Monte Carlo simulation methods. For each algorithm, the projection data were reconstructed with the compensations for attenuation, collimator-detector response and scatter. Image quality was evaluated in terms of FWHM of a profile through a small blood vessel, normalized mean square error (NMSE), ensemble normalized standard deviation (NSDE) of a uniform region of interest (ROI) in the reconstructed image measured from 30 noise realizations, and regional NSD (NSDR) of an ROI measure from 1 noise realization. The results indicated that, RBI-EM has superior performance than that of OS-EM when less than 4 views per subset were used and similar performance when 4 or more views per subset were used. Modified RAMLA provides similar image quality with a slower convergence rate than that of OS-EM. Using well-chosen parameters, RBI-MAP-EM provides increased noise smoothing with less loss in resolution and error. We conclude that when compared with OS-EM, the RBI-EM and modified RAMLA have the same performance at a slower convergence rate, while the RBI-MAP-EM has superior performance and can potentially improve image quality.</description><subject>Attenuation</subject><subject>Blood vessels</subject><subject>Collimators</subject><subject>Convergence</subject><subject>Image quality</subject><subject>Image reconstruction</subject><subject>Imaging phantoms</subject><subject>Noise generators</subject><subject>Noise measurement</subject><subject>Scattering</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>0780392213</isbn><isbn>9780780392212</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2005</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkNtKw0AYhBcPYFt9gt7sC2z895TdvZRQtdBqIfW65PCvRpOsbNKCb2_EXg0M8w3MELLkkHAO7v4lz7frLBEAOuHapalJL8hMaGMYWOEuyRyMBemE4PKKzPhkMplqdUPmw_AJIEAqNSPbHUYfYlf0FVI8Fe2xGJvQ0-Bp2YbqizUjxsk6IS3a9xCb8aMb6ETQfLfK9jRiFfphjMfqD7sl175oB7w764K8Pa722TPbvD6ts4cNa7jRI3MV55UywqAV2jlXgrLKeVc7lQpjrfDaGlS18V5NgXQaAVLUJYKUClHLBVn-9zaIePiOTVfEn8P5BvkLnThPfQ</recordid><startdate>2005</startdate><enddate>2005</enddate><creator>Chi Liu</creator><creator>Volokh, L.</creator><creator>Xide Zhao</creator><creator>Jingyan Xu</creator><creator>Taek-Soo Lee</creator><creator>Tsui, B.M.W.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>2005</creationdate><title>Performance evaluation of block-iterative algorithms for SPECT reconstruction</title><author>Chi Liu ; Volokh, L. ; Xide Zhao ; Jingyan Xu ; Taek-Soo Lee ; Tsui, B.M.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-9c11c4727e825999b04849f9d94627882f587e4d7ff42596922032dbe0334ee53</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Attenuation</topic><topic>Blood vessels</topic><topic>Collimators</topic><topic>Convergence</topic><topic>Image quality</topic><topic>Image reconstruction</topic><topic>Imaging phantoms</topic><topic>Noise generators</topic><topic>Noise measurement</topic><topic>Scattering</topic><toplevel>online_resources</toplevel><creatorcontrib>Chi Liu</creatorcontrib><creatorcontrib>Volokh, L.</creatorcontrib><creatorcontrib>Xide Zhao</creatorcontrib><creatorcontrib>Jingyan Xu</creatorcontrib><creatorcontrib>Taek-Soo Lee</creatorcontrib><creatorcontrib>Tsui, B.M.W.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Chi Liu</au><au>Volokh, L.</au><au>Xide Zhao</au><au>Jingyan Xu</au><au>Taek-Soo Lee</au><au>Tsui, B.M.W.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Performance evaluation of block-iterative algorithms for SPECT reconstruction</atitle><btitle>IEEE Nuclear Science Symposium Conference Record, 2005</btitle><stitle>NSSMIC</stitle><date>2005</date><risdate>2005</risdate><volume>3</volume><spage>5 pp.</spage><epage>1831</epage><pages>5 pp.-1831</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>0780392213</isbn><isbn>9780780392212</isbn><abstract>The purpose of this study is to evaluate the performance of four block-iterative algorithms, ordered-subsets expectation-maximization (OS-EM), rescaled block-iterative EM (RBI-EM), modified row-action maximum likelihood algorithm (RAMLA) and rescaled block-iterative maximum a posteriori EM (RBI-MAP-EM), for In-111 ProstaScint/spl reg/ SPECT image reconstruction. The 3D NCAT phantom with realistic In-111 ProstaScint/spl reg/ activity distribution was used in the study. Noise-free and noisy projections of the phantom obtained using a medium-energy general-purpose (MEGP) collimator were generated using Monte Carlo simulation methods. For each algorithm, the projection data were reconstructed with the compensations for attenuation, collimator-detector response and scatter. Image quality was evaluated in terms of FWHM of a profile through a small blood vessel, normalized mean square error (NMSE), ensemble normalized standard deviation (NSDE) of a uniform region of interest (ROI) in the reconstructed image measured from 30 noise realizations, and regional NSD (NSDR) of an ROI measure from 1 noise realization. The results indicated that, RBI-EM has superior performance than that of OS-EM when less than 4 views per subset were used and similar performance when 4 or more views per subset were used. Modified RAMLA provides similar image quality with a slower convergence rate than that of OS-EM. Using well-chosen parameters, RBI-MAP-EM provides increased noise smoothing with less loss in resolution and error. We conclude that when compared with OS-EM, the RBI-EM and modified RAMLA have the same performance at a slower convergence rate, while the RBI-MAP-EM has superior performance and can potentially improve image quality.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2005.1596676</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof IEEE Nuclear Science Symposium Conference Record, 2005, 2005, Vol.3, p.5 pp.-1831
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_1596676
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Attenuation
Blood vessels
Collimators
Convergence
Image quality
Image reconstruction
Imaging phantoms
Noise generators
Noise measurement
Scattering
title Performance evaluation of block-iterative algorithms for SPECT reconstruction
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T12%3A32%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Performance%20evaluation%20of%20block-iterative%20algorithms%20for%20SPECT%20reconstruction&rft.btitle=IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record,%202005&rft.au=Chi%20Liu&rft.date=2005&rft.volume=3&rft.spage=5%20pp.&rft.epage=1831&rft.pages=5%20pp.-1831&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=0780392213&rft.isbn_list=9780780392212&rft_id=info:doi/10.1109/NSSMIC.2005.1596676&rft_dat=%3Cieee_6IE%3E1596676%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-9c11c4727e825999b04849f9d94627882f587e4d7ff42596922032dbe0334ee53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1596676&rfr_iscdi=true