Dynamic single-unit representation of induction motor groups

The paper describes a method of representing a group of induction motor loads by a single-unit equivalent. The dynamic performance of the composite group following supply disturbances is examined using the single unit model. The representation employs the induction motor steady state equivalent circ...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on power apparatus and systems 1976-01, Vol.95 (1), p.155-165
Main Authors: Abdel Hakim, M.M., Berg, G.J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The paper describes a method of representing a group of induction motor loads by a single-unit equivalent. The dynamic performance of the composite group following supply disturbances is examined using the single unit model. The representation employs the induction motor steady state equivalent circuit mad allows for effects of inertia and mechanical load characteristics. Experimental results are presented and compared with corresponding theoretical results using the proposed method as well as classical techniques of analysis. Sudden and gradual supply disturbances are considered, and different load torque-speed characteristics.
ISSN:0018-9510
2995-6323
DOI:10.1109/T-PAS.1976.32088